Fang Wan1,2, Tianwu Chen1,2, Yunshen Ge1,2, Peng Zhang1,2, Shiyi Chen1,1. 1. Department of Orthopedic Sports Medicine, Huashan Hospital, Shanghai, China. 2. Fudan University Sports Medicine Institute, Shanghai, China.
Abstract
BACKGROUND: In anterior cruciate ligament (ACL) reconstruction, minimizing the graft-tunnel motion (GTM) will promote graft-to-bone healing and avoid graft loosening or tearing as well as potential bone tunnel enlargement. A nearly isometric state of the graft can be achieved by placing the tunnel properly to theoretically gain better graft-to-bone healing. However, little clinical evidence is available to quantify the relation between GTM and tunnel position. PURPOSE: To find the proper zones for the femoral and tibial tunnel apertures that minimize the GTM, referred to as the "nearly isometric zone," through use of intraoperative GTM measurement and 3-dimensional computed tomography (3D-CT). STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: A total of 100 patients were enrolled in this study. Nearly isometric ACL reconstruction was performed, and an intra-articular GTM measuring device was designed to measure and record the amplitude of GTM while the knee was flexed from 0° to 120°. Postoperatively, the patients underwent multislice CT, and the images were used to create 3D-CT models. After tibial aperture examination, 5 patients were excluded due to the divergence of tibial aperture, and therefore 95 patients remained in the study. Patients were divided into 2 groups according to whether the lateral intercondylar ridge was absent or present. The Bernard-Hertel grid coordinates (h, t) of the femoral tunnel were then quantified. RESULTS: The maximal GTM (mGTM) was a mean ± SD of 1.06 ± 0.66 mm (range, 0.0-3.0 mm). The mGTM in patients with a lateral intercondylar ridge was significantly lower than that in patients without a lateral intercondylar ridge (0.81 ± 0.39 vs 1.59 ± 0.73 mm, respectively; P < .0001). The average h and t were 0.227 ± 0.079 and 0.429 ± 0.770, respectively. Notably, in 1 patient, the mGTM was 0 mm whereas the coordinates (h, t) of the femoral tunnel were 0.250 and 0.255. The overall GTM slowly increased before 90° but increased significantly after the knee was bent 105° (P = .010). Correlation analysis showed that the t coordiinate had significant correlation with mGTM (R = 0.581; P < .001). A gradient pattern was created to show the nearly isometric blue zone (mGTM <0.5 mm), which was found to overlap with the IDEAL (isometric, direct insertion, eccentric, anatomic, low tension-flexion pattern) position. CONCLUSION: A method of measuring intraoperative GTM and quantifying femoral tunnel position on postoperative 3D-CT was successfully developed. The presence of a lateral condylar ridge can significantly reduce mGTM. A nearly isometric zone was described that was consistent with the IDEAL concept.
BACKGROUND: In anterior cruciate ligament (ACL) reconstruction, minimizing the graft-tunnel motion (GTM) will promote graft-to-bone healing and avoid graft loosening or tearing as well as potential bone tunnel enlargement. A nearly isometric state of the graft can be achieved by placing the tunnel properly to theoretically gain better graft-to-bone healing. However, little clinical evidence is available to quantify the relation between GTM and tunnel position. PURPOSE: To find the proper zones for the femoral and tibial tunnel apertures that minimize the GTM, referred to as the "nearly isometric zone," through use of intraoperative GTM measurement and 3-dimensional computed tomography (3D-CT). STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: A total of 100 patients were enrolled in this study. Nearly isometric ACL reconstruction was performed, and an intra-articular GTM measuring device was designed to measure and record the amplitude of GTM while the knee was flexed from 0° to 120°. Postoperatively, the patients underwent multislice CT, and the images were used to create 3D-CT models. After tibial aperture examination, 5 patients were excluded due to the divergence of tibial aperture, and therefore 95 patients remained in the study. Patients were divided into 2 groups according to whether the lateral intercondylar ridge was absent or present. The Bernard-Hertel grid coordinates (h, t) of the femoral tunnel were then quantified. RESULTS: The maximal GTM (mGTM) was a mean ± SD of 1.06 ± 0.66 mm (range, 0.0-3.0 mm). The mGTM in patients with a lateral intercondylar ridge was significantly lower than that in patients without a lateral intercondylar ridge (0.81 ± 0.39 vs 1.59 ± 0.73 mm, respectively; P < .0001). The average h and t were 0.227 ± 0.079 and 0.429 ± 0.770, respectively. Notably, in 1 patient, the mGTM was 0 mm whereas the coordinates (h, t) of the femoral tunnel were 0.250 and 0.255. The overall GTM slowly increased before 90° but increased significantly after the knee was bent 105° (P = .010). Correlation analysis showed that the t coordiinate had significant correlation with mGTM (R = 0.581; P < .001). A gradient pattern was created to show the nearly isometric blue zone (mGTM <0.5 mm), which was found to overlap with the IDEAL (isometric, direct insertion, eccentric, anatomic, low tension-flexion pattern) position. CONCLUSION: A method of measuring intraoperative GTM and quantifying femoral tunnel position on postoperative 3D-CT was successfully developed. The presence of a lateral condylar ridge can significantly reduce mGTM. A nearly isometric zone was described that was consistent with the IDEAL concept.
During the past 20 years, anterior cruciate ligament (ACL) reconstruction has undergone
enormous development in aspects such as bone tunnel positioning, graft choice, and
return to sports.[15] Bone tunnel positioning is one of the most crucial technical factors affecting
outcomes. Inappropriate locations of the bone tunnel will leave the graft in a
nonisometric state[24] that may result in abnormal tensile and relative movement between the graft and
the tunnel during knee flexion (see Supplementary Video). This kind of motion between
graft and tunnel is called graft-tunnel motion (GTM).[10] The phenomenon leading to GTM was described in the late 1990s.[11] Some scholars believe that GTM can affect the graft-to-bone interface[10,11]; that is, GTM will impair graft and bone tunnel healing by changing the local
mechanical environment. Others consider that GTM is the expression of a “windshield
wiper effect” and “bungee effect” that will increase bone absorption activity around the
bone tunnel, resulting in bone tunnel enlargement.[18] In our clinical practice, we find that nonisometric reconstruction overstressing
the graft may limit the range of motion and result in graft failure, cartilage damage,
and osteoarthritis. We have directed our attention to the kinematic and mechanical
influence of nonisometric reconstruction of the knee since we began to use artificial
ligament grafts more than 10 years ago.[4]Rodeo et al[18] used animal experiments to prove the existence of GTM, reporting that the
amplitude of GTM had a positive correlation with the width of graft-bone interface and a
negative correlation with the healing progress. Nakase et al,[16] using magnetic resonance imaging (MRI) for follow-up of patients who received ACL
reconstruction, found differences in healing for different portions of the graft not
only longitudinally but also transversally. These investigators suggested that the
windshield wiper effect caused anterior-posterior GTM that impaired the healing
process.Pearle et al[17] suggested a femoral tunnel position that they called IDEAL (isometric, direct
insertion, eccentric, anatomic, low tension-flexion pattern). Such a position reproduces
the isometry of the native ACL, covers the fibers of the direct insertion
histologically, is eccentrically located in the anterior (high) and proximal (deep)
region of the footprint, is anatomic (within the footprint), and replicates the low
tension-flexion pattern of the native ACL throughout the range of flexion and
extension.Most of the previous studies have been performed on animals and cadavers; the question
remained how GTM could be observed clinically. In a small sample clinical study,
investigators proved the existence of GTM in vivo by marking the intra-articular portion
of the graft with a titanium suture.[2] After the surgery, GTM could be directly observed and measured under fluoroscopy.
Despite the effectiveness of this technique, it is not suitable for large-scale
application because of ethical issues. Until now, no technique has been available that
can be used clinically to observe GTM directly in vivo or postoperatively.Theoretically, an absolutely isometric ACL reconstruction can minimize GTM. However,
native ACL has been considered “nonisometric” from a biomechanical perspective. The
concept of clinical isometry refers to tunnel placement such that the
distance between the femoral and tibial tunnel apertures remains constant as the knee
moves in the plane of flexion and extension.[1] However, surgeons have found that it is almost impossible to achieve absolute
isometry during surgery.[6,9,20] Nonetheless, nearly isometric reconstruction can be achieved occasionally by
holding GTM to a minimum, about 1.0 to 2.0 mm.Thus, we use the term near isometry to describe the condition mentioned
above that can be confirmed by direct measurement of the GTM during knee flexion
intraoperatively. We hypothesized that (1) GTM correlates with femoral tunnel position,
and (2) not only a point but also a zone exists for an ACL graft to be reconstructed at
a nearly isometric state throughout the range of motion. Once the tunnel is positioned
at this specific, nearly isometric zone, the GTM will be minimized. To prove our
hypotheses, we conducted a prospective clinical study. In this study, we performed the
nearly isometric ACL reconstruction on a series of patients with ACL deficiency. Using a
custom-made measurement tool, we were able to measure GTM intraoperatively.
Postoperative 3-dimensional computed tomography (3D-CT) was applied to quantify the
coordinates of tunnel apertures in order to study the correlation between apertures and
GTM. We sought to investigate the nearly isometric zone of the femoral tunnel aperture
and confirm its effect on minimize GTM. We found that we can place the tunnels optimally
by using GTM as a reference.
Methods
Patient Selection
Institutional review board approval was obtained before the study began. The
study included all patients who received ACL reconstruction from September 2014
to March 2018 in our center. The inclusion criteria were (1) age 20 to 50 years
and (2) sole initial ACL tear or rupture. The exclusion criteria were (1)
fracture, (2) revision, (3) concomitant knee injuries such as posterior cruciate
ligament and meniscal injury, (4) medical conditions such as metabolic and
rheumatoid diseases, (5) osteoarthritis, and (6) tibial aperture beyond 42% to
50% anterior-posterior of the plateau (described later). All patients provided
informed consent, and their demographic data were collected.
ACL Reconstruction
The same senior chief surgeon (S.C.) performed all surgeries. The type of the
graft was chosen based on the agreement between surgeon and patients. The
selection consisted of quadruple hamstring autograft, allograft, or synthetic
graft. When hamstring autograft and allograft were used, the femoral side was
fixed with suspensory ACL TightRope (Arthrex) and the tibial side was fixed with
bioabsorbable interference screw with sheath (BioIntrafix; Mitek). Both femoral
and tibial side were fixed with titanium interference screw when a synthetic
graft was used. The tunnel diameter was 8 mm on autograft and allograft and 7.5
mm on synthetic graft (LARS; Surgical Implants and Devices).In addition to the regular medial and lateral portals for knee arthroscopy, a
midpatellar tendon portal was made to visualize the medial aspect of the lateral
condyle. After the torn ACL was confirmed, debridement of the femoral insertion
was confirmed to expose the intercondylar ridge and bifurcation ridge on the
medial aspect of the lateral condyle. The tibial ACL remnant should be maximally
preserved according to the senior surgeon’s personal technique.
Nearly Isometric Zone Positioning
Femoral Tunnel Position
The direction of the medial femoral condyle is shown in Figure 1A. The
intersection of the lateral intercondylar ridge and bifurcation ridge is
a crucial landmark to localize the aperture of the femoral tunnel. The
nearly isometric femoral tunnel was positioned on the lateral
intercondylar ridge, 2 mm proximal (deep) to the bifurcation ridge. If
the lateral intercondylar ridge was missing, the nearly isometric
femoral tunnel was positioned on the extension of the femoral posterior
cortex line (long red line on Figure 1A), 5 mm distal (shallow)
to the femoral posterior cortex wall (green dotted line on Figure 1A).
Figure 1.
(A) Designated femoral and tibial tunnel position. (Left) On the
medial aspect view of the lateral femoral condyle, the anterior
(high), posterior (low), distal (shallow), and proximal (deep)
directions are shown. The long red line is the femoral posterior
cortex line and the lateral condylar ridge. The short red line
is the bifurcation ridge. The red oval is the designated “nearly
isometric” femoral tunnel. The green dotted line is the femoral
posterior cortex wall. The blue dot is the center of the
designated tunnel. (Right) On the overlook view of the tibial
plateau, the blue arc is the anterior cruciate ligament tibial
remnant (usually C-shaped). The red oval is the designated
tunnel. The blue dot is the center of the designated tunnel. (B)
(Left) Quantification of the tibial tunnel position with
coordinates (a, b). Two tangent vertical lines
are drawn along medial and lateral edges of the tibial plateau.
Two additional tangent lines are drawn along the anterior and
posterior edges at right angles to the previous 2 lines. The
anteroposterior position of the tunnel is defined relative to a
rectangular grid with origin (0,0) at the anteromedial corner of
the rectangle. The anteroposterior position is determined by the
ratio a:A, and the mediolateral position is
given as the ratio b:B. This yields coordinates
(a, b), where both a and
b have values between 0 and 1, to define
the location of the tunnel relative to the tibial surface.
(Right) A Bernard-Hertel grid is used to calculate the
coordinates (h, t) to quantify the femoral
tunnel position.
(A) Designated femoral and tibial tunnel position. (Left) On the
medial aspect view of the lateral femoral condyle, the anterior
(high), posterior (low), distal (shallow), and proximal (deep)
directions are shown. The long red line is the femoral posterior
cortex line and the lateral condylar ridge. The short red line
is the bifurcation ridge. The red oval is the designated “nearly
isometric” femoral tunnel. The green dotted line is the femoral
posterior cortex wall. The blue dot is the center of the
designated tunnel. (Right) On the overlook view of the tibial
plateau, the blue arc is the anterior cruciate ligament tibial
remnant (usually C-shaped). The red oval is the designated
tunnel. The blue dot is the center of the designated tunnel. (B)
(Left) Quantification of the tibial tunnel position with
coordinates (a, b). Two tangent vertical lines
are drawn along medial and lateral edges of the tibial plateau.
Two additional tangent lines are drawn along the anterior and
posterior edges at right angles to the previous 2 lines. The
anteroposterior position of the tunnel is defined relative to a
rectangular grid with origin (0,0) at the anteromedial corner of
the rectangle. The anteroposterior position is determined by the
ratio a:A, and the mediolateral position is
given as the ratio b:B. This yields coordinates
(a, b), where both a and
b have values between 0 and 1, to define
the location of the tunnel relative to the tibial surface.
(Right) A Bernard-Hertel grid is used to calculate the
coordinates (h, t) to quantify the femoral
tunnel position.
Tibial Tunnel Position
Unlike the situation with the femoral ACL footprint, a major residual of
the ACL is often visible on the tibial ACL footprint medial to the
anterior horn of the lateral meniscus. It is often difficult to identify
the bare tibial footprint without debriding the remnant. Whether the
remnant should be preserved remains controversial. Our preference is to
preserve the remnant as much as possible in order to promote healing,
which is also crucial for the synthetic graft because it is designed for
augmentation. We prefer to split the remnant into halves from the middle
line and point the tip of a 55° tibial ACL aimer (pointing toward the
elbow) 3 to 4 mm posterior to the middle point of the remnant (Figure 1A).
GTM Measurement
According to the length of the femoral tunnel, the intra-articular portion of the
graft was marked with 3 absorbable suture knots on the femoral and tibial
apertures and middle site, 1 cm away from each other. After the graft was placed
in the tunnel, femoral fixation was completed. Then, the knee was flexed 20
times passively with 200 N of tension with a graft tensioning device applied on
the tibial side. Keeping the tension on the tibial side, we placed a custom-made
intra-articular GTM measuring device (0.2-mm precision; patent No. CN105078467B)
into the joint. We adjusted the angle of the device so that the tip was anchored
on the tibial aperture and so the device and graft were parallel with each other
(Figure 2). The
maximal amplitude of GTM (mGTM) was measured, and a video recording was made
while the knee was flexed from 0° to 120°. The GTM data were recorded at 0°,
15°, 30°, 60°, 90°, 105°, and 120°.
Figure 2.
A custom-made intra-articular graft-tunnel motion (GTM) measuring device
is used to measure GTM arthroscopically according to pre-embedded
sutures (red arrow) on the graft. An enlarged detail of the tip of the
device (red circle) shows that each black block is 0.2 mm in width, as
validated by a digital Vernier caliper (Appendix
Figure A1).
A custom-made intra-articular graft-tunnel motion (GTM) measuring device
is used to measure GTM arthroscopically according to pre-embedded
sutures (red arrow) on the graft. An enlarged detail of the tip of the
device (red circle) shows that each black block is 0.2 mm in width, as
validated by a digital Vernier caliper (Appendix
Figure A1).
Figure A1.
On the tip of our custom-designed graft-tunnel motion measurement device,
each black block is 0.2 mm in width, as validated by a digital Vernier
caliper (Masterproof).
Multislice CT and 3D Reconstruction
All of the patients underwent multislice CT scanning (Toshiba Aquilion Prime) on
the surgical knee 1 day postoperatively. The scan used the default factory
preset (voltage, 140 kV; baseline, B40S) of knee CT with 0.5 mm thickness per
slice in 5 seconds. All of the raw data were processed and reconstructed by use
of a Vitrea imaging workstation (Vital Images Inc). The 3D volume-rendering
model of the knee was split into a femoral part and a tibial part, which were
analyzed separately (Figure
1B) in the following 2 steps. First, the distribution of the aperture
of the tibial tunnel was confirmed by comparing the overlook view of tibial
plateau. A rectangular coordinate system was used to quantify the coordinates
(a, b) of the tibial tunnel. The tibial aperture was
required to be in a position 42% to 50% anterior-posterior of the plateau (0.42
≤ a ≤ 0.56), which was considered a “constant,” in order that
the femoral aperture was a single variant. Otherwise, the case was excluded.
Through tibial aperture examination, 5 patients were excluded due to the
divergence of tibial aperture (a > 0.58 or
a < 0.5). The a and b
(mean ± SD) for the excluded patients were 0.461 ± 0.075 and 0.491 ± 0.062,
respectively.Second, a sagittal cut was made on the femoral part along the top point of the
intercondylar notch parallel to the femoral axis to expose the aperture of
femoral tunnel. Then, the aperture point was coordinated by use of a
Bernard-Hertel grid,[6] with the coordinates (h, t) of each case recorded. The
presence or absence of the lateral intercondylar ridge was recorded.
Statistical Analysis
The patients were divided into groups according to sex, graft type, and the
presence or absence of a lateral intercondylar ridge. Statistical analysis
included 1-way analyses of variance (ANOVAs) for comparison of GTM results from
different groups. The Pearson correlation coefficient was used to calculate the
correlation between the h coordinate of the femoral aperture
and the mGTM and between the t coordinate and the mGTM,
respectively. All statistical analysis was performed with MedCalc Statistical
Software version 18.2.1 (MedCalc Software bvba). The significance level was set
at P < .05.
Results
For our clinical study, we enrolled 100 patients who had nearly isometric ACL
reconstruction. After tibial aperture exclusion, 95 patients were involved.
Demographic information is listed in Table 1.
Table 1
Demographic Information of Study Participants
Parameter
Result
Sex, male:female, n
78:17
Age, y, mean ± SD
27.08 ± 8.39
Left side affected, n
45
Interval from injury to surgery, wk, median (range)
78.1 (2.1-521.5)
Graft type, n
Allograft
21
Autograft
50
Synthetic
24
Graft size, n
7.5 mm
24
8 mm
71
Maximal graft-tunnel motion, mm, mean ± SD (range)
1.06 ± 0.66 (0-3)
Lateral intercondylar ridge, n
Absent
20
Present
75
Demographic Information of Study ParticipantsThe mGTM (mean ± SD) was 1.06 ± 0.66 mm (range, 0-3.0 mm). No significant differences
were found between mGTM and sex (P = .233), side
(P = .572), or graft type (P = .526). The
lateral intercondylar ridge was present in 78.9% of the patients and absent in
21.1%. Interestingly, the mGTM in the group who had a lateral intercondylar ridge
was significantly lower than that in the group without a lateral intercondylar ridge
(0.81 ± 0.39 vs 1.59 ± 0.73 mm; P < .0001) (Figure 3).
Figure 3.
Maximal graft-tunnel motion (mGTM) was significantly lower in patients with a
lateral intercondylar ridge. *P < .0001.
Maximal graft-tunnel motion (mGTM) was significantly lower in patients with a
lateral intercondylar ridge. *P < .0001.The mean h and t in the total sample were 0.227 ±
0.079 and 0.429 ± 0.770, respectively. The mean h and
t were 0.218 ± 0.074 and 0.408 ± 0.064 in patients who had a
lateral intercondylar ridge compared with 0.123 ± 0.085 and 0.458 ± 0.084 in
patients without a lateral intercondylar ridge. Notably, in 1 patient, the mGTM was
0 mm while the coordinates (h, t) of the femoral tunnel were
(0.250, 0.255). The femoral tunnel was approximately on the lateral intercondylar
ridge and 2 mm proximal (deep) to the bifurcation ridge.We further classified the patients according to their mGTM, or isometric level, as:
(1) blue, 0 mm ≤ mGTM ≤ 0.5 mm (n = 22); (2) green, 0.5 mm < mGTM ≤ 1 mm (n =
39); (3) yellow, 1 mm < mGTM ≤ 2 mm (n = 28); (4) red, 2 mm < mGTM ≤ 3 mm (n =
6). The tendency for GTM with different knee angles was also analyzed. We discovered
that the overall GTM was slight and increased slowly before 90° but increased
significantly after the knee was bent at 105° (P = .010) (Figure 4A).
Figure 4.
(A) Patients were divided into 4 groups according to their maximal
graft-tunnel motion (mGTM): (1) blue, 0 mm ≤ mGTM ≤ 0.5 mm (n = 22); (2)
green, 0.5 mm < mGTM ≤ 1 mm (n = 39); (3) yellow, 1 mm < mGTM ≤ 2 mm
(n = 28); (4) red, 2 mm < mGTM ≤ 3 mm (n = 6). The overall GTM increased
significantly after the knee was bent at 105° (P = .010).
(B) All of the femoral aperture coordinates were projected onto the same
medial aspect of the lateral condyle according to their group color. (C) A
gradient pattern was made to show the nearly isometric zone. The blue zone
was found to overlap with IDEAL position described by Pearle et al[17] (black circle).
(A) Patients were divided into 4 groups according to their maximal
graft-tunnel motion (mGTM): (1) blue, 0 mm ≤ mGTM ≤ 0.5 mm (n = 22); (2)
green, 0.5 mm < mGTM ≤ 1 mm (n = 39); (3) yellow, 1 mm < mGTM ≤ 2 mm
(n = 28); (4) red, 2 mm < mGTM ≤ 3 mm (n = 6). The overall GTM increased
significantly after the knee was bent at 105° (P = .010).
(B) All of the femoral aperture coordinates were projected onto the same
medial aspect of the lateral condyle according to their group color. (C) A
gradient pattern was made to show the nearly isometric zone. The blue zone
was found to overlap with IDEAL position described by Pearle et al[17] (black circle).Through correlation analysis, the t coordinate showed significant
correlation with mGTM (R = 0.581; P < .001).
All of the femoral aperture coordinates were projected onto the same medial aspect
of the lateral condyle according to their color group: blue, green, yellow, or red
(Figure 4B). A gradient
pattern was made on the medial aspect of the lateral condyle to show the nearly
isometric zone (Figure 4C).
The blue zone had minimal GTM, the green zone was nearly isometric, and the yellow
and red zones were nonisometric with more GTM.
Discussion
The GTM in ACL reconstruction merits more attention. It is crucial to achieve nearly
isometric ACL reconstruction to improve outcomes. According to the current study,
whether an ACL reconstruction can be considered nearly isometric can be determined
as follows: Once the femoral graft fixation is completed, tension is applied on the
tibial side and the intra-articular graft is observed with the method described
above. If GTM is less than 2.0 mm while the knee is flexed from 0° to 120°, this is
considered nearly isometric reconstruction. Although GTM may still exist at a
microscopic level, the adverse effect of GTM on the graft-tunnel interface will be
greatly reduced.While reviewing previous articles, we found that the concept of near isometry has
been occasionally used but with varied definitions.[1,5,13,19] Sidles et al[19] defined near isometry as “length change less than 0.4 mm for 0° to 110° knee
flexion.” Rodeo et al[18] referred to the concept as “less than 2.0 mm during 0° to 90° knee flexion.”
Dabirrahmani et al[5] defined it as “±3.0 mm length change during 0° to 90° knee flexion.” Others
thought it acceptable if the distance change was less than 2.0 mm from 0° to 120° of flexion.[9,19,25] In our study, the mean mGTM was 1.06 ± 0.66 mm, and our criterion for near
isometry was that that length should change less than 2.0 mm for 0° to 120° of knee
flexion.Take et al[21] compared the excursion of bone–patellar tendon–bone grafts during
flexion-extension movement between isometric and anatomic reconstruction techniques
in ACL reconstruction. The mean length change of the grafts in total was 1.0 ± 0.7
mm in the isometric technique and 3.4 ± 0.9 mm in the anatomic technique, quite
similar to our results. However, the properties of bone–patellar tendon–bone graft
are quite different from those of soft tissue graft and synthetic graft. Also, the
measuring method was extra-articular and indirect.We believe that there must be an isometric zone located on the medial surface of the
lateral femoral condyle compatible with a certain tibial tunnel aperture. An ideal
nearly isometric reconstruction must meet the following 2 requirements: (1) After
the nearly isometric reconstruction, the mGTM of the graft should be less than 2.0
mm, and (2) there should not be any impingement between the graft and intercondylar
notch and posterior cruciate ligament.Lee et al[12] conducted a more precise human anatomic study to evaluate the isometry of
anatomic femoral tunnel and anterior tibial tunnel positions. They found that the
anatomic femoral tunnel was nonisometric. When a femoral anatomic tunnel is chosen
for ACL reconstruction, the anterior tibial tunnel offers greater isometric benefits
than the conventional tibial tunnel, especially in near full extension.Wang et al[23] found that only 4 of 10 specimens had an isometric point at a variable
anterior point. The end-to-end distances of the anteromedial and posterolateral
bundles were longer in extension and shorter in flexion. Those investigators pointed
out that the nonisometric tendency of the ACL and the end-to-end distance to change
during knee flexion-extension and internal-external rotation should be considered
during ACL reconstruction to avoid overconstraint of the graft. Fu and Jordan[7] confirmed the importance of the lateral intercondylar ridge as a landmark to
guide accurate femoral tunnel placement during ACL reconstruction. In our study, the
femoral tunnels tended to be more posterior and inferior when the lateral
intercondylar ridge was present compared with when it was absent. A clearly
visualized lateral intercondylar ridge is crucial for nearly isometric tunnel
positioning.Theoretically, GTM may differ with different types of graft and fixation devices.
Hoher et al[10] found that hamstring graft motion existed in the femoral bone tunnel when
using titanium button and polyester tape fixation. Tsuda et al[22] reported that EndoButton fixation of a soft tissue graft via an elastic
material resulted in significantly greater GTM and, consequently, greater anterior
knee laxity compared with more rigid fixation using an interference screw closer to
the intra-articular entrance of the bone tunnel. However, the methods of measuring
GTM used in those cadaveric studies were different from the method used in our
study. However, we did not find significant differences in mGTM among the 3 graft
type groups intraoperatively.Hart et al[8] evaluated femoral tunnel positioning by using 3D MRI. Although 3D MRI
provides slightly more information than 3D-CT, 3D MRI is far more time-consuming (45
minutes vs 5 seconds, respectively) and expensive (700 RMB vs 300 RMB in China,
respectively) than 3D-CT. Despite the minor radiation exposure, 3D-CT is
cost-efficient and can be performed routinely.Coincidentally, in our study, the nearly isometric blue zone overlapped with the
“IDEAL position” as described by Pearle et al[17] (black circle on Figure
4C). Thus, our nearly isometric zone was consistent with the IDEAL
position.Finally, we discovered that the overall GTM was slight and increased slowly before
90° but increased significantly after the knee was bent more than 90°. This finding
might be instructive for the postoperative rehabilitation protocol. Although the
literature emphasizes the importance of early recovery of range of motion (0°-120°),[3] we suggest taking GTM or healing possibility into account at the early stage
of postoperative rehabilitation. If the ACL reconstruction is nearly isometric, the
patient may be allowed 120° of flexion at an early stage of recovery. Otherwise, we
believe the patient should be allowed only 90° of flexion.In summary, the femoral isometric tunnel point varies among individuals. Currently,
we can find the absolute isometric tunnel point only during laboratory studies on
specimens. However, the passive motion of specimens is unable to mimic the motion of
a living knee, so the knowledge we gain from the laboratory offers limited
assistance in terms of clinical procedures. Even by using intraoperative fluoroscopy,[14] we still cannot achieve absolute isometry. This led to our concept of nearly
isometric ACL reconstruction.Overall, current knowledge about GTM, including its mechanisms and consequences, is
limited. We believe that GTM contributes to loosening, retearing, and failure of ACL
reconstruction. To increase the benefit of ACL reconstruction and decrease the
failure rate, more sophisticated studies should be performed. We believe the topic
of isometry and graft-tunnel motion should be brought to the forefront.
Limitations
This study confirmed the possibility of achieving a nearly isometric zone through
use of our nearly isometric reconstruction technique. The limitations of the
study are (1) the lack of a control group, (2) lack of long-term follow-up, and
(3) potential confounding variables stemming from different grafts with
different fixation devices. Also, we did not consider the direction of GTM or
whether the graft moved toward the femur or tibia.
Conclusion
This was a pioneering study investigating the correlation of isometric tunnel
position and GTM by using intraoperative measurement and a postoperative 3D-CT
coordinate system. A nearly isometric zone can be achieved by exact tunnel placement
in both the femoral tunnel aperture and the tibial plateau, which will minimize GTM.
A feasible, simple, and radiation-free technique of nearly isometric reconstruction
has been developed that includes direct measurement of GTM intraoperatively. A
clearly visualized lateral intercondylar ridge is crucial for nearly isometric
tunnel positioning. GTM can be minimized in all types of graft in order to gain
better clinical outcomes. Mass spectrometry CT and 3D reconstruction may be used to
evaluate the tunnel position and potential outcomes.A Video Supplement for this article is available at http://journals.sagepub.com/doi/suppl/10.1177/2325967119890382.
Authors: Danè Dabirrahmani; Michael Christopher Hogg; Peter Walker; Daniel Biggs; Ronald Mark Gillies Journal: Comput Biol Med Date: 2013-10-25 Impact factor: 4.589