Five-Year, Prospective, Randomized, Multi-Surgeon Trial of Two Trabecular Bypass Stents versus Prostaglandin for Newly Diagnosed Open-Angle Glaucoma.

Robert D Fechtner1, Lilit Voskanyan2, Steven D Vold3, Manfred Tetz4, Gerd Auffarth5, Imran Masood6, Leon Au7, Albert S Khouri8, Iqbal Ike K Ahmed9, Hady Saheb10.   

Abstract

PURPOSE: To evaluate 5-year safety and efficacy of 2 trabecular micro-bypass stents versus prostaglandin as initial stand-alone treatment for newly diagnosed, treatment-naive primary open-angle glaucoma (POAG).
DESIGN: Prospective, randomized, controlled, multi-surgeon clinical trial. PARTICIPANTS: Enrolled eyes (n = 101) were phakic and had a confirmed POAG diagnosis, normal angle anatomy, mean diurnal intraocular pressure (IOP) 21 to 40 mmHg, and vertical cup-to-disc (C:D) ratio ≤0.9.
METHODS: Eyes were randomized (1:1) to receive either 2 stents (iStent trabecular micro-bypass; Glaukos Corporation, San Clemente, CA) or once-daily topical travoprost. MAIN OUTCOME MEASURES: The primary and secondary efficacy end points were the change from screening in mean diurnal IOP at months 12 and 24, respectively, without glaucoma surgery or add-on medication (any medication in stent eyes or a second medication in travoprost eyes). Two additional secondary end points were the proportion of eyes achieving treatment success at months 12 and 24, defined as IOP 6 to 18 mmHg without additional medication or glaucoma surgery. This report shows these efficacy measures through 60 months. Safety measures included best-corrected visual acuity, C:D ratio, visual field, pachymetry, complications, and adverse events.
RESULTS: Of 101 enrolled eyes (54 stent eyes, 47 travoprost eyes), 90 eyes (49 stent eyes, 41 travoprost eyes) completed 5-year follow-up. Five-year mean diurnal IOP was 16.5±1.2 mmHg in stent eyes (35.3% reduced vs. 25.5±2.5 mmHg preoperatively; P < 0.0001) and 16.3±1.9 mmHg in travoprost eyes (35.1% reduced vs. 25.1±4.6 mmHg preoperatively; P < 0.0001). During follow-up, add-on medication was initiated in 12 stent eyes (22.2% of the initial 54-eyes) and 18 travoprost eyes (38.3% of the initial 47-eyes). By 5 years, 17% (6/35) of stent eyes and 44% (14/32) of travoprost eyes needed add-on medication to control IOP (P = 0.017). Treatment success was achieved in 77% (27/35) of stent eyes and 53% (17/32) of travoprost eyes (P = 0.04). Both groups exhibited excellent safety.
CONCLUSIONS: This prospective randomized trial demonstrates 5-year effectiveness and safety of 2 trabecular bypass stents in patients with newly diagnosed, treatment-naive POAG, with comparably favorable outcomes as topical prostaglandin.
Copyright © 2019 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2019        PMID: 32672584     DOI: 10.1016/j.ogla.2019.03.004

Source DB:  PubMed          Journal:  Ophthalmol Glaucoma        ISSN: 2589-4196


  11 in total

1.  iStent for Adults With Glaucoma: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2021-07-21

2.  Two-Year Multicenter Outcomes of iStent inject Trabecular Micro-Bypass Stents Combined with Phacoemulsification in Various Types of Glaucoma and Ocular Hypertension.

Authors:  Colin Clement; Frank Howes; Alexandros S Ioannidis; Michael Shiu; David Manning; Jed Lusthaus; Ridia Lim; Simon E Skalicky; Todd Goodwin
Journal:  Clin Ophthalmol       Date:  2020-10-28

3.  iStent Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in a Japanese Glaucoma Population.

Authors:  Koji Nitta; Yutaro Yamada; Satomi Morokado; Kazuhisa Sugiyama
Journal:  Clin Ophthalmol       Date:  2020-10-15

4.  Two-Year Comparative Outcomes of First- and Second-Generation Trabecular Micro-Bypass Stents with Cataract Surgery.

Authors:  Ricardo Augusto Paletta Guedes; Daniela Marcelo Gravina; Vanessa Maria Paletta Guedes; Alfredo Chaoubah
Journal:  Clin Ophthalmol       Date:  2021-05-05

5.  Second-Generation Trabecular Micro-Bypass (iStent inject) with Cataract Surgery in Eyes with Normal-Tension Glaucoma: One-Year Outcomes of a Multi-Centre Study.

Authors:  Ali Salimi; Colin Clement; Michael Shiu; Paul Harasymowycz
Journal:  Ophthalmol Ther       Date:  2020-07-01

6.  One-Year Outcomes of Second-Generation Trabecular Micro-Bypass Stents (iStent Inject) Implantation with Cataract Surgery in Different Glaucoma Subtypes and Severities.

Authors:  Ali Salimi; Julie Lapointe; Paul Harasymowycz
Journal:  Ophthalmol Ther       Date:  2019-09-19

7.  Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery.

Authors:  David Manning
Journal:  Ophthalmol Ther       Date:  2019-08-17

8.  Standalone Implantation of 2-3 Trabecular Micro-Bypass Stents (iStent inject ± iStent) as an Alternative to Trabeculectomy for Moderate-to-Severe Glaucoma.

Authors:  Ricardo Augusto Paletta Guedes; Daniela Marcelo Gravina; Vanessa Maria Paletta Guedes; Alfredo Chaoubah
Journal:  Ophthalmol Ther       Date:  2021-11-25

9.  Treatment Success Across Different Levels of Preoperative Disease Burden: Stratified Two-Year Outcomes from the Pivotal Trial of iStent inject ® Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract.

Authors:  Inder Paul Singh; Steven Sarkisian; Dana Hornbeak; L Jay Katz; Thomas Samuelson
Journal:  Clin Ophthalmol       Date:  2021-08-03

10.  Surgical Outcomes of Combined 2nd-Generation Trabecular Microbypass (iStent Inject) and Cataract Surgery for the Treatment of Primary Open-Angle Glaucoma in the Saudi Population.

Authors:  Ahmed Al Habash; Wael Otaif
Journal:  Ophthalmol Ther       Date:  2021-08-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.