Powered Air Purifying Respirators (PAPR) for the protection of surgeons during operative tasks: a user perspective assessment.

J Dalli1, D A O'Keeffe1, F Khan1, O Traynor1, R A Cahill1.   

Abstract

Entities:  

Year:  2020        PMID: 32671824      PMCID: PMC7405207          DOI: 10.1002/bjs.11782

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


× No keyword cloud information.
Editor The unfolding COVID‐19 pandemic has challenged surgical care where aerosol‐generating operations may expose the surgical team , , . Optimization of theatre airflow management and the application of smoke evacuation devices have been recommended and some personal protective equipment may remain for the foreseeable future , , . WHO guidelines advise well‐fitting respirators (for example FFP2/3 or N95 masks) for surgical teams as the minimum where there is exposure risk. These disposable masks are becoming scarce and may not offer the required protection especially when poorly fitted. Powered Air Purifying Respirators (PAPR) are another type of respiratory protection that are validated to offer higher respiratory protection by regulatory bodies (2·5‐100x Airway Protection Factor versus N95 masks). These respirators feature a waist‐mounted battery‐powered pump that blows filtered air into a hood and are reusable. These devices are widely used in other industries but haven't been formally assessed for operating room teams. Photographs showing (a) the two mask types (FH1 and FH2, both with soft‐head cradles, neoprene chin seals and clear full‐face visors with down‐view panels certified to EN12941 TH3, EN166 1F) as well as PAPR use in simulated settings. Participants (b) scrubbing, (c) performing laparoscopic box tasks both individually and in pairs and (c) in full team operating room simulation. Mean values (± SD) for measured subjective perception scores (average of all readings) including by clinical role. FH1 denotes half mask while FH2 denotes full mask. Surg denotes surgeons and anaes denotes Anaesthesiologists. P values indicate statistical differences between combined means between masks (Mann–Whitney U test) and between clinical roles (Kruskal‐Wallis test) Statistically significant results (P < 0·05). Statistically significant P value (Mann–Whitney U test) for surgeons versus nurses with respect to thermal sensation score and for surgeons versus anaesthesiologists for perception of breathing. As part of a validation exercise, a frontline clinical user perspective assessment was performed of donated PAPR under operating conditions in high‐fidelity simulation environments. Scott Tornado (3 M) PAPR with both half (FH1) and full (FH2) hoods was tested by 46 clinicians (36 surgeons, six anaesthetists and four nurses) without prior PAPR experience in elective and emergency general surgery (open and laparoscopy), plastics and reconstructive surgery and head and neck/dental surgery simulations with subjective and objective evaluation. Initially, surgeons in PAPR carried out both laparoscopic and open tasks individually and in pairs including simulated minimal access appendicectomy and porcine laparotomy (involving splenectomy, cholecystectomy and bowel resection/anastomosis) over 90‐120 mins. Thereafter, complete operative SIM‐MAN simulation was performed with four full specialty teams all wearing PAPR, specifically laparoscopic appendectomies (two teams), tracheostomy and cleft palate repair with dental extraction (Fig. 1). Subjective confidence, comfort and communications scores were collected at fixed intervals using established, adopted and designed methodology ( ). Collaborative team working was also assessed objectively, including an unexpected challenge during scenarios by planned telephone interruption. Social distancing was observed. PAPR was well accepted regardless of hood type and all tasks were completed within the allocated time (Table 1). There was no temporal deterioration of scores. Confidence in PAPR use significantly improved after assessment (postop median score of 4/5 versus 3 pre‐test, P = 0·002, Sign Test). FH1 hoods scored best for comfort and communication. Surgeons reported less heat and breathing impact than anaesthesiologists and nurses. Qualitative comments were generally positive with users feeling ‘protected’ and ‘safe’. Pumps alarmed when gowns obstructed the inflow and the fixed length tubing impacted shorter individuals' gowning and teams spatially with respect to sterility but these were manageable. Conventional stethoscopes and loupes could not be used. Alongside ongoing emergency and time‐critical surgery, surgical services now need resumption including address of the ‘third wave’ of procedure backlog. PAPR may be fit for surgical settings if needed with local approval and adequate training.

Conflicts of Interest

None of the authors have conflicts of interest directly related to this study. RC receives speaker fees from Stryker Corp, consultancy payments from Distalmotion and Touch Surgery and holds research funding from Intuitive Surgery and with IBM. Appendix S1. Supplementary Data: Study protocol and details of each subjective score used during assessment. Click here for additional data file.
Table 1

Mean values (± SD) for measured subjective perception scores (average of all readings) including by clinical role. FH1 denotes half mask while FH2 denotes full mask. Surg denotes surgeons and anaes denotes Anaesthesiologists. P values indicate statistical differences between combined means between masks (Mann–Whitney U test) and between clinical roles (Kruskal‐Wallis test)

Assessment 1Assessment 2Assessment 3
Measured scoreMaskLaparoscopic technical skills (n = 14, 90 mins, FH1 & FH2)Laparotomy (n = 4, 120 mins, FH2 only)Theatre simulation (n = 25, FH1 & FH2)
Mean ± SD P Mean ± SDMean ± SD P valueCohortMean ± SD P
Thermal sensationFH10·46 ± 0·59‐1·07 ± 1·14Surg0·00 ± 0·82
‐3 (hot) to +3 (cold)FH2‐0·50 ± 1·10 *0·0020·13 ± 0·45‐0·64 ± 0·930·329Anaes‐1·00 ± 0·93 *0·003 a
Nurses‐1·60 ± 0·70
4‐point thermal comfortFH11·08 ± 0·281·36 ± 0·63Surg1·10 ± 0·32
1 (comfortable) to 4 (very uncomfortable)FH21·67 ± 0·69 *0·0011·00 ± 0·001·14 ± 0·360·511Anaes1·13 ± 0·350·192
Nurses1·50 ± 0·71
Perception of breathingFH11·33 ± 0·481·50 ± 0·76Surg1·00 ± 0·00
1 (not noticeable) to 7 (intolerable)FH21·78 ± 1·060·1601·29 ± 0·461·36 ± 0·500·839Anaes1·88 ± 0·83 *0·012 b
Nurses1·50 ± 0·53
Borg rating of perceived exertionFH16·90 ± 1·237·75 ± 1·67Surg7·60 ± 2·46
6 (no exertion at all) to 20 (maximal exertion)FH28·11 ± 2·30 *0·0476·25 ± 0·578·11 ± 2·290·839Anaes8·50 ± 1·770·444
Nurses7·80 ± 1·67
Eye drynessFH1‐0·04 ± 0·20‐0·36 ± 0·63Surg‐0·10 ± 0·32
‐3 (very dry) to +3 (very wet)FH2‐0·33 ± 0·49 *0·0130·00 ± 0·00‐0·57 ± 0·940·701Anaes‐0·75 ± 1·160·162
Nurses‐0·60 ± 0·70
Ease of communicationFH12·46 ± 0·592·00 ± 0·00Surg1·60 ± 0·52
0 (impossible) to 4 (easier than normal)FH22·22 ± 0·730·3041·96 ± 0·361·43 ± 0·51 *0·009Anaes1·88 ± 0·350·449
Nurses1·70 ± 0·48
Listening effortFH13·00 ± 0·782·14 ± 0·86Surg1·80 ± 0·79
0 (nothing understood) to 4 (no effort)FH22·83 ± 0·920·5812·04 ± 0·811·71 ± 0·730·210Anaes2·25 ± 0·890·432
Nurses1·80 ± 0·79

Statistically significant results (P < 0·05). Statistically significant P value (Mann–Whitney U test) for

surgeons versus nurses with respect to thermal sensation score and for

surgeons versus anaesthesiologists for perception of breathing.

  5 in total

1.  Surgical ethics during a pandemic: moving into the unknown?

Authors:  J Ives; R Huxtable
Journal:  Br J Surg       Date:  2020-04-20       Impact factor: 6.939

Review 2.  Safe management of surgical smoke in the age of COVID-19.

Authors:  N G Mowbray; J Ansell; J Horwood; J Cornish; P Rizkallah; A Parker; P Wall; A Spinelli; J Torkington
Journal:  Br J Surg       Date:  2020-05-03       Impact factor: 6.939

Review 3.  Immediate and long-term impact of the COVID-19 pandemic on delivery of surgical services.

Authors:  K Søreide; J Hallet; J B Matthews; A A Schnitzbauer; P D Line; P B S Lai; J Otero; D Callegaro; S G Warner; N N Baxter; C S C Teh; J Ng-Kamstra; J G Meara; L Hagander; L Lorenzon
Journal:  Br J Surg       Date:  2020-04-30       Impact factor: 6.939

4.  Elective surgery after the pandemic: waves beyond the horizon.

Authors:  J Mayol; C Fernández Pérez
Journal:  Br J Surg       Date:  2020-05-08       Impact factor: 6.939

Review 5.  Global guidance for surgical care during the COVID-19 pandemic.

Authors: 
Journal:  Br J Surg       Date:  2020-04-15       Impact factor: 6.939

  5 in total
  3 in total

1.  Personal Protective Equipment in COVID-19: Impacts on Health Performance, Work-Related Injuries, and Measures for Prevention.

Authors:  Xiaoqin Duan; Hongzhi Sun; Yuxuan He; Junling Yang; Xinming Li; Kritika Taparia; Bin Zheng
Journal:  J Occup Environ Med       Date:  2021-03-01       Impact factor: 2.306

2.  Solving the problems of gas leakage at laparoscopy.

Authors:  R A Cahill; J Dalli; M Khan; M Flood; K Nolan
Journal:  Br J Surg       Date:  2020-08-27       Impact factor: 6.939

3.  Gas leaks through laparoscopic energy devices and robotic instrumentation - a video vignette.

Authors:  J Dalli; M F Khan; K Nolan; R A Cahill
Journal:  Colorectal Dis       Date:  2020-08-09       Impact factor: 3.917

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.