Ability of 24-2C and 24-2 Grids to Identify Central Visual Field Defects and Structure-Function Concordance in Glaucoma and Suspects.

Jack Phu1, Michael Kalloniatis2.   

Abstract

PURPOSE: The purpose of this study was to compare the ability of the 24-2 test grid with that of the 24-2C test grid to measure visual field global indices, identify central visual field defects, and facilitate macular structure-function analysis with optical coherence tomography (OCT) scans in glaucoma suspects and glaucoma patients.
DESIGN: Prospective, cross-sectional study.
METHODS: One eye from each of 100 glaucoma suspects and glaucoma patients (60 undergoing SITA-Faster [Zeiss Meditec] testing on 24-2 and 24-2C; 40 undergoing SITA-Standard [Zeiss Meditec] testing on 24-2 and SITA-Faster on 24-2C) were included in the study. Global visual field indices, test duration, and pattern deviation results were extracted. The deviation map from the Cirrus OCT (Carl Zeiss Meditec) Ganglion Cell Analysis (GCA) was extracted, and structure-function relationships were compared after correction of the visual field test stimulus location that stimulated the corresponding retinal ganglion cell.
RESULTS: Global index results of the 24-2 grid were similar to those of the 24-2C grid, and both identified a comparable number of clusters of visual field defects. Centrally, the 24-2C grid identified more clusters of defects than the 24-2 grid, but this was not statistically significant. Although the 24-2C test locations resulted in more instances of structure-function concordance than the 24-2 locations, half the locations in the 24-2C grid fell close to or outside the GCA grid when corrected for ganglion cell displacement.
CONCLUSIONS: The 24-2C returned global visual field indices similar to the 24-2 grid but tended to identify more clusters of central functional defects. Central structure-function concordance was better achieved using the 24-2C grid, but half of the visual field test locations did not coincide with the commonly used macular thickness scan.
Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2020        PMID: 32621896     DOI: 10.1016/j.ajo.2020.06.024

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  7 in total

1.  Functional characteristics of glaucoma related arcuate defects seen on OCT en face visualisation of the retinal nerve fibre layer.

Authors:  Bright S Ashimatey; Brett J King; William H Swanson
Journal:  Ophthalmic Physiol Opt       Date:  2021-01-25       Impact factor: 3.117

2.  Agreement Between 10-2 and 24-2C Visual Field Test Protocols for Detecting Glaucomatous Central Visual Field Defects.

Authors:  Tutul Chakravarti; Mohamad Moghadam; James A Proudfoot; Robert N Weinreb; Christopher Bowd; Linda M Zangwill
Journal:  J Glaucoma       Date:  2021-06-01       Impact factor: 2.290

3.  Simultaneously performed combined 24-2 and 10-2 visual field tests in glaucoma.

Authors:  Kyoung In Jung; Hee Kyung Ryu; Ki Hoon Hong; Yong Chan Kim; Chan Kee Park
Journal:  Sci Rep       Date:  2021-01-13       Impact factor: 4.379

4.  Increasing the Spatial Resolution of Visual Field Tests Without Increasing Test Duration: An Evaluation of ARREST.

Authors:  Vasanth Muthusamy; Andrew Turpin; Mark J Walland; Bao N Nguyen; Allison M McKendrick
Journal:  Transl Vis Sci Technol       Date:  2020-12-16       Impact factor: 3.283

5.  A Novel Stimulus to Improve Perimetric Sampling within the Macula in Patients with Glaucoma.

Authors:  Muhammed S Alluwimi; William H Swanson; Brett J King
Journal:  Optom Vis Sci       Date:  2021-04-01       Impact factor: 2.106

6.  The Frontloading Fields Study (FFS): Detecting Changes in Mean Deviation in Glaucoma Using Multiple Visual Field Tests Per Clinical Visit.

Authors:  Jack Phu; Michael Kalloniatis
Journal:  Transl Vis Sci Technol       Date:  2021-11-01       Impact factor: 3.283

7.  The Frontloading Fields Study: The Impact of False Positives and Seeding Point Errors on Visual Field Reliability When Using SITA-Faster.

Authors:  Jack Phu; Michael Kalloniatis
Journal:  Transl Vis Sci Technol       Date:  2022-02-01       Impact factor: 3.283

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.