Literature DB >> 3264924

A simple technique to measure regional cerebral blood flow during intravascular balloon clamping.

S Furuhata1, A Kubo, T Kawase, Y Ibata, S Toya.   

Abstract

A case of giant internal carotid ophthalmic aneurysm was presented. In order to clarify whether the patient could tolerate carotid occlusion, a balloon clamping test was performed. before surgery. The cerebral blood flow was measured using early imaging by single photon emission computed tomography (SPECT) with N-isopropyl-(iodine-123)-p-iodoamphetamine (123I-IMP). When the balloon clamping test was performed the tracer was injected, and scanning was performed 35 minutes after removing the catheter. This tracer enabled a "memory of blood flow" during temporary ischemia to determine the character of quick diffusion and slow wash out, that could not be performed by other methods of cerebral blood flow measurement. SPECT with 123I-IMP can simplify the measurement of cerebral blood flow during the balloon clamping test.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3264924     DOI: 10.3769/radioisotopes.37.6_336

Source DB:  PubMed          Journal:  Radioisotopes        ISSN: 0033-8303


  1 in total

1.  Angiographic circulation time and cerebral blood flow during balloon test occlusion of the internal carotid artery.

Authors:  Kenichi Sato; Hiroaki Shimizu; Takashi Inoue; Miki Fujimura; Yasushi Matsumoto; Ryushi Kondo; Hidenori Endo; Yukihiko Sonoda; Teiji Tominaga
Journal:  J Cereb Blood Flow Metab       Date:  2013-10-09       Impact factor: 6.200

  1 in total