| Literature DB >> 326442 |
M H Wood, D C Sampson, W J Hensley.
Abstract
A gas chromatographic method for the plasma assay of the anticonvulsant, sodium valproate, is described. Derivatization is not necessary. 200 microliter plasma are required for a single estimation. The method involves a chloroform extraction of valproate and the internal standard, cyclopentane carboxylic acid, from acidified plasma. Gas-liquid chromatography using the stationary phase 10% SP-216-PS gives complete separation of valproate and the internal standard in eight minutes. The limit of detection is 20 mumol valproate/1 plasma (equivalent to 40 pmol on column). This is well below the lower therapeutic plasma level. The between-run precision of the method indicates a variation for each sample within+/-3% of its mean value.Entities:
Mesh:
Substances:
Year: 1977 PMID: 326442 DOI: 10.1016/0009-8981(77)90239-x
Source DB: PubMed Journal: Clin Chim Acta ISSN: 0009-8981 Impact factor: 3.786