Total body irradiation in Australia and New Zealand: results of a practice survey.

Lotte S Fog1, Andrew Wirth2, Michael MacManus2, Simon Downes3, Michael Grace4, Alicia Moggré5, Koki Mugabe6, Gabor Neveri7, Lisa Nourbehesht8, Vanessa Panettieri9, Dane Pope10, Lucy Sim11, Cameron Stanton12, Blair Steer13, Allan Stewart14, Elena Ungureanu2, Tomas Kron2.   

Abstract

Total body irradiation (TBI) is an important treatment modality for the preparation of patients for bone marrow transplants. It is technically challenging and the actual delivery may vary from clinic to clinic. Knowledge of the pattern of practice may be helpful for clinics to determine future practice. We carried out an email survey from April to September 2019 sending 48 TBI related questions to all radiotherapy clinics in Australia and New Zealand via the Australasian College of Physical Scientists in Medicine email distribution list. Centres not performing TBI were not expected to complete the survey and centres that had participated in a previous survey, or that were known to perform the treatment, were followed up if no response was received. Of a total of approximately 70 centres, 14 clinics responded to the survey. The vast majority of clinics use conventional lateral and/or anterior-posterior beams at extended SSD for TBI treatment delivery. However, treatment planning, ancillary equipment (used for immobilisation/modulation), beam energy and prescribed lung doses vary considerably-with some clinics delivering the prescription dose to the lungs and some aiming to deliver a lung dose which is lower than the prescription dose. Only one clinic reported using an advanced delivery technique with modulated arcs at extended SSD. Centres either said they had no access to outcome data or did not answer this question. Compared with an earlier survey from 2005, 3 clinics have lowered their linac dose rate and 7 are the same or similar. The TBI practice in Australia and New Zealand remains varied, with considerable differences in treatment planning, beam energy, accepted lung doses and delivered dose rates.

Entities:  

Keywords:  Australia; Bone marrow transplant; Lung dose; New zealand; Total body irradiation; Treatment planning

Mesh:

Year:  2020        PMID: 32613526     DOI: 10.1007/s13246-020-00878-z

Source DB:  PubMed          Journal:  Phys Eng Sci Med        ISSN: 2662-4729


  3 in total

1.  Total Body Irradiation and Total Skin Irradiation Techniques in Belgium and the Netherlands: Current Clinical Practice.

Authors:  Phil W Koken; Lars H P Murrer
Journal:  Adv Radiat Oncol       Date:  2021-02-09

Review 2.  Total Body Irradiation in Haematopoietic Stem Cell Transplantation for Paediatric Acute Lymphoblastic Leukaemia: Review of the Literature and Future Directions.

Authors:  Bianca A W Hoeben; Jeffrey Y C Wong; Lotte S Fog; Christoph Losert; Andrea R Filippi; Søren M Bentzen; Adriana Balduzzi; Lena Specht
Journal:  Front Pediatr       Date:  2021-12-03       Impact factor: 3.418

3.  Three-dimensional printers applied for the production of beam blocks in total body irradiation treatment.

Authors:  Manuel Maerz; Marius Treutwein; Jan Nabo; Barbara Dobler
Journal:  J Appl Clin Med Phys       Date:  2022-03-15       Impact factor: 2.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.