Literature DB >> 32654964

Innovative Transthoracic Echocardiographic Imaging on Prone Ventilated Patients With COVID-19 Using a Transesophageal Probe.

Apostolia Marvaki, Alexandros Papachristidis, Eleni Nakou, Eva Toth, Kevin O'Gallagher, Richard Fisher, Ajay M Shah, Mark J Monaghan.   

Abstract

Entities:  

Mesh:

Year:  2020        PMID: 32654964      PMCID: PMC7314442          DOI: 10.1016/j.jcmg.2020.06.005

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


× No keyword cloud information.
Coronavirus disease-2019 (COVID-19) is causing severe pneumonia leading to acute respiratory distress syndrome, a condition where prone ventilation for >12 h/day has proven beneficial (1). Transthoracic echocardiography (TTE) to assess COVID-19-related cardiac complications (2) is very challenging for patients in the prone position. The aim of this study was to examine the feasibility of an innovative use of a transesophageal echocardiography (TEE) probe to perform TTEs in patients with COVID-19 who were invasively ventilated in the prone position. Twenty-one patients were examined. All scans were performed using an Affiniti or CVx system and the X7-2t or X8-2t TEE probes (Philips Healthcare, Andover, Massachusetts). In a small number of patients, several frequencies and harmonics were tested. The low fundamental frequency (“Pen” selection: 2.4 MHz) was found to provide the best image quality as visually assessed by 2 operators. The average duration of a scan with the TEE probe was 16 ± 3 min. In 18 of 21 patients (85.7%), conventional TTEs were performed using the same ultrasound machines and the S5-1 TTE probe (Philips) with the patients in the supine position. For those scans, the operators selected the frequency and harmonic functions based upon their discretion for optimal visualization (HGen: 1.6/3.2 MHz or HPen: 1.3/2.6 MHz). The studies were performed as part of routine clinical assessment or under ethical approval granted by the National Health Service Health Research Authority (REC20/EE/0131). The mean time between the 2 examinations was 3.6 days (range 0 to 12 days) and the order of the scans in each patient was random. In order to acquire transthoracic images with the TEE probe, the operator stood on the left side of the patient at the level of their head, facing the patient’s right side and caudally (Figure 1A ). The probe was slid between the bed mattress and the patient’s chest wall. Ultrasound gel was applied to the transducer surface. The direction of the probe was oblique from the patient’s shoulder toward the mid-sternum. The transducer faced upward and was supported underneath by the operator’s left hand. The probe shaft was held with the right hand to allow rotation, and the machine was operated by another operator. The tip of the probe was placed in the conventional left parasternal position, in the third or fourth left intercostal space. Images of the long axis of the heart were obtained at zero angle as in the conventional TTE parasternal long-axis view (Figure 1B). By increasing the angle to 60-120 degrees, a short axis view of the heart could be obtained, usually at the level of the mitral valve. Rotating the probe clockwise, the mid-papillary level and apical short axis views were obtained (Figure 1B), whereas with counterclockwise rotation, the great arteries were imaged. The application of color Doppler and pulsed and/or continuous wave Doppler allowed assessment of flow (Figure 1C).
Figure 1

Demonstration of the Technique

(A) Demonstration of the technique. (B) (1,2) parasternal long axis (PLAX) and short axis (PSAX) views with the transesophageal echocardiography (TEE) probe. (3,4) PLAX and PSAX views with the transthoracic echocardiography probe. (C) TEE probe scans. (1,2) PLAX and PSAX views with color Doppler. (3) Apical 4-chamber view (4) subcostal short-axis view.

Demonstration of the Technique (A) Demonstration of the technique. (B) (1,2) parasternal long axis (PLAX) and short axis (PSAX) views with the transesophageal echocardiography (TEE) probe. (3,4) PLAX and PSAX views with the transthoracic echocardiography probe. (C) TEE probe scans. (1,2) PLAX and PSAX views with color Doppler. (3) Apical 4-chamber view (4) subcostal short-axis view. The majority of patients were male (81%) and 48% were black. The mean age of the cohort was 55.9 ± 7.7 years, and the mean body mass index was 28.0 ± 4.6 kg/m2. Three patients (14.3%) had a history of coronary artery disease, 5 (23.8%) were diabetic, 3 (14.3%) were smokers, and 4 (19.1%) had a history of lung disease. The TEE and TTE probe echocardiograms were reviewed and interpreted independently by 2 blinded readers, and the image quality was graded as poor, fair, or good, by using criteria previously described (3). From the TEE probe scans, 4 were graded as nondiagnostic (19.0%), 5 were poor (23.8%), 1 was fair (4.8%), and 11 were good (52.4 %). From the 4 echocardiograms performed using the TEE probe, which were nondiagnostic, 2 correlated to poor conventional TTE image quality (both on female patients), and in the other 2, the conventional TTE was also nondiagnostic (both on male patients). The poor quality TEE probe scans corresponded to 3 poor and 1 good quality TTE probe scans (in 1 patient, a TTE probe scan was not available). The fair quality TEE probe scan corresponded to a fair quality TTE scan, and the 11 good quality TEE probe scans correlated to 1 fair and 8 good quality TTE probe scans (in 2 patients, TTE probe scans were not available). In 4 patients a D-shaped left ventricle and dilated right ventricle, compatible with right ventricular pressure overload, was found. In 1 patient, the left ventricular systolic function was found to be mildly impaired, and a small pericardial and pleural effusion were diagnosed in 2 patients. No valvular abnormalities were identified. The agreement between modalities in echocardiographic findings was 100%. The technique described here has not been reported previously and, in 81% of patients, provided adequate image quality for basic left and right ventricular assessment, valve function, and pericardial effusion. In 12 patients, it was possible to acquire apical views and in 4 a subcostal view was feasible (Figure 1C). The unconventional and innovative use of a TEE probe to perform transthoracic echocardiography with the patient in prone positioned and invasively ventilated intensive care unit patients, is feasible and can be of diagnostic quality in most cases. The technique described here can be an alternative or even a superior to conventional TTE in prone patients.
  3 in total

1.  Standardized Delineation of Endocardial Boundaries in Three-Dimensional Left Ventricular Echocardiograms.

Authors:  Alexandros Papachristidis; Elena Galli; Marcel L Geleijnse; Brecht Heyde; Martino Alessandrini; Daniel Barbosa; Michael Papitsas; Gianpiero Pagnano; Konstantinos C Theodoropoulos; Spyridon Zidros; Erwan Donal; Mark J Monaghan; Olivier Bernard; Jan D'hooge; Johan G Bosch
Journal:  J Am Soc Echocardiogr       Date:  2017-09-01       Impact factor: 5.251

2.  Echocardiography during Prone-Position Mechanical Ventilation in Patients with COVID-19: A Proposal for a New Approach.

Authors:  Enrico Giustiniano; Eleonora Padua; Katerina Negri; Renato Maria Bragato; Maurizio Cecconi
Journal:  J Am Soc Echocardiogr       Date:  2020-04-30       Impact factor: 5.251

Review 3.  COVID-19 acute respiratory distress syndrome (ARDS): clinical features and differences from typical pre-COVID-19 ARDS.

Authors:  Peter G Gibson; Ling Qin; Ser Hon Puah
Journal:  Med J Aust       Date:  2020-06-22       Impact factor: 12.776

  3 in total
  2 in total

Review 1.  Echocardiography in Prone Positioned Critically Ill Patients: A Wealth of Information from a Single View.

Authors:  Enrico Giustiniano; Sergio Palma; Massimo Meco; Umberto Ripani; Fulvio Nisi
Journal:  Diagnostics (Basel)       Date:  2022-06-14

2.  Cardiac Involvement in the COVID-19 Pandemic: Hazy Lessons From Cardiac Imaging?

Authors:  Partho P Sengupta; Y S Chandrashekhar
Journal:  JACC Cardiovasc Imaging       Date:  2020-10-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.