Literature DB >> 32621018

Evaluation of the effect of fasting on intraocular pressure, anterior segment parameters and density of crystalline lens and cornea.

Abdullah Beyoğlu1, Yalcin Karakucuk2, Ayşegül Çömez3.   

Abstract

PURPOSE: To evaluate the effect of fasting on anterior chamber depth, anterior chamber volume and corneal and lens density by Scheimpflug technology and to measure intraocular pressure changes.
METHODS: Totals of 50 healthy fasting individuals in Ramadan (study group) and 50 healthy non-fasting subjects (control group) were included. Central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), corneal density (CD) and lens density (LD) were evaluated with Scheimpflug technology. Intraocular pressure (IOP) was measured with applanation tonometry. Both eyes of each participant were examined and also compared.
RESULTS: Comparison of groups: There was a statistically significant difference between CD, ACD, ACV and IOP (respectively, right/left eye: fasting: CD: 12.81 ± 0.76/12.73 ± 0.73; ACD: 2.92 ± 0.37 mm/2.93 ± 0.37 mm; ACV: 168.3 ± 41.82 mm3/183.34 ± 32.46 mm3; IOP: 13.80 ± 1.22 mmHg/14.88 ± 2.73 mmHg; non-fasting: CD: 13.28 ± 1.01/13.17 ± 0.77; ACD: 3.06 ± 0.31 mm/3.07 ± 0.31 mm; ACV: 167.46 ± 42.92 mm3/180.68 ± 31.45 mm3; IOP: 13.60 ± 1.65 mmHg/14.74 ± 2.93 mmHg) values on the right side (p < 0.01, p = 0.03, p = 0.04, p = 0.01, respectively). Although there was a statistically significant difference between the ACV, CD and IOP values on the left side (p < 0.01, p = 0.03, p = 0.01, respectively), no statistical significance was found for the ACV value on the left side (p = 0.08).
CONCLUSION: The results demonstrated that, while fasting did not lead to any change in LD and CCT, it caused a small decrease in ACD and ACV, and a significant decrease in CD and IOP values. Scheimpflug technology seems to be a valuable tool for the evaluation of anterior segment changes in patients who are fasting.

Entities:  

Keywords:  Corneal density; Dehydration; Fasting; Lens density; Scheimpflug technology; İntraocular pressure

Mesh:

Year:  2020        PMID: 32621018     DOI: 10.1007/s10792-020-01482-6

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  2 in total

1.  Evaluation of the Effect of Religious Fasting on Retinal Vessel Density and Retinal Thickness Using Optical Coherence Tomography Angiography.

Authors:  Saeed Shokoohi-Rad; Nasser Shoeibi; Mohammad Ghasemi Nour; Elham Bakhtiari
Journal:  Neuroophthalmology       Date:  2021-11-04

Review 2.  Intermittent Fasting to the Eye: A New Dimension Involved in Physiological and Pathological Changes.

Authors:  Jiaqing Feng; Shijiao Zhang; Wenning Li; Tianle Bai; Yulin Liu; Xingyu Chang
Journal:  Front Med (Lausanne)       Date:  2022-05-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.