Literature DB >> 32622802

Assessment of Tendon Retraction in Large to Massive Rotator Cuff Tears: A Modified Patte Classification Based on 2 Coronal Sections on Preoperative Magnetic Resonance Imaging With Higher Specificity on Predicting Reparability.

Siyi Guo1, Yiming Zhu1, Guanyang Song1, Chunyan Jiang2.   

Abstract

PURPOSE: To propose a modified Patte classification (evaluating tendon retraction on 2 coronal sections) and analyze whether this classification was better at predicting irreparability and retear of large to massive rotator cuff tears (RCTs).
METHODS: A retrospective study was performed. Imaging evaluation including tendon retraction, fatty infiltration, the acromiohumeral distance (AHD), and the tangent sign was performed using magnetic resonance imaging. The modified Patte classification was used to assess tendon retraction. Intraobserver and interobserver reliability was analyzed by calculating intraclass correlation coefficients. Factors affecting irreparability and retear were analyzed using both univariate and multivariate analyses. Sensitivity and specificity of tendon retraction to predict irreparability and retear were calculated.
RESULTS: A total of 121 shoulders with large to massive RCTs underwent arthroscopic rotator cuff repairs. The modified Patte classification system had excellent interobserver and intraobserver reliability. Several factors were associated with reparability and retear in the univariate analysis. However, in binary logistic regression analysis, the only factors affecting reparability were AHD less than 0.4 cm (P = .007) and modified Patte stage III tendon retraction (P = .023). Low-grade repair quality (P = .001) and modified Patte stage III tendon retraction (P = .031) were independent factors for retear. Modified Patte stage III had a high specificity for predicting irreparability (93.58%) and retear (98.78%), whereas the specificity of original Patte stage III was 76.15% and 84.15%, respectively.
CONCLUSIONS: For large to massive RCT repairs, modified Patte stage III tendon retraction with evaluation of 2 coronal cuts reveals higher specificity on predicting tendon irreparability and postoperative retear. An AHD less than 0.4 cm on magnetic resonance imaging and modified Patte stage III tendon retraction were independent risk factors for irreparability. Low-grade repair quality and modified Patte stage III tendon retraction were independent risk factors for postoperative retear. LEVEL OF EVIDENCE: Level III, case-control study.
Copyright © 2020 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2020        PMID: 32622802     DOI: 10.1016/j.arthro.2020.06.023

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  2 in total

1.  Transosseous repair with a cortical implant for greater tubercle cyst-related rotator cuff tear results in good clinical outcomes, but significant implant migration.

Authors:  Mustafa Aydın; Enejd Veizi; Şahin Çepni; Ali Şahin; Ahmet Fırat
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-04-02       Impact factor: 4.114

Review 2.  Understanding shoulder pseudoparalysis: Part I: Definition to diagnosis.

Authors:  Stefan Bauer; Taro Okamoto; Stephanie M Babic; Jonathon C Coward; Charline M P L Coron; William G Blakeney
Journal:  EFORT Open Rev       Date:  2022-03-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.