Literature DB >> 32637254

Spatio-temporal filtering in laser Doppler holography for retinal blood flow imaging.

Léo Puyo1,2, Michel Paques1,2, Michael Atlan3.   

Abstract

Laser Doppler holography (LDH) is a full-field interferometric imaging technique recently applied in ophthalmology to measure blood flow, a parameter of high clinical interest. From the temporal fluctuations of digital holograms acquired at ultrafast frame rates, LDH reveals retinal and choroidal blood flow with a few milliseconds of temporal resolution. However, LDH experiences difficulties to detect slower blood flow as it requires to work with low Doppler frequency shifts which are corrupted by eye motion. We here demonstrate the use of a spatio-temporal decomposition adapted from Doppler ultrasound that provides a basis appropriate to the discrimination of blood flow from eye motion. A singular value decomposition (SVD) can be used as a simple, robust, and efficient way to separate the Doppler fluctuations of blood flow from those of strong spatial coherence such as eye motion. We show that the SVD outperforms the conventional Fourier based filter to reveal slower blood flow, and dramatically improves the ability of LDH to reveal vessels of smaller size or with a pathologically reduced blood flow.
© 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2020        PMID: 32637254      PMCID: PMC7316027          DOI: 10.1364/BOE.392699

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  4 in total

1.  Photoplethysmographic analysis of retinal videodata based on the Fourier domain approach.

Authors:  Radim Kolář; Jan Odstrčilík; Ralf-Peter Tornow
Journal:  Biomed Opt Express       Date:  2021-11-09       Impact factor: 3.732

2.  Spatiotemporal processing in photoplethysmography for skin microcirculatory perfusion imaging.

Authors:  Dongkai Cheng; Jiabin Wang; Tomoyuki Yokota; Takao Someya
Journal:  Biomed Opt Express       Date:  2022-01-18       Impact factor: 3.732

3.  Performance optimisation of a holographic Fourier domain diffuse correlation spectroscopy instrument.

Authors:  Edward James; Samuel Powell; Peter Munro
Journal:  Biomed Opt Express       Date:  2022-06-09       Impact factor: 3.562

4.  Comparative analysis of wavelet transform filtering systems for noise reduction in ultrasound images.

Authors:  Dominik Vilimek; Jan Kubicek; Milos Golian; Rene Jaros; Radana Kahankova; Pavla Hanzlikova; Daniel Barvik; Alice Krestanova; Marek Penhaker; Martin Cerny; Ondrej Prokop; Marek Buzga
Journal:  PLoS One       Date:  2022-07-07       Impact factor: 3.752

  4 in total