Literature DB >> 32672249

Ultraviolet-visible diffuse reflectance spectroscopy combined with chemometrics for rapid discrimination of Angelicae Sinensis Radix from its four similar herbs.

Xihui Bian1, Zhankui Lu2, Geert van Kollenburg3.   

Abstract

Ultraviolet-visible diffuse reflectance spectroscopy (UV-Vis DRS) combined with chemometrics was used for the first time to differentiate Angelicae Sinensis Radix (ASR) from four other similar herbs (either from the same genus or of similar appearance). A total of 191 samples, including 40 ASR, 39 Angelicae Pubescentis Radix (APR), 38 Chuanxiong Rhizoma (CR), 35 Atractylodis Macrocephalae Rhizoma (AMR) and 39 Angelicae Dahuricae Radix (ADR), were collected and divided into the training and prediction sets. Principal component analysis (PCA) was used for observing the sample cluster tendency of the calibration set. Different preprocessing methods were investigated and the optimal preprocessing combination was selected according to spectral signal characteristics and three-dimensional PCA (3D PCA) clustering results. The final discriminant model was built using extreme learning machine (ELM). The exploratory studies on the raw spectra and their 3D PCA scores indicate that the classification of the five herbs cannot be achieved by PCA of the raw spectra. Autoscaling, continuous wavelet transform (CWT) and Savitzky-Golay (SG) smoothing can improve the clustering results to different degrees. Furthermore, their combination in the order of CWT + autoscaling + SG smoothing can enhance the spectral resolution and obtain the best clustering result. These results are also validated using ELM models of raw and different preprocessing methods. By using CWT + autoscaling + SG smoothing + ELM, 100% classification accuracy can be achieved in both the calibration set and the prediction set. Therefore, the developed method could be used as a rapid, economic and effective method for discriminating the five herbs used in this study.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32672249     DOI: 10.1039/d0ay00285b

Source DB:  PubMed          Journal:  Anal Methods        ISSN: 1759-9660            Impact factor:   2.896


  2 in total

1.  Accurate identification of kidney injury progression via a fluorescent biosensor array.

Authors:  Xie-An Yu; Lei Zhang; Ran Zhang; Xuefei Bai; Ying Zhang; Yiting Hu; Yang Wu; Ziyi Li; Bing Wang; Jiangwei Tian
Journal:  Mikrochim Acta       Date:  2022-08-01       Impact factor: 6.408

2.  Variational Mode Decomposition Weighted Multiscale Support Vector Regression for Spectral Determination of Rapeseed Oil and Rhizoma Alpiniae Offcinarum Adulterants.

Authors:  Xihui Bian; Deyun Wu; Kui Zhang; Peng Liu; Huibing Shi; Xiaoyao Tan; Zhigang Wang
Journal:  Biosensors (Basel)       Date:  2022-08-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.