Literature DB >> 32622715

MARS MRI Characteristics of Adverse Local Tissue Reactions in Taper Corrosion of Metal-On-Polyethylene THA Differ From Metal-On-Metal THA.

John Mahajan1, Bryant Bonner1, Ruben Oganesyan1, Ingwon Yeo1, Christian Klemt1, Young-Min Kwon1.   

Abstract

BACKGROUND: Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has been recommended as a cross-sectional imaging modality in clinical evaluation of adverse local tissue reactions (ALTRs) in metal-on-metal (MoM) patients and metal-on-polyethylene (MoP) patients with taper corrosion. The aim of the study was to compare MARS MRI characteristics of ALTR in MoM total hip arthroplasty (THA) with ALTR in MoP THA with modular taper corrosion.
METHODS: A total of 197 patients with ALTR were evaluated: 86 patients with MoM THA; 37 MoP patients with head-neck taper corrosion; and 74 MoP patients with neck-stem dual taper corrosion. MARS MRI scans were evaluated to identify location, size, type of ALTR (I-III), and associated ALTR synovitis (cystic, solid, and mixed).
RESULTS: MARS MRI characteristics of ALTR were significantly different between the MoM and MoP groups (P = .017). The MoP group demonstrated the highest proportion of thick-walled cystic masses type II (56.7% in head-neck taper corrosion MoP and 46.5% in dual taper corrosion MoP vs 28.7% in MoM), whereas the MoM group had the highest proportion of thin-walled cystic masses type I. MoM implants (96.8%) were significantly more likely to have ALTR in multiple locations compared with both MoP groups (P = .001).
CONCLUSION: This study demonstrates that MARS MRI characteristics of ALTR differ by bearing type with a significantly higher percentage of mixed type and solid type ALTR in the taper corrosion MoP THA compared with MoM THA. This information provides clinically useful information in evaluation of symptomatic MoP and MoM THA patients for ALTRs.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  MARS MRI; adverse local tissue reaction; metal-on-metal total hip arthroplasty; metal-on-polyethylene total hip arthroplasty; taper corrosion

Mesh:

Substances:

Year:  2020        PMID: 32622715     DOI: 10.1016/j.arth.2020.06.010

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

1.  Outcome and risk factors of failures associated with revision total hip arthroplasty for recurrent dislocation.

Authors:  Christian Klemt; Wenhao Chen; Georges Bounajem; Venkatsaiakhil Tirumala; Liang Xiong; Young-Min Kwon
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-18       Impact factor: 2.928

Review 2.  Imaging in Hip Arthroplasty Management Part 2: Postoperative Diagnostic Imaging Strategy.

Authors:  Charles Lombard; Pierre Gillet; Edouard Germain; Fatma Boubaker; Alain Blum; Pedro Augusto Gondim Teixeira; Romain Gillet
Journal:  J Clin Med       Date:  2022-07-29       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.