Anne Bouwhuis1,2, Patrick Schober2, Leo M A Heunks1, Lothar A Schwarte3.
Abstract
OBJECTIVE: Objective of this case report is to draw attention to a less known thrombotic complication associated with COVID-19, i.e., thrombosis of both radial arteries, with possible (long-term) consequences. THE CASE: In our COVID-19 ICU a 49-year-old male patient was admitted, with past medical history of obesity, smoking and diabetes, but no reported atherosclerotic complications. The patient had been admitted with severe hypoxemia and multiple pulmonary emboli were CT-confirmed. ICU-treatment included mechanical ventilation and therapeutic anticoagulation. Preparing the insertion of a new radial artery catheter for invasive blood pressure measurement and blood sampling, we detected that both radial arteries were non-pulsating and occluded: (a) Sonography showed the typical anatomical localization of both radial and ulnar arteries. However, Doppler-derived flow-signals could only be obtained from the ulnar arteries. (b) To test collateral arterial supply of the hand, a pulse-oximeter was placed on the index finger. Thereafter, the ulnar artery at the wrist was compressed. This compression caused an immediate loss of the finger's pulse-oximetry perfusion signal. The effect was reversible upon release of the ulnar artery. (c) To test for collateral perfusion undetectable by pulse-oximetry, we measured regional oxygen saturation (rSO2) of the thenar muscle by near-infrared spectroscopy (NIRS). Confirming our findings above, ulnar arterial compression demonstrated that thenar rSO2 was dependent on ulnar artery flow. The described development of bilateral radial artery occlusion in a relatively young and therapeutically anticoagulated patient with no history of atherosclerosis was unexpected.Entities:
Keywords: Artery; COVID-19; Occlusion; Radial; Thrombosis
Mesh:
Year: 2020 PMID: 32632667 PMCID: PMC7335765 DOI: 10.1007/s10877-020-00555-2
Source DB: PubMed Journal: J Clin Monit Comput ISSN: 1387-1307 Impact factor: 2.502
Fig. 1a–c Doppler flow signals were absent in both radial arteries, but present in both ulnar arteries (a). In line with this, finger-clip pulse-oximetry waveforms were lost after compression of an ulnar artery (b) confirming dependency of the hand’s perfusion on the ulnar artery. This is also confirmed by impaired regional thenar muscle oxygen saturation (rSO2, measured by near-infrared spectroscopy, NIRS, Nonin-SenSmart®) after selective ulnar artery compression (c): In the described COVID-19 patient, selective compression of the right ulnar artery (starting at ~ 60 s) induced a marked drop in NIRS-measured rSO2, leveling off after 3 min of ischemia (starting at ~ 240 s). After reaching stable, low values, the compression of the ulnar artery was released (at ~ 340 s), resulting in a rapid recovery of rSO2 and return to baseline thenar rSO2