Improved MR imaging of the brain by using compensating gradients to suppress motion-induced artifacts.

R M Quencer1, R S Hinks, P H Pattany, M Horen, M J Post.   

Abstract

Sixty patients were examined with and without extra gradient pulses, which compensate for motion-induced phase errors, in order to determine the effect those gradients had in suppressing the motion artifacts frequently present in the brainstem, temporal lobes, and basal ganglionic regions on routine T2-weighted brain MR imaging. Two comparative studies were performed: (1) in 50 patients the motion-artifact suppression technique (MAST) was compared with a single-echo MR examination, and (2) in 10 patients the MAST technique was compared with the second echo of a symmetric dual-echo sequence. In the first study 39 patients were examined at 1.5 T and 11 patients were examined at 0.5 T with the same pulse sequences. We found that MAST resulted in a significant improvement of image quality in 24 of 39 patients on the high-field-strength system and in two of 11 patients on the mid-field-strength system. In the second study, we found that in four of the 10 patients, MAST resulted in a suppression of artifacts greater than that achieved by even-echo rephasing alone. With MAST, artifacts were eliminated that not only obscured normal structures but that could have left doubt about the presence of a true signal abnormality. There was, however, marked suppression of the CSF flow-void phenomenon and increased signal from flowing blood, particularly in the cortical veins and dural sinuses. Because of this, the use of additional pulse sequences in which these motion-compensating gradients were not used was necessary under certain clinical circumstances. We conclude that, with these motion-compensating gradients, artifacts are reduced or eliminated, and a marked improvement in image quality can be obtained without the need for cardiac gating.

Entities:  

Mesh:

Year:  1988        PMID: 3259801     DOI: 10.2214/ajr.151.1.163

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Cine MR in the evaluation of normal and abnormal CSF flow: intracranial and intraspinal studies.

Authors:  R M Quencer; M J Post; R S Hinks
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

2.  Clinical utility of partial flip angle T2-weighted spin-echo imaging of the brain.

Authors:  K H Chang; J G Yi; M H Han; M H Cho; M C Han; Z H Cho; C W Kim
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

3.  Signal Intensity within Cerebral Venous Sinuses on Synthetic MRI.

Authors:  Lydia Chougar; Akifumi Hagiwara; Nao Takano; Christina Andica; Julien Cohen-Adad; Marcel Warntjes; Tomoko Maekawa; Masaaki Hori; Saori Koshino; Misaki Nakazawa; Osamu Abe; Shigeki Aoki
Journal:  Magn Reson Med Sci       Date:  2019-04-05       Impact factor: 2.471

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.