Literature DB >> 32593195

Experience for use of modified full-face snorkel mask as personal protective equipment during endoscopic procedures in the era of coronavirus disease pandemic.

Chika Kusano1, James Goddard2, Takuji Gotoda1.   

Abstract

Entities:  

Mesh:

Year:  2020        PMID: 32593195      PMCID: PMC7361334          DOI: 10.1111/den.13784

Source DB:  PubMed          Journal:  Dig Endosc        ISSN: 0915-5635            Impact factor:   6.337


× No keyword cloud information.
The rapid spread of coronovirus disease 2019 (COVID‐19) has led to a personal protective equipment (PPE) shortage worldwide. , Recently, the adaptation of commercially available modified full‐faced snorkel masks (mFFSMs) has been proposed as an alternative in times of PPE shortage. The mFFSMs were adapted and used by health care workers during the COVID‐19 crisis. An mFFSM is composed of an off‐the‐shelf snorkel mask, a custom adapter (three‐dimensional‐printed with a custom print file that sourced attributes from the designs found at Pneumask and OceanReef), and a filter cartridge (Fig. 1a).
Figure 1

(a) Modified full‐face snorkel mask: snorkel mask (Easybreath Surface Snorkeling Mask; Decathlon) (black arrow), a custom adapter (red arrow), and a filter cartridge (HME Twin Star® MP0 1805; Dräger, Lübeck, Germany) (blue arrow). (b) Personal protective equipment with general facial protection. (c) Personal protective equipment with a modified full‐face snorkel mask.

(a) Modified full‐face snorkel mask: snorkel mask (Easybreath Surface Snorkeling Mask; Decathlon) (black arrow), a custom adapter (red arrow), and a filter cartridge (HME Twin Star® MP0 1805; Dräger, Lübeck, Germany) (blue arrow). (b) Personal protective equipment with general facial protection. (c) Personal protective equipment with a modified full‐face snorkel mask. Nine endoscopists performed endoscopic procedures using general facial protection (N95 mask, goggle, and face shield) (Fig. 1b) and mFFSM (Fig. 1c). The vital signs of the endoscopists were assessed before they wore the PPE and were re‐assessed after 30 min. All vital signs pre‐ and post‐endoscopic procedures are shown in Table 1. With a mFFSM, the respiratory rate increased significantly post‐endoscopy (P = 0.034).
Table 1

Comparison of the vital signs of the endoscopists using general facial protection vs. the modified full‐face snorkel mask

General facial protection P‐valueModified‐FFSM P‐value
Pre‐endoscopyPost‐endoscopyPre‐endoscopyPost‐endoscopy
Blood pressure
Systolic (mmHg)117.4 ± 18.2115.2 ± 15.50.889118.1 ± 16.7122.2 ± 12.90.313
Diastolic (mmHg)78.5 ± 14.177.8 ± 12.10.72179.3 ± 13.182.1 ± 9.80.313
Pulse rate (/min)72.2 ± 11.676.7 ± 15.20.10874.7 ± 13.078.7 ± 16.10.291
Oxygen saturation (%)98.5 ± 1.097.6 ± 0.80.05698.4 ± 1.097.6 ± 1.00.106
Respiratory rate (/min)15.5 ± 1.815.6 ± 2.60.79816.0 ± 3.517.5 ± 3.20.034
(Mean ± SD)

Categorical valuables were analyzed via the Wilcoxon signed‐rank test. Statistical significance was considered as P < 0.05. All analyses were conducted using R language and environment for statistical computing (version 3.5.2, R Core Team, 2018, R Foundation for Statistical Computing, Vienna, Austria).

Comparison of the vital signs of the endoscopists using general facial protection vs. the modified full‐face snorkel mask Categorical valuables were analyzed via the Wilcoxon signed‐rank test. Statistical significance was considered as P < 0.05. All analyses were conducted using R language and environment for statistical computing (version 3.5.2, R Core Team, 2018, R Foundation for Statistical Computing, Vienna, Austria). This is the first report of experience with using a mFFSM during endoscopic procedure. We estimated that the benefits of a snorkel mask are that it provided an integrated full‐face shield instead of masks, goggles, and shields and allowed a clear view; thus, this mask is an off‐label application. We can consider the use of mFFSM, when no alternative PPE is available. The fit‐test of the mFFSM has been reported. , The quantitative fit‐test measures the leaks at the wearer’s face, leaks concerning the connection after the filter, and leaks related to the exhaust valve. However, it was suggested that the rise in carbon dioxide (CO2) intake triggered an increase in minute ventilation and the respiratory rate, thereby maintaining the level of end‐tidal CO2 within the normal range. The mFFSM has the potential for use during endoscopic procedures when PPE is insufficient, it is necessary to consider the characteristics of mFFSMs concerning the possibility of CO2 accumulation.

Conflicts of interest

Author T.G. is a Deputy Editor‐in‐Chief of Digestive Endoscopy. Other authors declare no conflict of interests for this article.
  3 in total

1.  Critical Supply Shortages - The Need for Ventilators and Personal Protective Equipment during the Covid-19 Pandemic.

Authors:  Megan L Ranney; Valerie Griffeth; Ashish K Jha
Journal:  N Engl J Med       Date:  2020-03-25       Impact factor: 91.245

Review 2.  Personal protective equipment during the coronavirus disease (COVID) 2019 pandemic - a narrative review.

Authors:  T M Cook
Journal:  Anaesthesia       Date:  2020-04-28       Impact factor: 6.955

3.  Safety testing improvised COVID-19 personal protective equipment based on a modified full-face snorkel mask.

Authors:  P R Greig; C Carvalho; K El-Boghdadly; S Ramessur
Journal:  Anaesthesia       Date:  2020-04-19       Impact factor: 12.893

  3 in total
  2 in total

Review 1.  Overview of the User Experience for Snorkeling Mask Designs during the COVID-19 Pandemic.

Authors:  Jacopo Profili; Emilie L Dubois; Dimitrios Karakitsos; Lucas A Hof
Journal:  Healthcare (Basel)       Date:  2021-02-14

2.  Bronchoscopy in children with COVID-19: A case series.

Authors:  Pierre Goussard; Lizelle Van Wyk; Jonathan Burke; Annemie Malherbe; Francois Retief; Savvas Andronikou; Lunga Mfingwana; Dries Ruttens; Marieke Van der Zalm; Angela Dramowski; Aishah Da Costa; Helena Rabie
Journal:  Pediatr Pulmonol       Date:  2020-08-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.