Literature DB >> 32598095

Effect of zirconia decontamination protocols on bond strength and surface wettability.

Mayara Dos Santos Noronha1, Bruna Marin Fronza2, Carolina Bosso André3, Eduardo Fernandes de Castro1, Jorge Soto-Montero1,4, Richard Bengt Price5, Marcelo Giannini1.   

Abstract

OBJECTIVE: To evaluate the effects of human saliva decontamination protocols on bond strength of resin cement to zirconia (Y-PSZ), wettability, and microbial decontamination.
MATERIALS AND METHODS: Zirconia plates were sandblasted and divided into (a) not contaminated, (b) contaminated with human saliva and: (c) not cleaned, (d) cleaned with air-water spray, (e) cleaned with 70% ethanol, (f) cleaned with Ivoclean, or (g) cleaned with nonthermal atmospheric plasma (NTAP). The wettability and microbial decontamination of the surfaces were determined after saliva contamination or cleaning. Monobond Plus (Ivoclar Vivadent) was applied after cleaning, followed by Variolink LC (Ivoclar Vivadent). The samples were stored 1 week before shear bond strength (SBS) testing, and data (SBS and wettability) were analyzed by one-way analysis of variance and Tukey test (α = .05).
RESULTS: Saliva contamination reduced SBS to zirconia compared to not contaminated. Both Ivoclean and NTAP produced higher SBS compared to not cleaned and were not significantly different from the not contaminated. Ivoclean produced the highest contact angle, and NTAP the lowest. With the exception of using just water-spray, all cleaning protocols decontaminated the specimens.
CONCLUSIONS: Both Ivoclean and NTAP overcame the effects of saliva contamination, producing an SBS to zirconia comparable to the positive control. CLINICAL SIGNIFICANCE: Dental ceramics should be cleaned prior to resin cementation to eliminate the effects of human saliva contamination, and Ivoclean and NTAP are considered suitable materials for this purpose.
© 2020 Wiley Periodicals LLC.

Entities:  

Keywords:  decontamination; dental ceramics; nonthermal atmospheric plasma; resin cement; shear bond strength

Mesh:

Substances:

Year:  2020        PMID: 32598095     DOI: 10.1111/jerd.12615

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  4 in total

1.  Cytotoxicity and Bonding Property of Bioinspired Nacre-like Ceramic-Polymer Composites.

Authors:  Hui Sun; Kefeng Gao; Zhe Yi; Chengwei Han; Zengqian Liu; Qiang Wang; Qing Zhou; Zhefeng Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-05-23

2.  10-Methacryloyloxydecyl Dihydrogen Phosphate (10-MDP)-Containing Cleaner Improves Bond Strength to Contaminated Monolithic Zirconia: An In-Vitro Study.

Authors:  Mohamed M Awad; Feras Alhalabi; Khaled Mosfer Alzahrani; Majed Almutiri; Fawaz Alqanawi; Lafi Albdiri; Abdullah Alshehri; Ali Alrahlah; Mohammed H Ahmed
Journal:  Materials (Basel)       Date:  2022-01-28       Impact factor: 3.748

3.  Effect of Different Cleaning Methods on Shear Bond Strength of Resin Cement to Contaminated Zirconia.

Authors:  Maher Saeed Hajjaj; Saeed Jamaan Alzahrani
Journal:  Materials (Basel)       Date:  2022-07-21       Impact factor: 3.748

4.  UV-Mediated Photofunctionalization of Indirect Restorative Materials Enhances Bonding to a Resin-Based Luting Agent.

Authors:  Kyoko Ishikawa; Monica Yamauti; Antonin Tichy; Masaomi Ikeda; Takeshi Ueno; Noriyuki Wakabayashi; Ornnicha Thanatvarakorn; Taweesak Prasansuttiporn; Celso Afonso Klein-Junior; Akifumi Takahashi; Tomohiro Takagaki; Masatoshi Nakajima; Junji Tagami; Keiichi Hosaka
Journal:  Biomed Res Int       Date:  2021-05-29       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.