| Literature DB >> 32610531 |
Antonio Bevilacqua1, Barbara Speranza1, Daniela Campaniello1, Milena Sinigaglia1, Maria Rosaria Corbo1.
Abstract
A user friendly spreadsheet (Excel interface), designated MoS (Micro-Olive-Spreadsheet), is proposed in this paper as a tool to point out spoiling phenomena in Bella di Cerignola olive brines. The spreadsheet was designed as a protected Excel worksheet, where users input values for the microbiological criteria and pH of brines, and the output is a visual code, much like a traffic light: three red cells indicate a spoiling event, while two red cells indicate the possibility of a spoiling event. The input values are: a) Total Aerobic Count (TAC); b) Lactic Acid Bacteria (LAB); c) yeasts; d) staphylococci; e) pH. TAC, LAB, yeasts, and pH are the input values for the first section (quality), while staphylococci count is the input for the second section (technological history). The worksheet can be modified by adding other indices or by setting different breakpoints; however, it is a simple tool for an effective application of hazard analysis and predictive microbiology in table olive production.Entities:
Keywords: Bella di Cerignola; brines; microbiological quality; producers; table olives; user-friendly spreadsheet
Year: 2020 PMID: 32610531 PMCID: PMC7404787 DOI: 10.3390/foods9070848
Source DB: PubMed Journal: Foods ISSN: 2304-8158
Figure 1Total Aerobic Count (TAC) (A), Lactic Acid Bacteria (LAB) (B), ratio LAB vs. TAC (C), yeasts (D), and staphylococci in brines (E). sp, spoiled samples, no-sp, non-spoiled samples. ▫ Mean; □, Mean ± SE; ◦ Outliers; * extremes; bars denote 95% confidence interval.
Figure 2Input and Output of MoS.
Figure 3Section of spreadsheet for quality parameters.
Decision criteria for MoS (Micro-Olive-Spreadsheet) and respective equations and outcomes.
| Decision Criteria (Questions) | Equations | Yes | No |
|---|---|---|---|
|
| |||
|
| LAB < 1% TAC | Not acceptable | Acceptable |
|
| Yeast > 5 | Not acceptable | Acceptable |
|
| pH > 4.5 | Not acceptable | Acceptable |
|
| |||
|
| Staph > 4 | Incorrect handling | - |
|
| Salt < 8% | Possible corrective measures | - |
TAC, total aerobic count; LAB, lactic acid bacteria; staph, staphylococci. Bacterial concentrations of brines are reported as log CFU/mL.
Figure 4Section of spreadsheet on technological history.
Figure 5Section of spreadsheet for salt concentration in brine.
Decision on the samples used for the validation.
| Sample | Decision by Panel | Comments | TAC | LAB | Yeasts | pH | Spreadsheet |
|---|---|---|---|---|---|---|---|
| 1 | Acceptable | Typical odor of Spanish-style olives | 2.01 | 6.65 | 4.18 | 4.05 | Acceptable |
| 2 | Not acceptable | Off-odors | 5.99 | 3.73 | 6.01 | 5.15 | Not acceptable |
| 3 | Not acceptable | Off-odors | 6.14 | 5.93 | 6.14 | 5.27 | Attention |
| 4 | Acceptable, but the sample has some problems | Films on the surface | 5.45 | 5.08 | 7.26 | 5.35 | Attention |
| 5 | Acceptable, but the sample has some problems | Strong odor | 5.53 | 2.23 | 3.46 | 4.67 | Attention |
| 6 | Acceptable | - | 4.64 | 7.66 | 3.10 | 4.23 | Acceptable |
| 7 | Acceptable, but the sample has some problems | Fruity odor is too strong | 4.82 | 7.63 | 5.87 | 4.85 | Attention |
| 8 | Acceptable | - | 4.56 | 6.12 | 4.53 | 4.43 | Acceptable |
| 9 | Acceptable | - | 4.31 | 5.99 | 3.56 | 4.36 | Acceptable |
| 10 | Not acceptable | Films on the surface | 7.80 | 5.79 | 6.01 | 4.67 | Not acceptable |
| 11 | Not acceptable | Off-odors | 5.99 | 2.34 | 5.31 | 4.89 | Not acceptable |
| 12 | Acceptable | - | 5.53 | 6.48 | 2.83 | 4.43 | Acceptable |
TAC, total aerobic count; LAB, lactic acid bacteria. The unit of counts is log CFU/mL.
Figure 6Traffic light for spoiled (sample 2) and acceptable samples (sample 6).