| Literature DB >> 32582829 |
Farahnaz Sharafeddin1, Ali Asghar Alavi1, Saba Siabani2, Mina Safari2.
Abstract
STATEMENT OF THE PROBLEM: The clinical success of glass ionomer cement (GIC) restorations depends on the strength of its bonding to dentin, yet the bond strength of nanohydroxyapatite (nHAp) added GIC to dentin needs to be investigated.Entities:
Keywords: Glass ionomer cements; Hydroxyapatites; Nanoparticles; Shear strength
Year: 2020 PMID: 32582829 PMCID: PMC7280551 DOI: 10.30476/DENTJODS.2019.77762.0
Source DB: PubMed Journal: J Dent (Shiraz) ISSN: 2345-6418
Composition of the materials used in the study
| Material | Manufacturer | Composition |
|---|---|---|
| Fuji IX GP Extra TM | GC Corporation, Japan | Aluminosilicate glasses |
| Polyacrylic acid powder | ||
| Polybasic carboxylic acid | ||
| Fuji II LC | GC Corporation, Japan | Powder: Alumino-fluoro-silicate glass, Urethanedimethacrylate, Camphor Quinone |
| Liquid: Polymer acrylic acid, Distill water, 2-hydroxyethylmethacrylate (HEMA) | ||
| Zirconomer Improved | Shofu Inc., Japan | Powder: Alumino-fluoro-silicate glass, |
| Zirconium oxide, Tartaric acid | ||
| Liquid: Polyacrylic acid | ||
| Deionized water | ||
| Nano hydroxyapatite | Sigma-Aldrich, USA | Calcium hydroxyphosphate hydroxide, |
| Durapatite, Hydroxyapatite | ||
| Cavity conditioner | GC Corporation, Japan | Polyacrylic acid (20%), water, aluminum chloride hydrate |
| Varnish | Kimia , Iran | Copal, Ethanol |
Figure 1The specimen under the SBS test in the universal testing machine
Figure 2a: Adhesive failure (Fuji II LC+nHAp), no observable glass ionomer the dentin surface. b: Cohesive failure (Zirconomer Improved +nHAp), visible amounts of glass ionomer remained on the dentin surface. c: Mixed failure (Fuji II LC +nHAp), a mixture of both adhesive and cohesive failures
shear bond strength (MPa) median, mean values and standard deviation of experimental groups
| GIC Subgroups (n=10) | Superficial Dentin Median (mean±SD) | Deep Dentin Median (mean±SD) | p Value |
|---|---|---|---|
| Fuji IX Extra + nHAp | 6.24 (6.21±0.72)A | 4.06 (4.07±0.66)A | <0.0001 |
| Fuji II LC + nHAp | 10.75 (10.38±2.81)B | 9.11 (9.16±1.51)B | <0.481 |
| Zirconomer Improved + nHAp | 6.24 (6.25±0.65)A | 5.53 (5.35±0.70)A | <0.009 |
|
| <0.0001 | <0.0001 | |
Kruskal-wallis H test
Mann-Whitney U test
In each column median values with different capital letters were statistically significant (Dunn test)
Figure 3Shear bond strength of material at superficial and deep dentin groups
Figure 4Frequency of fracture modes of three types of GIC + nHAp at superficial (left) and deep (right) dentin groups