Literature DB >> 32656101

Cotton-Tipped Plastic Swabs for SARS-CoV-2 RT-qPCR Diagnosis to Prevent Supply Shortages.

Byron Freire-Paspuel1, Patricio Vega-Mariño2, Alberto Velez2, Paulina Castillo2, Eliana Elizabeth Gomez-Santos3, Marilyn Cruz2, Miguel Angel Garcia-Bereguiain1.   

Abstract

CDC and WHO guidelines for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis only recommend synthetic fiber swabs for nasopharyngeal (NP) sampling. We show that cotton-tipped plastic swabs do not inhibit PCR and have equivalent performance to rayon swabs. Cotton-tipped plastic swabs are massively produced worldwide and would prevent swab supply shortages under the current high SARS-CoV-2 testing demands, particularly in developing countries.
Copyright © 2020 Freire-Paspuel, Vega-Mariño, Velez, Castillo, Gomez-Santos, Cruz and Garcia-Bereguiain.

Entities:  

Keywords:  SARS-CoV-2; cotton swab; rayon swab; surveillance; swabs

Mesh:

Substances:

Year:  2020        PMID: 32656101      PMCID: PMC7324669          DOI: 10.3389/fcimb.2020.00356

Source DB:  PubMed          Journal:  Front Cell Infect Microbiol        ISSN: 2235-2988            Impact factor:   5.293


Introduction

NP swab is the reference sampling method for SARS CoV2 diagnosis, as recommended by the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC) (Center for Diseases Control Prevention, 2020; WHO, 2020a,b). The CDC only endorses the use of synthetic fiber-tipped swabs like rayon or nylon swabs on their recent guidelines for SARS-CoV-2 diagnosis (Center for Diseases Control Prevention, 2020). WHO general guidelines for respiratory sample collection recommend either cotton or synthetic fiber swabs (WHO, 2020b), but recent WHO guidelines for SARS-CoV-2 diagnosis only endorse synthetic fiber swabs (WHO, 2020a). Multiple in vitro RT-qPCR diagnosis kits are available on the market for the detection of SARS-CoV-2. Some of them have received emergency use authorization (EUA) from the U.S. Food & Drug Administration (FDA), while others only report validations made by manufacturers. The CDC-designed 2019-nCoV CDC EUA kit (IDT, USA) is based on the SARS-CoV-2-detecting probes N1 and N2, which have received positive evaluation in recent reports (Nalla et al., 2020; Rhoads et al., 2020), and RNase P as an RNA extraction quality control. From the beginning of 2020, the COVID-19 pandemic has spread rapidly from Asia to Europe and the USA but also finally to Africa and Latin America. Public health systems have been challenged and have been overwhelmed in developing countries like Ecuador. In this context, the capacity to perform SARS-CoV-2 tests is limited due to a lack of enough laboratory equipment and trained personnel. Moreover, SARS-CoV-2 diagnosis may be disrupted due to supply shortage. For instance, Ecuador is experiencing a supply shortage of synthetic fiber swabs that is causing diagnosis disruption, particularly in isolated locations like the Galapagos Islands, where we implemented the “LabGal” SARS-CoV-2 diagnosis facility. Under this scenario, we conducted a validation study for NP sampling for SARS-CoV-2 diagnosis using easily available cotton-tipped plastic swabs and did not find the inhibition effect on PCR reaction that occurs with those made of wood.

Methods

Sample Collection

A total of forty-four (44) subjects suspected of SARS-CoV-2 infection during the surveillance implemented since April 7, 2020 in the Galapagos Islands (Ecuador) were included in the study. All of the subjects were tested for SARS-CoV-2 using two different NP sterile plastic swabs: rayon-tipped swabs and cotton-tipped swabs (Puritan Medical Products LLC, USA; see Supplementary Figure 1). Each NP swab was inserted into the nostril until it hit the back of the NP cavity then rotated five times and removed. The test was conducted in both nostrils for each patient, with <2 min of delay between each sample. NP swabs were immersed in a vial containing 0.5 mL TRIS-EDTA (pH 8) and keep refrigerated until arrival at the lab.

Viral RNA Extraction and RT-qPCR for SARS-CoV-2

RNA extraction was performed using the PureLink Viral RNA/DNA Mini Kit (Invitrogen, USA) following the manufacturer's instructions. Also, an extraction control (TRIS-EDTA pH 8) was performed for each set of RNA extractions to exclude cross-contamination. SARS CoV2 was detected using the RT-qPCR CDC protocol. Briefly, two different sets of primers and probes (N1 and N2) are used for SARS-CoV-2 detection, while RNaseP primers and a probe are the housekeeping products for RNA extraction quality control. Following CDC recommendations, the RT-qPCR kit selected was the 2019-nCoV CDC EUA kit (IDT, USA). The assay was validated to detect 1 viral RNA copies/uL by using 2019-nCoV N positive control (IDT, USA) for the N1 and N2 probes. All of the experiments were performed using a CFX96 from BioRad.

Statistics

For statistical analysis of Ct values, the Student's t-test was performed using Excel.

Results

From the 44 subjects included in the study, 33 (33; 75%) individuals were RT-qPCR SARS-CoV-2 positive and 11 (11; 25%) were negative, either with plastic rayon-tipped or plastic cotton-tipped swabs (Table 1). Taking plastic rayon-tipped swab NP sampling as the gold standard, the detection of SARS-CoV-2 by plastic cotton-tipped swab NP sampling yielded a 100% sensitivity and specificity, indicating total agreement among swabs.
Table 1

Performance of plastic cotton-tipped swabs and plastic rayon-tipped swabs for NP sampling for SARS-CoV-2 RT-qPCR diagnosis.

Cotton swab SARS CoV-2 positiveCotton swab SARS CoV-2 negative
Rayon swab SARS CoV-2 positive330
Rayon swab SARS CoV-2 negative011
Performance of plastic cotton-tipped swabs and plastic rayon-tipped swabs for NP sampling for SARS-CoV-2 RT-qPCR diagnosis. Ct (mean ± SD) values for N1, N2, and RNaseP amplicons for plastic rayon-tipped swabs (N1: 33.71 ± 3.93; N2: 36.84 ± 3.17; RNaseP: 33.75 ± 3.05) and plastic cotton-tipped swabs (N1: 32.55 ± 5.14; N2: 34.37 ± 5.25; RNaseP: 27.66 ± 2.95) were not statistically different for viral-specific amplicons N1 and N2 (p = 0.30 and 0.052, respectively) but were statistically significant (p < 0.001) for the RNA extraction quality control housekeeping gene RNaseP, indicating a better RNA extraction yield for plastic cotton-tipped swabs (Table 2).
Table 2

RT-qPCR Ct values for N1, N2, and RNaseP probes for nasopharyngeal samples with cotton and rayon swabs (mean +/– SD).

NSampleN1 CtN2 CtRNaseP Ct
Cotton swabRayon swabCotton swabRayon swabCotton swabRayon swab
1OCOL21,1126,4226,4833,225,130,66
2ELCANANANANA25,3729,3
3MAPINANANANA27,626,09
4CEMI34,1734,27>4039,9428,4729,84
5460NANANANA28,0234,41
6462NANANANA27,3133,91
7465NANANANA29,6433,32
8467NANANANA33,5736,12
9471NANANANA32,9234,24
10474NANANANA29,3636,84
1194330,3432,4133,2336,4625,3231,43
1294431,7537,4134,4>4021,7329,76
1394532,2435,0534,87>4023,1730,8
1494637,5335,839,6240,0025,2730,2
1594738,134,99>40>4023,1131,45
1694927,3134,9529,82>4025,4336,68
1795023,3437,3125,16>4022,6934,6
1895238,5834,6540,0039,7727,7435,53
1995438,1237,19>40>4026,635,73
2095535,3334,637,4740,0026,3733
2196330,4232,6632,3738,0629,2334,64
2296531,6226,733,7632,9227,3235,75
2396625,5332,7628,0237,4926,1127,44
2496726,0531,3427,9436,1526,1232,29
2596823,0227,324,831,9625,0433,02
2697036,0136,2640,00>4024,8736,41
2797730,3730,433,335,3125,2929,14
28978NANANANA25,637,18
2097938,238,44>40>4026,9738,23
30980NANANANA27,7736,45
3198633,932,3137,3437,1226,2636,02
3298737,15>4037,96>4028,8435,53
3398834,7635,5936,839,2732,0834,22
3498935,8136,3637,05>4029,8336,36
3599039,7537,6>40>4031,5535,62
3699128,833,5129,9838,7428,3938,2
3799236,4526,06>4030,0828,5530,46
3899336,139,5840,00>4028,6734,78
3999638,3338,63>40>4028,8636,71
4099728,2733,1129,8238,430,5838,3
4199936,9429,86>4034,0436,3735,83
421.00828,1126,8629,5432,4628,9835,99
431.00930,6431,932,083530,0531,11
441.010NANANANA29,0231,47

NA means “not amplified”.

RT-qPCR Ct values for N1, N2, and RNaseP probes for nasopharyngeal samples with cotton and rayon swabs (mean +/– SD). NA means “not amplified”.

Discussion

We herein report that molecular detection of SARS-CoV-2 using plastic cotton-tipped swab NP sampling is as reliable as using plastic swabs tipped with synthetic fibers like rayon, which are considered to be the gold standard by CDC (Center for Diseases Control Prevention, 2020). The main limitation of the study is the relatively small sample size, which would explain the 100% agreement among swabs. However, we believe that a potential disagreement among swabs in a study with a large sample size would be related to variability associated with the sampling procedure more than with the type of swabs. While our results show that cotton does not inhibit the detection of SARS-COV-2, previous work has shown inhibition by the chemicals in the wood stem of some swabs. This may explain why inexpensive cotton swabs have been excluded from CDC and WHO guidelines for SARS-CoV-2 diagnosis (Center for Diseases Control Prevention, 2020; WHO, 2020a). However, the use of cotton-tipped swabs for respiratory specimen collection is included in the WHO's general guidelines for respiratory specimen collection (WHO, 2020b), and it has been reported to be reliable for respiratory retroviruses like influenza specifically (Moore et al., 2008). Plastic cotton-tipped swabs are cheap and are made worldwide, even in developing countries like Ecuador. Including this type of swab in international guidelines upon more independent validation studies would help to prevent SARS-CoV-2 diagnosis disruption due to swab supply shortage, as recently happened in Ecuador, while keeping high standards for sensitivity and specificity. To our knowledge, this is the second study comparing swabs for SARS-CoV-2 testing (Vermeiren et al., 2020) but the first study suggesting that inexpensive, readily available cotton swabs could serve as a practical alternative to more costly, imported rayon swabs. Additionally, high sensitivity was recently reported for nasal vs. NP sampling for SARS-CoV-2 diagnosis (Péré et al., 2020). Taking together this finding and ours, even sterile short plastic cotton-tipped swabs like the ones used for ear hygiene could represent an alternative under a lack of NP swab supply. We call upon the worldwide microbiology community, particularly at developing countries, to consider those findings and perform more validation studies to endorse plastic cotton swabs for SARS-CoV2 diagnosis to enhance the testing capacity to fight the spread of the current COVID-19 pandemic.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics Statement

All samples have been submitted for routine patient care and diagnostics. Ethical approval for this study was not required since all activities are according to legal provisions defined by the “Comité de Operaciones Especiales Regional de Galápagos” that is leading the Covid19 surveillance in Galapagos Islands. No extra specimens were specifically collected for this validation study. All data used in the current study was anonymized prior to being obtained by the authors.

Author Contributions

MG-B and BF-P wrote the manuscript. All authors contributed to study design, experimental procedures, and revised and approved the final version of the mansucript.

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
  5 in total

1.  Dry cotton or flocked respiratory swabs as a simple collection technique for the molecular detection of respiratory viruses using real-time NASBA.

Authors:  Catherine Moore; Sally Corden; Jaisi Sinha; Rachel Jones
Journal:  J Virol Methods       Date:  2008-09-11       Impact factor: 2.014

2.  Comparison of Abbott ID Now, DiaSorin Simplexa, and CDC FDA Emergency Use Authorization Methods for the Detection of SARS-CoV-2 from Nasopharyngeal and Nasal Swabs from Individuals Diagnosed with COVID-19.

Authors:  Daniel D Rhoads; Sree S Cherian; Katharine Roman; Lisa M Stempak; Christine L Schmotzer; Navid Sadri
Journal:  J Clin Microbiol       Date:  2020-07-23       Impact factor: 5.948

3.  Nasal Swab Sampling for SARS-CoV-2: a Convenient Alternative in Times of Nasopharyngeal Swab Shortage.

Authors:  Hélène Péré; Isabelle Podglajen; Maxime Wack; Edouard Flamarion; Tristan Mirault; Guillaume Goudot; Caroline Hauw-Berlemont; Laetitia Le; Eric Caudron; Sophie Carrabin; Julien Rodary; Tatiana Ribeyre; Laurent Bélec; David Veyer
Journal:  J Clin Microbiol       Date:  2020-05-26       Impact factor: 5.948

4.  Comparison of Copan ESwab and FLOQSwab for COVID-19 Diagnosis: Working around a Supply Shortage.

Authors:  Christie Vermeiren; Xavier Marchand-Senécal; Elena Sheldrake; David Bulir; Marek Smieja; Sylvia Chong; Jessica D Forbes; Kevin Katz
Journal:  J Clin Microbiol       Date:  2020-05-26       Impact factor: 5.948

5.  Comparative Performance of SARS-CoV-2 Detection Assays Using Seven Different Primer-Probe Sets and One Assay Kit.

Authors:  Arun K Nalla; Amanda M Casto; Meei-Li W Huang; Garrett A Perchetti; Reigran Sampoleo; Lasata Shrestha; Yulun Wei; Haiying Zhu; Keith R Jerome; Alexander L Greninger
Journal:  J Clin Microbiol       Date:  2020-05-26       Impact factor: 5.948

  5 in total
  25 in total

1.  Clinical Performance of Three Commercial SARS-CoV-2 Rapid Antigen Tests for Community-Dwelling Individuals in a Tropical Setting.

Authors:  Diana Morales-Jadán; Carolina Viteri-Dávila; Bernardo Castro-Rodriguez; Alexander Paolo Vallejo-Janeta; Ismar A Rivera-Olivero; Franklin Perez; Miguel Angel Garcia-Bereguiain
Journal:  Front Cell Infect Microbiol       Date:  2022-07-05       Impact factor: 6.073

Review 2.  The crucial contribution of the universities on the SARS-CoV-2 surveillance in Ecuador: Lessons for developing countries.

Authors:  Daniela Santander-Gordon; Gabriel A Iturralde; Byron Freire-Paspuel; Marlon S Zambrano-Mila; Diana C Morales; Paolo A Vallejo-Janeta; Barbara Coronel; Heberson Galvis; Tatiana Jaramillo; Christian D Bilvao; Maria B Rodriguez-Paredes; Sebastian Rodriguez-Pazmiño; Juan C Laglaguano; Henry Herrera; Ana Maria Tito; Esteban Ortiz-Prado; Ismar A Rivera-Olivero; Aquiles R Henriquez-Trujillo; Tannya Lozada; Miguel Angel Garcia-Bereguiain
Journal:  One Health       Date:  2021-05-25

3.  3D printing of nasopharyngeal swabs for COVID-19 diagnose: Past and current trends.

Authors:  Aluri Manoj; Monami Bhuyan; Swarup Raj Banik; Mamilla Ravi Sankar
Journal:  Mater Today Proc       Date:  2020-11-25

4.  Analytical and clinical evaluation of a heat shock SARS-CoV-2 detection method without RNA extraction for N and E genes RT-qPCR.

Authors:  Alfredo Bruno; Domenica de Mora; Byron Freire-Paspuel; Angel S Rodriguez; Maria Belen Paredes-Espinosa; Maritza Olmedo; Martha Sanchez; Jennifer Romero; Michelle Paez; Manuel Gonzalez; Alberto Orlando; Miguel Angel Garcia-Bereguiain
Journal:  Int J Infect Dis       Date:  2021-06-21       Impact factor: 3.623

5.  Analytical and Clinical Evaluation of "AccuPower SARS-CoV-2 Multiplex RT-PCR kit (Bioneer, South Korea)" and "Allplex 2019-nCoV Assay (Seegene, South Korea)" for SARS-CoV-2 RT-PCR Diagnosis: Korean CDC EUA as a Quality Control Proxy for Developing Countries.

Authors:  Byron Freire-Paspuel; Miguel Angel Garcia-Bereguiain
Journal:  Front Cell Infect Microbiol       Date:  2021-06-10       Impact factor: 5.293

6.  COVID-19 outbreaks among isolated Amazonian indigenous people, Ecuador.

Authors:  Aquiles R Henriquez-Trujillo; Esteban Ortiz-Prado; Ismar A Rivera-Olivero; Nemonte Nenquimo; Andrés Tapia; Mitchell Anderson; Tannya Lozada; Miguel Angel Garcia-Bereguiain
Journal:  Bull World Health Organ       Date:  2021-07-01       Impact factor: 9.408

7.  Low-Cost Polyester-Tipped Three-Dimensionally Printed Nasopharyngeal Swab for the Detection of Severe Acute Respiratory Syndrome-Related Coronavirus 2 (SARS-CoV-2).

Authors:  Mohammad Alghounaim; Sulaiman Almazeedi; Sarah Al Youha; Jesse Papenburg; Osama Alowaish; Ghadeer AbdulHussain; Rawan Al-Shemali; Ahmad Albuloushi; Saud Alzabin; Khaled Al-Wogayan; Yousef Al-Mutawa; Salman Al-Sabah
Journal:  J Clin Microbiol       Date:  2020-10-21       Impact factor: 5.948

8.  "One health" inspired SARS-CoV-2 surveillance: The Galapagos Islands experience.

Authors:  Byron Freire-Paspuel; Patricio Vega-Mariño; Alberto Velez; Paulina Castillo; Carlos Masaquiza; Ronald Cedeño-Vega; Tannya Lozada; Marilyn Cruz; Miguel Angel Garcia-Bereguiain
Journal:  One Health       Date:  2020-10-20

9.  "Sample pooling of RNA extracts to speed up SARS-CoV-2 diagnosis using CDC FDA EUA RT-qPCR kit".

Authors:  Byron Freire-Paspuel; Patricio Vega-Mariño; Alberto Velez; Marilyn Cruz; Miguel Angel Garcia-Bereguiain
Journal:  Virus Res       Date:  2020-09-24       Impact factor: 3.303

10.  Analytical sensitivity and clinical performance of a triplex RT-qPCR assay using CDC N1, N2, and RP targets for SARS-CoV-2 diagnosis.

Authors:  Byron Freire-Paspuel; Miguel Angel Garcia-Bereguiain
Journal:  Int J Infect Dis       Date:  2020-10-25       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.