Literature DB >> 32601509

Ultra-portable field transfer radiometer for vicarious calibration of earth imaging sensors.

Kurtis Thome1, Brian Wenny2, Nikolaus Anderson3, Joel McCorkel1, Jeffrey Czapla-Myers3, Stuart Biggar3.   

Abstract

A small portable transfer radiometer has been developed as part of an effort to ensure the quality of upwelling radiance from test sites used for vicarious calibration in the solar reflective. The test sites are used to predict top-of-atmosphere reflectance relying on ground-based measurements of the atmosphere and surface. The portable transfer radiometer is designed for one-person operation for on-site field calibration of instrumentation used to determine ground-leaving radiance. The current work describes the detector- and source-based radiometric calibration of the transfer radiometer highlighting the expected accuracy and SI-traceability. The results indicate differences between the detector-based and source-based results greater than the combined uncertainties of the approaches. Results from recent field deployments of the transfer radiometer using a solar radiation based calibration agree with the source-based laboratory calibration within the combined uncertainties of the methods. The detector-based results show a significant difference to the solar-based calibration. The source-based calibration is used as the basis for a radiance-based calibration of the Landsat-8 Operational Land Imager that agrees with the OLI calibration to within the uncertainties of the methods.

Entities:  

Year:  2018        PMID: 32601509      PMCID: PMC7323731          DOI: 10.1088/1681-7575/aab311

Source DB:  PubMed          Journal:  Metrologia        ISSN: 0026-1394            Impact factor:   3.157


  6 in total

1.  Facility for spectral irradiance and radiance responsivity calibrations using uniform sources.

Authors:  Steven W Brown; George P Eppeldauer; Keith R Lykke
Journal:  Appl Opt       Date:  2006-11-10       Impact factor: 1.980

2.  SeaWiFS transfer-to-orbit experiment.

Authors:  R A Barnes; R E Eplee; S F Biggar; K J Thome; E F Zalewski; P N Slater; A W Holmes
Journal:  Appl Opt       Date:  2000-10-20       Impact factor: 1.980

3.  Short-wave infrared transfer radiometer for the calibration of the moderate-resolution imaging spectrometer and the advanced spaceborne thermal emission and reflection radiometer.

Authors:  P R Spyak; D S Smith; J Thiry; C Burkhart
Journal:  Appl Opt       Date:  2000-11-01       Impact factor: 1.980

4.  Aircraft measurements for calibration of an orbiting spacecraft sensor.

Authors:  W A Hovis; J S Knoll; G R Smith
Journal:  Appl Opt       Date:  1985-02-01       Impact factor: 1.980

5.  Design and calibration of field deployable ground-viewing radiometers.

Authors:  Nikolaus Anderson; Jeffrey Czapla-Myers; Nathan Leisso; Stuart Biggar; Charles Burkhart; Rob Kingston; Kurtis Thome
Journal:  Appl Opt       Date:  2013-01-10       Impact factor: 1.980

6.  Comparison of two methodologies for calibrating satellite instruments in the visible and near-infrared.

Authors:  Robert A Barnes; Steven W Brown; Keith R Lykke; Bruce Guenther; James J Butler; Thomas Schwarting; Kevin Turpie; David Moyer; Frank DeLuccia; Christopher Moeller
Journal:  Appl Opt       Date:  2015-12-10       Impact factor: 1.980

  6 in total