Chia-Ju Yang1, Ding-Ping Chen2, Ying-Hao Wen3, Nan-Chang Lai1, Hsiao-Chen Ning4. 1. Department of Laboratory Medicine, Taiwan, Republic of China. 2. Department of Laboratory Medicine, Taiwan, Republic of China; Medical Biotechnology and Laboratory Science, Taiwan, Republic of China; Graduate Institute of Biomedical Sciences, Taiwan, Republic of China. 3. Department of Laboratory Medicine, Taiwan, Republic of China; Graduate Institute of Clinical Medical Sciences, Taiwan, Republic of China. 4. Medical Biotechnology and Laboratory Science, Taiwan, Republic of China; Department of Medical Research and Development, Chang Gung Memorial Hospital, Taoyuan, Taiwan, Republic of China. Electronic address: ning@cgmh.org.tw.
Abstract
BACKGROUND: Taiwan has the highest end-stage renal disease prevalence in the world, and the costs on the maintenance of dialysis imposes a great financial burden on National Health Insurance. Routine urinalysis provides an opportunity for the early detection of microalbuminuria. We evaluated the accuracy of semi-quantitative chemical methods from Siemens Novus Pro12 dipstick for albumin-creatinine ratio (ACR). METHODS: We collected 1029 random urine samples and performed urinary analytic tests by Siemens Novus with Pro12 dipsticks and also calculated the urinary ACR. The reference method was performed by Hitachi LST008, a quantitative assay. The percentage of exact agreement in ACR was 81.9% between Siemens Novus and Hitachi LST008. The percentage of agreement within 1 level between the 2 methods was 98.5%. When ACR > 30 mg/g was defined as the threshold for positive results, the sensitivity, specificity, positive, and negative predictive values for microalbuminuria were 87.2%, 91.6%, 91.5%, and 87.3%, respectively. There were 778 cases with negative results of urinary protein, analyzed by conventional dipsticks. 149 of 778 (19.2%) cases were positive, measured by Pro12 dipsticks, and 111 of 149 (74.5%) cases were confirmed positive ACR by Hitachi LST008. CONCLUSIONS: Urinary ACR measured by Siemens Novus with Pro12 dipsticks was shown to be a reliable test for detection of microalbuminuria.
BACKGROUND: Taiwan has the highest end-stage renal disease prevalence in the world, and the costs on the maintenance of dialysis imposes a great financial burden on National Health Insurance. Routine urinalysis provides an opportunity for the early detection of microalbuminuria. We evaluated the accuracy of semi-quantitative chemical methods from Siemens Novus Pro12 dipstick for albumin-creatinine ratio (ACR). METHODS: We collected 1029 random urine samples and performed urinary analytic tests by Siemens Novus with Pro12 dipsticks and also calculated the urinary ACR. The reference method was performed by Hitachi LST008, a quantitative assay. The percentage of exact agreement in ACR was 81.9% between Siemens Novus and Hitachi LST008. The percentage of agreement within 1 level between the 2 methods was 98.5%. When ACR > 30 mg/g was defined as the threshold for positive results, the sensitivity, specificity, positive, and negative predictive values for microalbuminuria were 87.2%, 91.6%, 91.5%, and 87.3%, respectively. There were 778 cases with negative results of urinary protein, analyzed by conventional dipsticks. 149 of 778 (19.2%) cases were positive, measured by Pro12 dipsticks, and 111 of 149 (74.5%) cases were confirmed positive ACR by Hitachi LST008. CONCLUSIONS: Urinary ACR measured by Siemens Novus with Pro12 dipsticks was shown to be a reliable test for detection of microalbuminuria.