Literature DB >> 32617731

Cinematic rendering enhancements to virtual bronchoscopy: assessment of emergent tracheal pathology.

Cheng Ting Lin1, Steven Rowe2, Linda C Chu2, Hannah Recht2, Elliot K Fishman2.   

Abstract

Utilizing complex lighting models, cinematic rendering is a novel technique for demonstrating computed tomography data with exquisite 3D anatomic detail. The tracheal lumen, tracheal wall, and adjacent soft tissue structures are represented with photorealistic detail exceeding that of conventional volume rendering or virtual bronchoscopy techniques. We applied cinematic rendering to a spectrum of emergent tracheal pathologies: traumatic tracheal tears, tracheoesophageal fistulas, tracheal foreign bodies, tracheal stenosis (intrinsic and extrinsic causes), tracheal neoplasms, and tracheomalacia. Cinematic rendering images enable visually accessible evaluation and comprehensive understanding of acute tracheal pathology, which is likely to be of value to both interventional pulmonologists and thoracic surgeons who are determining patient treatment plans.

Entities:  

Keywords:  Cinematic rendering; Tracheal emergencies; Tracheal stenosis; Tracheomalacia; Virtual bronchoscopy

Mesh:

Year:  2020        PMID: 32617731     DOI: 10.1007/s10140-020-01816-y

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  11 in total

1.  Radiologic evaluation of the trachea.

Authors:  Seth Kligerman; Amita Sharma
Journal:  Semin Thorac Cardiovasc Surg       Date:  2009

2.  Virtual bronchoscopy: segmentation method for real-time display.

Authors:  R M Summers; D H Feng; S M Holland; M C Sneller; J H Shelhamer
Journal:  Radiology       Date:  1996-09       Impact factor: 11.105

3.  Virtual bronchoscopy for three--dimensional pulmonary image assessment: state of the art and future needs.

Authors:  W E Higgins; K Ramaswamy; R D Swift; G McLennan; E A Hoffman
Journal:  Radiographics       Date:  1998 May-Jun       Impact factor: 5.333

Review 4.  Cinematic Rendering in CT: A Novel, Lifelike 3D Visualization Technique.

Authors:  Marwen Eid; Carlo N De Cecco; John W Nance; Damiano Caruso; Moritz H Albrecht; Adam J Spandorfer; Domenico De Santis; Akos Varga-Szemes; U Joseph Schoepf
Journal:  AJR Am J Roentgenol       Date:  2017-05-15       Impact factor: 3.959

5.  Initial experience with cinematic rendering for chest cardiovascular imaging.

Authors:  Steven P Rowe; Pamela T Johnson; Elliot K Fishman
Journal:  Br J Radiol       Date:  2017-10-27       Impact factor: 3.039

6.  MDCT of ductus diverticulum: 3D cinematic rendering to enhance understanding of anatomic configuration and avoid misinterpretation as traumatic aortic injury.

Authors:  Steven P Rowe; Pamela T Johnson; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2018-01-11

Review 7.  Update on multidetector computed tomography imaging of the airways.

Authors:  Karen S Lee; Phillip M Boiselle
Journal:  J Thorac Imaging       Date:  2010-05       Impact factor: 3.000

8.  Cinematic rendering of cardiac CT volumetric data: Principles and initial observations.

Authors:  Steven P Rowe; Pamela T Johnson; Elliot K Fishman
Journal:  J Cardiovasc Comput Tomogr       Date:  2017-12-02

9.  Evaluation of Kawasaki's disease-associated coronary artery aneurysms with 3D CT cinematic rendering.

Authors:  Steven P Rowe; Stefan L Zimmerman; Pamela T Johnson; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2018-02-27

Review 10.  Cinematic rendering - an alternative to volume rendering for 3D computed tomography imaging.

Authors:  Evelyn Dappa; Kai Higashigaito; Jürgen Fornaro; Sebastian Leschka; Simon Wildermuth; Hatem Alkadhi
Journal:  Insights Imaging       Date:  2016-09-15
View more
  1 in total

1.  Global illumination rendering versus volume rendering for the forensic evaluation of stab wounds using computed tomography.

Authors:  Wataru Fukumoto; Nobuo Kitera; Hidenori Mitani; Takahiro Sueoka; Shota Kondo; Ikuo Kawashita; Yuko Nakamura; Masataka Nagao; Kazuo Awai
Journal:  Sci Rep       Date:  2022-02-14       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.