PURPOSE: To report intraoperative performance and long-term postoperative outcomes after scleral fixation of intraocular lenses (IOLs) with polytetrafluoroethylene suture (PTFE). SETTING: Raghudeep Eye Hospital, Ahmedabad, India. DESIGN: Prospective, interventional case series. METHODS: One hundred eyes undergoing scleral fixation of IOLs using PTFE suture (Gore-Tex) with 12 months or more postoperative follow-up were included. The primary outcome measures were occurrence of intraoperative and postoperative complications such as glaucoma, suture-related complications, and inflammation within the follow-up period. The secondary outcome measure was improvement in visual acuity (VA). RESULTS: Of the 100 eyes, posteriorly dislocated IOLs (53 eyes) followed by dropped nuclei (33 eyes) were the most common surgical indications. Mean follow-up was 23 months (range 12 months to 5 years). Seventy-one patients (77.17%) had 18 months or more follow-up; 21 eyes had a rise in intraocular pressure in the early postoperative period; 12 of them required glaucoma surgery. Early complications were vitreous hemorrhage in 13 eyes, retinal detachment in 6 eyes, and transient hyphema in 1 eye. Late postoperative complications were cystoid macular edema (9 eyes), epiretinal membrane (3 eyes), and bullous keratopathy (3 eyes). Mean VA improved from 0.92 ± 0.16 (SD) logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.41 ± 0.27 logMAR. LogMAR at final follow-up was 0.41 ± 0.28 (P < .01). There were no cases of suture-related complications (erosion/breakage/granuloma) or IOL decentration throughout the follow-up period. CONCLUSIONS: Scleral fixation of IOLs with PTFE suture was found to be safe and well tolerated. All eyes had well-centered IOLs, with no suture-related complications during long-term follow-up. VA improved significantly with acceptable postoperative complications.
PURPOSE: To report intraoperative performance and long-term postoperative outcomes after scleral fixation of intraocular lenses (IOLs) with polytetrafluoroethylene suture (PTFE). SETTING: Raghudeep Eye Hospital, Ahmedabad, India. DESIGN: Prospective, interventional case series. METHODS: One hundred eyes undergoing scleral fixation of IOLs using PTFE suture (Gore-Tex) with 12 months or more postoperative follow-up were included. The primary outcome measures were occurrence of intraoperative and postoperative complications such as glaucoma, suture-related complications, and inflammation within the follow-up period. The secondary outcome measure was improvement in visual acuity (VA). RESULTS: Of the 100 eyes, posteriorly dislocated IOLs (53 eyes) followed by dropped nuclei (33 eyes) were the most common surgical indications. Mean follow-up was 23 months (range 12 months to 5 years). Seventy-one patients (77.17%) had 18 months or more follow-up; 21 eyes had a rise in intraocular pressure in the early postoperative period; 12 of them required glaucoma surgery. Early complications were vitreous hemorrhage in 13 eyes, retinal detachment in 6 eyes, and transient hyphema in 1 eye. Late postoperative complications were cystoid macular edema (9 eyes), epiretinal membrane (3 eyes), and bullous keratopathy (3 eyes). Mean VA improved from 0.92 ± 0.16 (SD) logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.41 ± 0.27 logMAR. LogMAR at final follow-up was 0.41 ± 0.28 (P < .01). There were no cases of suture-related complications (erosion/breakage/granuloma) or IOL decentration throughout the follow-up period. CONCLUSIONS: Scleral fixation of IOLs with PTFE suture was found to be safe and well tolerated. All eyes had well-centered IOLs, with no suture-related complications during long-term follow-up. VA improved significantly with acceptable postoperative complications.