| Literature DB >> 32585545 |
Suvrotoa Mitra1, Mukti Kant Nayak2, Agniva Majumdar3, Avisek Sinha1, Soumyadipta Chatterjee1, Alok Deb4, Mamta Chawla-Sarkar5, Shanta Dutta3.
Abstract
Timely identification of etiological agents of enteric infections is necessary to reduce the burden of infantile diarrheal mortality. Nucleic acid amplification-based detection methods offer a quick, reliable way for diagnosis of microbes in clinical specimens. This study was undertaken to evaluate an easy-to-use, cost-effective multiplex conventional reverse-transcription polymerase chain reaction (RT-PCR) assay developed at the Indian Council of Medical Research-National Institute of Cholera and Enteric Diseases virology laboratory to identify 4 common enteric viruses (rotavirus, norovirus, adenovirus, astrovirus) in stool samples from patients who were being evaluated for acute diarrhea. On comparison with a commercially available real-time PCR method, significant agreement in sensitivity and specificity was observed. Though the turnaround time for RT-PCR was 6-8 h compared to 5-6 h for real-time PCR, the real-time PCR has high test cost (approximately 28 USD/2000 INR) for Fast-Track Diagnostics kit-based quantitative RT-PCR versus 6 USD or 400 INR for conventional multiplex RT-PCR/sample. Thus, the conventional RT-PCR method is expected to be adaptable at local hospitals and health cares in resource-poor settings.Entities:
Keywords: Co-infections; Enteric viruses; Molecular diagnostics; Multiplex RT-PCR
Mesh:
Substances:
Year: 2020 PMID: 32585545 DOI: 10.1016/j.diagmicrobio.2020.115061
Source DB: PubMed Journal: Diagn Microbiol Infect Dis ISSN: 0732-8893 Impact factor: 2.803