Bo Zhang1,2, Leitao Yu3, Zhenjiang Liu1, Hongyang Lu2, Xiaoling Fu3, Daolin Du1.
Abstract
The study aimed to establish a automated versatile sample preconcentration method based on the modified immunomagnetic beads, which was utilized to enrich for aflatoxin B1 from the matrices. The critical main parameters affecting the extraction efficiency, such as usage amount of immunomagnetic beads, reaction time, elution time, blending way was investigated. Under the optimized conditions, the content of aflatoxin B1 was analyzed using the high performance liquid chromatography, the mobile phase consists of water:acetonitrile:methanol (42:18:10, v/v/v) and fluorescence detection was performed with excitation and emission wavelengths at 360nm and 440nm, respectively. Moreover, the performance of preconcentration method was compared with the conventional method based on the immunoaffinity column. The accuracy of two clean-up methods was within the error range. In addition, the stability and recyclability of immunomagnetic beads was studied by recycling for five times. The results for the respective analysis in various samples demonstrated that the developed extraction platform provide a promising approach for simple, rapid, sensitive and easy-to-use. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.Entities:
Keywords: aflatoxin B1; high performance liquid chromatography; immunomagnetic beads; sample pretreatment
Year: 2020 PMID: 32620032 DOI: 10.1002/jssc.202000293