| Literature DB >> 32653757 |
Matej Serdinšek1, Tatjana Stopar Pintarič2, Peter Poredoš1, Maruša Selič Serdinšek3, Nejc Umek4.
Abstract
Entities:
Mesh:
Year: 2020 PMID: 32653757 PMCID: PMC7340064 DOI: 10.1016/j.jclinane.2020.109979
Source DB: PubMed Journal: J Clin Anesth ISSN: 0952-8180 Impact factor: 9.452
Fig. 1Time to airway device placement (A) using direct laryngoscopy (DL), Airtraq, C-MAC and I-Gel with () and without (■) protective box (n = 36). Values are median, inter-quartile-range and range. *p < 0.05 vs. airway device placement time without the protective box (Wilcoxon signed-rank test). Inside view (B) of the protective box. Lateral view (C) of the protective box. Simulation of droplet contamination of the gloves (D) with red colour. Access hole closure was contaminated (painted) only on the inner side (E), while it stayed uncontaminated (F) on the outer side when the contaminated hand was pulled out of the box. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)