Erqian Wang1,2, Youxin Chen1,2, Ningning Li1,3, Hanyi Min4,5.
Abstract
PURPOSE: To evaluate the effect of silicone oil (SO) on peripapillary blood flow using OCT angiography.Entities:
Keywords: Optic neuropathy; Optical coherence tomography angiography; Radial peripapillary capillaries; Rhegmatogenous retinal detachment; Silicone oil
Mesh:
Substances:
Year: 2020 PMID: 32635899 PMCID: PMC7339486 DOI: 10.1186/s12886-020-01533-7
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Measuring radial peripapillary capillaries (RPC) vessel density (VD) based on Garway-Heath’s map. (Left) The representative 4.5 mm × 4.5 mm en face OCT angiography image is centered on optic nerve head. The peripapillary area is overlaid by annular contour lines with 2 mm and 4 mm diameter around disc margin. The peripapillary area is further divided into eight sectors according to Garway-Heath’s map. (Right) The built-in software automatically calculates RPC VD based on Garway-Heath’s map. The global RPC VD (arrow) is measured from the 360-degree annular peripapillary area. The RPC VD of the superior (asterisk) and inferior (triangle) hemifield is measured from the superior four sectors and the inferior four sectors, respectively
Demographic and Clinical Characteristics (n = 22)
| Characteristics | Affected eye | Contralateral eye | |
|---|---|---|---|
| Age (Years) | 52.2 ± 12.3 | – | |
| Sex (Male/Female) | 15/7 | – | |
| Refractive Error (Diopters) | −2.5 ± 2.3 | −2.4 ± 2.3 | 0.72 |
| Axial Length (mm) | 24.81 ± 1.24 | 24.79 ± 1.29 | 0.86 |
| Macula Status (On/Off) | 3/19 | NA | NA |
| SO Removal Combined with Cataract Surgery (Yes/No) | 9/13 | NA | NA |
| SO Tamponade Duration (Days) | 101.3 ± 8.4 | NA | NA |
| Full SO Tamponadea (Yes/No) | 15/7 | NA | NA |
Age, refractive error, and axial length are shown as mean ± standard deviation
*P values are from Wilcoxon signed ranks test for continuous variables
aSilicone oil tamponade is deemed as full if oil-water interface is not visible under indirect ophthalmoscope after pupil dilation
SO silicone oil, NA not applicable
Comparison of Peripapillary Vessel Density Changes After Silicone Oil Removal Between Affected and Contralateral Eyes (n = 22)
| Measurements | Affected eyes | Contralateral eyes | |
|---|---|---|---|
| Global RPC VD | Before SOR | 46.8 ± 3.7% | 51.0 ± 3.3% |
| After SOR | 48.1 ± 3.8% | 50.6 ± 3.4% | |
| Change | 1.3% (0.3 to 2.3%) | − 0.4% (− 1.4 to 0.7%) | |
| Difference of changea | 1.9% (0.6 to 3.2%), | ||
| Superior RPC VD | Before SOR | 46.8 ± 3.9% | 51.1 ± 3.8% |
| After SOR | 48.4 ± 3.6% | 50.8 ± 3.8% | |
| Change | 1.6% (0.6 to 2.7%) | −0.4% (−1.4 to 0.7%) | |
| Difference of changea | 2.2% (0.9 to 3.4%), | ||
| Inferior RPC VD | Before SOR | 46.7 ± 4.3% | 50.8 ± 3.2% |
| After SOR | 47.7 ± 4.4% | 50.4 ± 3.5% | |
| Change | 1.0% (−0.2 to 2.1%) | −0.4% (−1.5 to 0.7%) | |
| Difference of changea | 1.6% (−0.0 to 3.2%), | ||
Vessel densities before and after silicone oil removal are described as mean ± SD
Changes in vessel densities are described as mean (95% confidence interval)
aDifference of change in vessel densities between affected and contralateral eyes was analyzed using mixed model analysis and presented as mean (95% confidence interval). The P value represents the main effect of SOR with changes in intraocular pressure and OCT angiography image quality score adjusted as covariates
RPC Radial Peripapillary Capillaries, VD Vessel Density, SOR Silicone Oil Removal
Fig. 2The whisker plot of global radial peripapillary capillaries (RPC) vessel density (VD) measured before and at 10 days, 1 month and 3 months after silicone oil removal (SOR) in patients who underwent pars plana vitrectomy and silicone oil tamponade for rhegmatogenous retinal detachment repair. The mean, median, and 25th to 75th percentile of RPC VD is shown by cross, horizontal line, and box, respectively. An increase in peripapillary vessel density after SOR is revealed by repeated measures ANOVA (F = 5.417, P = 0.002). The results of Bonferroni’s post hoc test are indicated by P values above horizontal bars