Literature DB >> 32619755

Relation between age and CT radiation doses: Dose trends in 705 pediatric head CT.

Mohammad Hassan Kharita1, Huda Al-Naemi1, Chiara Arru2, Ahmed Jenaid Omar1, Antar Aly1, Ioannis Tsalafoutas1, Shady Alkhazzam1, Ramandeep Singh3, Mannudeep K Kalra3.   

Abstract

PURPOSE: To evaluate the relationship between patient age and radiation doses associated with routine pediatric head CT performed with automatic tube potential selection and tube current modulation techniques.
METHODS: We obtained patient demographics, scan parameters, and radiation dose descriptors (CT dose index volume -CTDIvol and dose length product -DLP) associated with consecutive routine head CT in 705 children (mean age 6.9 ± 5 years). Children were scanned on one of the three multidetector-row CTs (64-128 slices, Siemens) over 6 months period in a tertiary hospital. All head CT exams were performed in helical scan mode using automatic tube potential selection (Care kV) and automatic tube current modulation (Care Dose 4D) techniques. The information was obtained from a radiation dose monitoring software. Data were analyzed using linear correlation and analysis of variance.
RESULTS: Most age-wise median CTDIvol (9-27 mGy; 703/705 pediatric head CT, >99 %) from our institution were lower than the European Diagnostic Reference Levels (EDRL, CTDIvol 24-50 mGy) but median DLP (151-586 mGy cm) from 201/705 children (28 %) was higher than the EDRL (DLP 300-650 mGy cm). Unlike the age-stratified EDRL, a combination of automatic tube potential selection and tube current modulation for pediatric head results in a significant linear correlation between radiation doses and patient age (r2 = 0.66, p < 0.001).
CONCLUSIONS: Radiation doses for head CT change linearly with children's age. Despite lower CTDIvol and DLP for most children, longer scan length resulted in higher DLP for some pediatric head CT compared to the corresponding EDRL; this result underscores the need to promote clear guidelines for technologists operating CT.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Age; CT head; Children; Diagnostic reference levels (DRL); Radiation dose

Mesh:

Year:  2020        PMID: 32619755     DOI: 10.1016/j.ejrad.2020.109138

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  1 in total

1.  Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables.

Authors:  Yusuke Inoue; Hiroyasu Itoh; Anri Waga; Ryosuke Sasa; Kohei Mitsui
Journal:  Tomography       Date:  2022-04-01
  1 in total