Midterm Outcomes of the Dissected Aorta Repair Through Stent Implantation Trial.

Sabin J Bozso1, Jeevan Nagendran1, Michael W A Chu2, Bob Kiaii2, Ismail El-Hamamsy3, Maral Ouzounian4, Jörg Kempfert5, Christoph Starck5, Michael C Moon6.   

Abstract

BACKGROUND: The intimal flap at the distal aortic anastomosis after standard aortic dissection repair creates distal anastomotic new entry, leading to false lumen (FL) pressurization and true lumen (TL) collapse and resulting in increased mortality, malperfusion, aortic growth, and reinterventions. The Ascyrus Medical Dissection Stent (AMDS; Ascyrus Medical, Boca Raton, FL) is a hybrid prosthesis that seals and depressurizes the FL at the distal anastomosis while expanding and pressurizing the TL.
METHODS: The Dissected Aorta Repair Through Stent Implantation trial is a prospective, nonrandomized, international type A dissection trial where patients with acute DeBakey I dissections were enrolled between March 2017 and January 2019. Forty-seven patients were enrolled (median age, 62.5; 67.4% men) with a median follow-up of 631 days.
RESULTS: All patients underwent emergent surgical repair with successful AMDS implantation. One patient was excluded because of use in iatrogenic dissection. Overall mortality at 30 days and 1 year was 13.0% (6/46) and 19.6% (9/46), whereas new strokes occurred in 6.5% (3/46). Over 95% of vessel malperfusions resolved because of AMDS-induced TL expansion, including 3 patients with preoperative paralysis. Positive remodeling of the aortic arch occurred in 100% of cases with complete obliteration or thrombosis of the FL in 74%. In the proximal descending thoracic aorta positive remodeling occurred in 77% and complete obliteration or FL thrombosis in 53% of cases.
CONCLUSIONS: AMDS facilitates single-stage management of malperfusion and induces positive remodeling of the aortic arch through effective sealing of the distal anastomotic FL, depressurization of the FL with expansion, and pressurization of the TL. Importantly the use of AMDS is safe and reproducible.
Copyright © 2021 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2020        PMID: 32673661     DOI: 10.1016/j.athoracsur.2020.05.090

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Estimation of Value-Based Price for Five High-Technology Medical Devices Approved by a Regional Health Technology Assessment Committee in Italy.

Authors:  Andrea Messori; Sabrina Trippoli
Journal:  Cureus       Date:  2022-05-03

2.  Commentary: Beyond distal anastomosis new entry: Distal re-entry tears as well.

Authors:  Thomas M Beaver; Prashanth Vallabhajosyula
Journal:  JTCVS Tech       Date:  2021-06-23

3.  Early Results of a Novel Hybrid Prosthesis for Treatment of Acute Aortic Dissection Type A With Distal Anastomosis Line Beyond Aortic Arch Zone Zero.

Authors:  Arash Mehdiani; Yukiharu Sugimura; Louise Wollgarten; Moritz Benjamin Immohr; Sebastian Bauer; Hubert Schelzig; Markus Udo Wagenhäuser; Gerald Antoch; Artur Lichtenberg; Payam Akhyari
Journal:  Front Cardiovasc Med       Date:  2022-07-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.