| Literature DB >> 32580455 |
Jianwu Chen1,2, Longzhe Jin1, Zhenfang Chen2, Bin Yang2, Yanqiu Sun2, Shulin Zhou2.
Abstract
A parallel-flow exhaust hood is an effective ventilation device to control dust and toxic pollutants and protect the occupational health of workers, whether it is used alone or combined with a uniform air supply hood in a push-pull ventilation system. Some scholars have studied the outside air flow characteristics of the conventional exhaust hood with non-uniform air speed at the hood face, but the law of velocity variation outside the parallel-flow exhaust hood is not clear at present. Therefore, this paper uses the dimensionless method to study the center-line velocity change regime in a parallel-flow square exhaust hood based on simulation and experimental data. The results show that the dimensionless center-line velocity has a good change law with the characteristic length of exhaust hood in a parallel-flow square exhaust hood, which can eliminate the influence of hood face velocity and the hood size on the velocity change regime; and the experimental data is basically consistent with the calculated data, which shows that the regression equation method is reliable.Entities:
Keywords: center-line velocity; exhaust hood; parallel-flow; poison control
Year: 2020 PMID: 32580455 DOI: 10.3390/ijerph17124485
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390