Dear Editor, We congratulate Wang and colleagues for their interesting paper concerning the ultrasound evaluation of the optic nerve sheath diameter (ONSD) in a young patient with an aneurysmal subarachnoid hemorrhage and spinal arachnoiditis. We would like to comment this article because, in our opinion, some points need to be clarified. In the “Introduction” section, the authors stated that the possibility to assess the increase in intracranial pressure (ICP), measuring ONSD, was discovered in 1989. This statement is incorrect because other papers described this possibility before the one the authors cited. , The lack of a standard setting makes B‐scan measurements subjective and quite unreliable in case of small structures such as ONSD. In other words, a lower gain setting will show larger measurements compared to the ones got with a higher gain setting (blooming effect). , , , , We are aware that in a previous paper the authors found a good correlation between ONSD and ICP changes, but unfortunately the formula they found, due to the blooming effect, makes it difficult to utilize in other hospitals. To overcome this main limitation, we would like to suggest the use of the Standardized A‐Scan technique, which is blooming effect free and displays easily noticeable hyperreflective spikes from the interface between arachnoid and subarachnoidal fluid, providing exacter measurements. , , The authors correctly stated that papilledema and hemorrhages could not only indicate increased ICP but also optic nerve inflammation or optic nerve compartment syndrome. Standardized A‐scan is a very useful tool to resolve this doubt. In fact, it permits to perform the “30 degrees test,” which allows us to distinguish between an ONSD increase caused by raised ICP related to increased subarachnoidal fluid, and that one associated with other diseases. , , In addition, it is also possible to perform the “optic nerve exercise” to exclude an optic nerve compartment syndrome. This test is performed by inviting the patient to look alternatively to the extremely right and left lateral sides for 15–20 s. The test will lasts 3 min, afterwards, the patient is given 2 min too rest with closed eyes allowing the subarachnoidal fluid, which was shifted from the orbit during the exercise, to return into the orbit. In the healthy people, the original amount of orbital subarachnoidal fluid will be normally restored while, in case of an optic nerve compartment syndrome, this will not happen.

Conflict of Interest

The authors declare they have no conflict of interest.
  12 in total

1.  Optic nerve sheath diameter measurement in hypoxic ischaemic brain injury after cardiac arrest.

Authors:  Nicola Rosa; Livio Vitiello; Maddalena De Bernardo
Journal:  Resuscitation       Date:  2019-03-13       Impact factor: 5.262

2.  Optic nerve ultrasound measurement in multiple sclerosis.

Authors:  Maddalena De Bernardo; Livio Vitiello; Nicola Rosa
Journal:  Acta Neurol Scand       Date:  2019-02-18       Impact factor: 3.209

Review 3.  Pediatric liver diseases and ocular changes: What hepatologists and ophthalmologists should know and share with each other.

Authors:  Livio Vitiello; Maddalena De Bernardo; Salvatore Guercio Nuzio; Claudia Mandato; Nicola Rosa; Pietro Vajro
Journal:  Dig Liver Dis       Date:  2019-12-13       Impact factor: 4.088

4.  Transbulbar B-Mode Sonography in Multiple Sclerosis: Clinical and Biological Relevance.

Authors:  Maddalena De Bernardo; Nicola Rosa
Journal:  Ultrasound Med Biol       Date:  2017-11-15       Impact factor: 2.998

5.  Optic nerve sheath diameter measurement in patients with idiopathic normal-pressure hydrocephalus.

Authors:  M De Bernardo; N Rosa
Journal:  Eur J Neurol       Date:  2018-02       Impact factor: 6.089

6.  Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and its Application to Detect Intracranial Hypertension in Children.

Authors:  Maddalena De Bernardo; Livio Vitiello; Nicola Rosa
Journal:  Am J Ophthalmol       Date:  2019-10-11       Impact factor: 5.258

7.  A-scan ultrasonography and optic nerve sheath diameter evaluation in children with acute liver failure.

Authors:  Maddalena De Bernardo; Livio Vitiello; Michela Capone; Nicola Rosa
Journal:  Liver Int       Date:  2020-01-12       Impact factor: 5.828

8.  Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter.

Authors:  Li-Juan Wang; Yan Yao; Liang-Shu Feng; Yu-Zhi Wang; Nan-Nan Zheng; Jia-Chun Feng; Ying-Qi Xing
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

9.  Comments on "Neuromuscular Ultrasonography of Cranial Nerves".

Authors:  Maurizio Tenuta; Maddalena De Bernardo; Nicola Rosa
Journal:  J Clin Neurol       Date:  2017-04       Impact factor: 3.077

10.  Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection.

Authors:  Li-Juan Wang; Hong-Xiu Chen; Ying Chen; Ze-Yang Yu; Ying-Qi Xing
Journal:  Ann Clin Transl Neurol       Date:  2020-05-07       Impact factor: 4.511

View more
  5 in total

1.  Optic Nerve Drusen Evaluation: A Comparison between Ultrasound and OCT.

Authors:  Nicola Rosa; Maddalena De Bernardo; Giulia Abbinante; Gianluca Vecchio; Ferdinando Cione; Luigi Capasso
Journal:  J Clin Med       Date:  2022-06-27       Impact factor: 4.964

Review 2.  Optic Nerve Ultrasound Evaluation in Idiopathic Intracranial Hypertension.

Authors:  Maddalena De Bernardo; Livio Vitiello; Ilaria De Pascale; Luigi Capasso; Palmiro Cornetta; Nicola Rosa
Journal:  Front Med (Lausanne)       Date:  2022-03-01

3.  Reply to: Ocular ultrasonography to detect intracranial pressure in aneurysmal subarachnoid hemorrhage.

Authors:  Hong-Xiu Chen; Li-Juan Wang; Ying-Qi Xing
Journal:  Ann Clin Transl Neurol       Date:  2020-07-13       Impact factor: 4.511

Review 4.  Optic Nerve Ultrasound Evaluation in Animals and Normal Subjects.

Authors:  Livio Vitiello; Maddalena De Bernardo; Luigi Capasso; Palmiro Cornetta; Nicola Rosa
Journal:  Front Med (Lausanne)       Date:  2022-01-05

5.  Comparing ultrasonographic optic nerve sheath diameter to head computed tomography scan to predict intracranial pressure elevation.

Authors:  Shierly Novitawati Sitanaya; Fadhila Kamayanti; Hari Adityo Nugroho; Bobi Prabowo
Journal:  SAGE Open Med       Date:  2022-02-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.