Quantitative Near-Infrared Imaging of Platelets in Platelet-Rich Fibrin (PRF) Matrices: Comparative Analysis of Bio-PRF, Leukocyte-Rich PRF, Advanced-PRF and Concentrated Growth Factors.

Hachidai Aizawa1, Tetsuhiro Tsujino1, Taisuke Watanabe1, Kazushige Isobe1, Yutaka Kitamura1, Atsushi Sato1, Sadahiro Yamaguchi1, Hajime Okudera1, Kazuhiro Okuda2, Tomoyuki Kawase3.   

Abstract

Platelet-rich fibrin (PRF) is a fibrin matrix enriched with platelets. The PRF matrix is thought to form a steep gradient of platelet density around the region corresponding to the buffy coat in anticoagulated blood samples. However, this phenomenon has not yet been proven. To visualize platelet distribution in PRF in a non-invasive manner, we utilized near-infrared (NIR) imaging technology. In this study, four types of PRF matrices, bio-PRF, advanced-PRF (A-PRF), leukocyte-rich PRF (L-PRF), and concentrated growth factors (CGF) were compared. Blood samples collected from healthy, non-smoking volunteers were immediately centrifuged using four different protocols in glass tubes. The fixed PRF matrices were sagittally divided into two equal parts, and subjected to modified immunohistochemical examination. After probing with NIR dye-conjugated secondary antibody, the CD41+ platelets were visualized using an NIR imager. In L-PRF and CGF, platelets were distributed mainly on and below the distal surface, while in bio-PRF and A-PRF, platelet distribution was widespread and homogenous. Among three regions of the PRF matrices (upper, middle, and lower), no significant differences were observed. These findings suggest that platelets aggregate on polymerizing fibrin fibers and float up as a PRF matrix into the plasma fraction, amending the current "gradient" theory of platelet distribution.

Entities:  

Keywords:  distribution; near-infrared imaging; platelet-rich fibrin; platelets

Mesh:

Substances:

Year:  2020        PMID: 32580336      PMCID: PMC7352590          DOI: 10.3390/ijms21124426

Source DB:  PubMed          Journal:  Int J Mol Sci        ISSN: 1422-0067            Impact factor:   5.923


1. Introduction

Platelet-rich fibrin (PRF), as its name implies, is a fibrin matrix enriched with platelets and their growth factors [1]. This characteristic constitution has led PRF to be widely used in regenerative medicine. However, the concentration and distribution of platelets remain unclear. Platelet counts are commonly evaluated using the “subtraction” method [2], which directly determines platelet counts in soluble fractions, e.g., PRF exudate fraction, and indirectly evaluates platelet counts in insoluble PRF matrices. In 2018, we developed a novel method that directly determines platelet counts via digestion using tissue plasminogen activator and demonstrated its validity and accuracy in comparison with those of the subtraction method [3]. To date, micrographic examination methods using scanning electron microscopy (SEM) and immunohistochemical techniques have been the only practical options for evaluating platelet distribution [4,5,6,7]. However, the data obtained using these methods are often too fragmented to adequately evaluate platelet distribution in three-dimensional (3D) structures by reconstruction. In recent years, efforts to modify the original Chouroun’s method for leukocyte and platelet-rich fibrin (L-PRF) [8] have led to the development of several PRF derivatives, including concentrated growth factors (CGF) [9] and advanced-PRF (A-PRF) [6]. More recently, this has led to the development of another PRF derivative, bio-PRF [10]. According to our understanding, the main goals of these modifications have been to: (1) form mechanically tough fibrin matrices using thicker and well-crosslinked fibrin fibers; (2) improve the capacity for growth factor retention and release; (3) exclude (or include) more leukocytes. To this end, various centrifugal forces (speed) and time frames have been trialed. Furthermore, the types of centrifuges and blood collection tubes have also been optimized. However, the commercial interests of most vendors of equipment dictate branding their own special products, including centrifuges and related supplies, to beat their competitors. As a result, equipment produced by different brands is not often found in one laboratory, which in turn hinders the ability for the comparative analysis or characterization of individual PRF derivatives from a biomedical point of view. Regardless of the protocol used, all PRF derivatives are thought to fractionate platelets in a similar manner depending on the specific gravity of the matrix. However, there is a lack of convincing evidence for this phenomenon. In a previous study [11], we used near-infrared (NIR) imaging technology to visualize the platelets in a PRF matrix. NIR rays (with a wavelength of approximately 750 to 2500 nm; wavelengths between 750 to 900 nm are used for clinical imaging) are highly transmittable in living organisms and are often used in animal experiments for non-invasive observation and in surgical navigation systems in clinical settings. Using NIR, we optimized the procedure of antibody probing and washing and successfully visualized platelet distribution [11]. Despite using the same centrifugation protocol, the platelet distribution of a CGF matrix prepared in glass tubes was found to be visibly distinguishable from that of a CGF matrix prepared in silica-coated plastic tubes. Interestingly, the distribution of platelets did not depend on their specific gravity in the CGF matrix. However, it is worth mentioning that previous SEM examinations of the surface of CGF (PRF) matrices have demonstrated a steep gravity-dependent gradation [7]. However, this may be due to the limitation of this visualization modality. In fact, in a previous study using immunohistochemical examination [12], platelets were found to also be present in the upper regions of a CGF matrix prepared using a programmed fast-spin protocol. In this study, we quantitatively and qualitatively re-evaluated the distribution of platelets in different PRF matrices using a non-invasive NIR imaging method and comparatively analyzed four types of PRF matrices.

2. Results

The platelet distributions visualized by NIR imaging are shown in Figure 1. Two separate pieces of PRF matrices were placed side-by-side (isotype control image (left) and CD41+ image (right)). In the bio-PRF matrix, the platelets were symmetrically distributed mainly in the peripheral regions along the long axis. In the CGF and the L-PRF matrices, the platelets were found to be accumulated mainly in the distal peripheral regions. In contrast, in the A-PRF matrix prepared by slow spin, the platelets were distributed nearly homogeneously.
Figure 1

NIR images of compressed half PRF matrices: (a) bio-PRF (horizontal, fast spin); (b) Concentrated growth factors (CGF) (fixed angle, fast programmed spin); (c) A-PRF (fixed angle, slow spin); (d) L-PRF (fixed angle, fast spin). White arrows represent platelet localization. An asterisk denotes homogeneous platelet distribution.

The quantitative determination of the fluorescence intensity of the individual PRF matrices is shown in Figure 2a. These fluorescence intensities represent the total counts of non-activated and activated platelets. The A-PRF matrix was found to contain the highest number of platelets.
Figure 2

(a) Specific fluorescence intensities of individual half platelet-rich fibrin (PRF) matrices. The data are expressed as the CD41+-isotype control ratio. n = 12. (b) The lengths of individual PRF matrices. n = 12.

The apparent lengths of the individual PRF matrices are shown in Figure 2b. As the shape of the bio-PRF matrix was different from those of the other matrices, its length could not be used for comparison. However, among the PRF matrices prepared using fixed angle rotors, the A-PRF matrix prepared by slow spin was found to be shorter than the L-PRF and CGF matrices. A comparison of the fluorescence intensities of the three regions (upper, middle, and lower) is provided in Figure 3. In the bio-PRF matrix, no significant differences were observed among these regions, and similar observations were made for both the A-PRF and L-PRF matrices.
Figure 3

Fluorescence intensities of three regions (upper, middle, and lower) of individual PRF matrices: (a) bio-PRF (horizontal, fast spin); (b) A-PRF (fixed angle, slow spin); (c) L-PRF (fixed angle, fast spin). No significant differences were found among these regions. n = 12.

To confirm the validity of the imaging data, we examined the platelet distribution using conventional immunohistochemical methods using paraffin sections. The representative platelet distributions in the three regions of the A-PRF and CGF matrices are shown in Figure 4. As observed through NIR imaging, the platelets appeared to be distributed nearly homogeneously in the A-PRF matrix prepared by slow spin. In the CGF matrix, in contrast, the platelets appeared to be localized mainly in the distal peripheral regions of all three regions. In addition, in both matrices, the platelets could also be detected in the upper region as observed in the other two regions.
Figure 4

Representative photomicrographs of conventional immunohistochemically-stained sections showing platelet distribution in A-PRF prepared by slow spin (a) and CGF prepared by fast spin. (b) Brown particles represent platelets. Scale bar, 200 μm.

3. Discussion

3.1. Advantages and Limitations of Our Imaging Method

As described in our previous study [11], although our imaging method was not capable of quantitatively examining the 3D structure of the PRF matrix, the main advantage of using the compressed PRF membrane was the quantitative and qualitative evaluation of platelet distribution without the need for destruction or sectioning. Although the non-specific binding of the antibodies may raise concerns, we overcame this shortcoming by making several technical modifications, including interrupted gentle mixing during fixation, prolonged incubations in PBS and blocking solution, short-term incubations with secondary antibody, and extensive washings using a vortex mixer at each interval. Furthermore, the samples were divided into two equal parts, one part for specific binding and the other for non-specific binding, to calculate the signal-to-noise (S/N) ratio. This modification resulted in a remarkable improvement in specificity. With regards to other shortcomings, the NIR imager was originally designed for animal observation. As such, its resolution (85 μm) was not high enough to observe individual platelets (ϕ1–3 μm). However, since the length of the whole PRF matrix, when compressed, was 25–40 mm, it was slightly too large to observe without image pasting using conventional microscopes. Moreover, it is difficult to evaluate the fluorescence intensity of a subject by image analysis using fluorescence images comprised of photos pasted together without significant distortion. Thus, we accepted the trade-off between the resolution and the one-shot observation.

3.2. How Are Platelets Distributed in PRF Matrices?

To date, it remains generally accepted that the distribution of platelets in insoluble PRF matrices depends on their specific gravity, as observed in liquid platelet-rich plasma (PRP) preparations. However, this is inconsistent with the data. If the number of platelets in PRF matrices was similar to that in single-spin-prepared PRP preparations, it would account for roughly 40–70% of the total platelet counts in whole-blood samples. However, several studies have reported that over 90% of platelets are included in PRF matrices by the subtraction method [2,13,14,15]. The main finding of the present study is that platelet distribution in PRF matrices is not gravity-dependent. In the case of centrifuges equipped with fixed angle rotors, the platelet distribution was found to be mainly influenced by the level and direction of the centrifugal force and the distance from the glass surface but not by the angulation level. When centrifuged by slow spin, the platelets were distributed homogeneously. When centrifuged by fast spin, the platelets were distributed on and below the surface, facing the distal inner wall of glass tubes, i.e., that which had received the centrifugal force. In addition, the programmed changes in centrifugal speed did not appear to substantially alter the platelet distribution. On the contrary, in the case of horizontal centrifuges equipped with swing rotors, the platelets were distributed almost homogenously, even at relatively fast centrifugation speeds.

3.3. What Does the Difference in Platelet Distribution Imply?

During coagulation, the majority of platelets aggregate on fibrin fibers during the process of fibrin formation. As illustrated in Figure 5, the platelets entrapped within gradually coagulating fibrin clots are then fractionated by the specific gravity of the fibrin clot‒platelet complexes, rather than by the platelets alone. Furthermore, fibrin polymerization is triggered by the contact between coagulation factor XII and the glass surface [16]. Due to the activation of platelets on the glass surface, especially on the distal side of the inner wall, fibrin formation is asymmetrical, according to the centrifugal force. Therefore, it is plausible that platelets can be accumulated synergistically by centrifugal force and simultaneous coagulation on the distal side, in the case of the fast spin.
Figure 5

Schematic representation of PRF formation during centrifugation and the resulting platelet accumulation in specific regions of PRF matrices. (a) According to the conventional and widely-accepted concept, specific gravity-dependent fractionation precedes coagulation almost homogenously. Thus, the gradation of platelet density is preserved in PRF matrices. (b) In our proposed concept, coagulation occurs from the outside, a little earlier than fractionation. Thus, platelets entrapped loosely in gradually clotting PRF matrices are accumulated in the distal peripheral region. This proposed mechanism is consistent with our observations.

By contrast, the conventional and widely-accepted notion of PRF formation states that platelets are initially fractionated along with other blood cells depending on their specific gravities. Subsequently, coagulation leads to the entrapment of platelets. Therefore, in this case, platelets must accumulate on the interface between the RBC fraction and the PRF matrix, which corresponds to the “buffy coat” in the PRP preparation. Our findings do not support this concept.

3.4. What Does the Platelet Distribution Influence?

In several previous studies [3,7,17,18], we have developed techniques and standards to ensure the quality of PRP and PRF during their preparation. If carried out aseptically, as designed, the remaining criteria for quality assurance during the preparation of the matrices include the efficacy and potency of PRF matrices in clinical applications. Since growth factors are served by platelets upon activation and because thrombin and other coagulation factors are also stored by platelets, to guarantee the quality of each preparation and predict each resulting clinical outcome, platelet quantity and quality must be evaluated. In a previous study [19], we observed that major growth factors (e.g., TGFβ1, PDGF-BB, and VEGF) accumulate on and below the surface of CGF matrices, facing the proximal side of the inner wall, that is, the opposite side of platelet accumulation. These findings suggest that both platelets, which retain growth factors unless fully activated, and the released growth factors are localized to the surface and peripheral regions of the matrices. Thus, the fact that fibrin fibers are digested from the surface regions of implantation sites implies that growth factors are released within relatively short periods of time. The capacity of this release is too low to continuously influence the surrounding tissues and cells. To evaluate the distribution of growth factors, direct imaging of growth factors was used to obtain more convincing data. In the case of platelet detection, imaging methods require monoclonal antibodies with a high specificity and affinity; however, we have not yet found the appropriate antibodies for the growth factors or other major components. Currently, this represents an additional limitation of this method.

3.5. Clinical Relevance of These Findings

To improve the quality of PRF matrices, it is important to establish standardized preparation protocols. However, even during the preparation of PRF matrices, which are less affected by the skills of the operators, biases can arise due to practical constraints and individual donors. Therefore, these need to be minimized. For example, although silica-coated plastic tubes can be used to prepare macroscopically similar PRF matrices as glass tubes, the former PRF matrices are distinguishable from the latter in terms of platelet distribution and contamination with health-hazardous silica microparticles [20,21]. Thus, we propose the necessity for the “inspection of all products.” In other words, advanced cell-medicinal products should all be inspected prior to their clinical application. By contrast, in the case of PRF matrices, which can be prepared aseptically and quickly, inspection is performed to evaluate the components that influence their potency, rather than for the identification of negative criteria that may pose health hazards. As such, inspection may be performed prior to clinical use or the inspection data may be obtained after clinical use. The data can be useful for randomized clinical trials and subsequent meta-analyses to establish evidence-based medication for platelet concentrates. To date, we have developed several methods for the quality assurance of PRF preparation. The platelet quantity and level of aggregation activity can be tested at the point of care, only requiring short periods of time. In contrast, NIR imaging, such as immunological detection, requires at least two days. However, this is almost as long as the time for paraffin section-based immunohistochemical examination. Thus, regardless of the protocols and devices used for PRF preparation, we expect NIR imaging to provide a potent strategy for evaluating the quality of PRF matrices in the near future.

4. Materials and Methods

4.1. Preparation of PRF Matrices

Blood samples were collected from six healthy, non-smoking male and female volunteers aged 31 to 71 years. Depending on the purpose of each experiment, the minimum essential number of donors was randomly selected for sample collection. In the experiments using a CGF matrix prepared from whole-blood samples, blood samples were collected on two occasions at one-week intervals. The number of samples used is indicated in the legend corresponding to each figure. The study design and consent forms for all procedures performed (project identification code: 2297) were approved by the Ethics Committee for Human Participants of Niigata University School of Medicine (Niigata, Japan) in accordance with the Helsinki Declaration of 1964 (as revised in 2013). As described previously [11], blood (~9 mL) was collected from the volunteers in plastic vacuum plain blood collection tubes (Neotube #NP-PN0909; Nipro, Osaka, Japan) by peripheral venipuncture in one of the antecubital fossa veins. The blood samples were then transferred to plain glass tubes (Nichiden-Rika Glass Co Ltd., Kobe, Japan) and immediately centrifuged under the recommended centrifugal conditions using four types of centrifuges, one horizontal centrifuge (#5702; Eppendorf, Hamburg, Germany) and three fixed angle centrifuges [Medifuge (Silfradent S. r. l., Santa Sofia, Italy), Duo Quattro (Process for PRF, Nice, France), and EBA200 (Hettich, Vlotho, Germany)] (Figure 6a) (Table 1). Depending on the protocols of the individual centrifuges, distinguishable PRF matrices were formed (Figure 6b).
Figure 6

(a) Centrifuges used in this study. (b) The appearance of the corresponding PRF matrices in glass tubes after centrifugation.

Table 1

Devices and centrifugal conditions for preparation of individual PRF matrices.

TitleBio-PRFCGFA-PRFL-PRF
Vacuum tubes (manufacturer)Plain plastic tube (Nipro)Plain plastic tube (Nipro)Plain plastic tube (Nipro)Plain plastic tube (Nipro)
2nd tubes (manufacturer)Plain glass tube (Nichiden-Rika Glass)Plain glass tube (Nichiden-Rika Glass)Plain glass tube (Nichiden-Rika Glass)Plain glass tube (Nichiden-Rika Glass)
Centrifuges (manufacture)#5702 (Eppendorf)Medifuge (Silfradent) Duo Quattro (Process for PRF)EBA200 (Hettich)
Rotor typesSwingAngleAngleAngle
Rotor angulationHorizontal33°41.3°33°
Centrifugal force (time)700× g (8 min)692× g (2 min) 547× g (4 min) 592× g (4 min) 885× g (3 min)200× g (14 min*)400× g (12 min)
A fraction of red blood cells (RBC) (e.g., clot) was cut off using scissors. Then, the PRF matrices were gently washed with phosphate buffered saline (PBS) and fixed in 10% neutralized formalin (FUJIFILM Wako Pure Chemical Corp., Osaka, Japan) for 3–5 h in plastic tubes to prevent the collapse of the original PRF matrix shape. Thereafter, the PRF matrices were transferred to PBS and stored at 4 ℃ until use, usually within 24 h. To record the basic characteristics of individual blood samples, the number of platelets and other blood cells in the whole-blood samples and PRP preparations was determined using an automated hematology analyzer (pocH 100iV; Sysmex, Kobe, Japan). Although several protocols called for specific tubes (e.g., silicone-coated glass tubes or silica-coated plastic tubes), the blood samples were initially collected in plain plastic tubes, then transferred into plain glass tubes within a short period of time (~2 min) [11]. It should be noted that the main purpose of this procedure was to minimize variations in the results due to tube type, as well as highlight the effects of centrifugal conditions. For example, silicone used to coat the inner surface of glass tubes impedes contact between coagulation factor XII in the blood and the silanol residue on the glass surface to delay coagulation. On the contrary, silica-coated tubes facilitate coagulation before centrifugation, such that much of the red blood cell fraction is clotted, resulting in smaller PRF clots.

4.2. NIR Imaging of Platelet Distribution in PRF Matrices

The fixed PRF matrices were sagittally divided into two equal pieces (Figure 7). The 3D structure of the bio-PRF matrix was cylindrical; thus, its top view was very similar to its side view. After fixation, the PRF matrix was sagittally divided into two, almost equal pieces along randomly chosen lines. The 3D structures of the A-PRF, L-PRF, and CGF matrices were also cylindrical, but they were distorted against the long axis. Thus, in the side view, their shape was a parallelogram. The PRF matrices were divided along the central axis of their top view.
Figure 7

The differences in the shapes of individual platelet-rich fibrin (PRF) matrices. The shape of bio-PRF (a) is distinguishable from those of other PRF matrices (b). The “cutting line” represents the center line of PRF matrices for the sagittal section.

Of the two PRF pieces, one was used for the detection of CD41+ platelets, while the other was used as an isotype control [11]. The PRF pieces were dehydrated using KimWipes (Kimberly-Clark Corp., Dallas, TX, USA) and washed twice in PBS containing 0.1% Tween 20 (0.1T-PBS) in six-well plates for 10 min using a vortex mixer. After dehydration, the PRF pieces were blocked for 24 h in 2% Block Ace (Sumitomo Dainippon Pharma, Osaka, Japan) solution dissolved in 0.1 T-PBS (BA-TPBS) in 2-mL sample tubes at 4 °C. The PRF pieces were then dehydrated, washed twice (as described above), and probed with mouse monoclonal human CD41 antibody (BioLegend, San Diego, CA, USA) at a 3:1000 dilution for 24 h at 4 °C. The PRF isotype controls were treated with non-immunized mouse IgG (BioLegend). After primary antibody treatment, the PRF pieces were dehydrated, washed in 0.1 T-PBS using a vortex mixer, and probed with NIR dye-conjugated goat anti-mouse IgG (1:4500) (iFluor 790; AAT Bioquest, Inc., Sunnyvale, CA, USA) for 90 min at 4 °C. The PRF pieces were then washed using a vortex mixer, dehydrated using KimWipes, and scanned at 800 nm using a Pearl NIR imaging system (Li-Cor, Lincoln, NE, USA). The dye was excited using an 800 nm channel laser source (solid-state laser diode at 785 nm). An emission at 820 nm was detected using a cooled CCD detector. The total florescence intensity of each half of the PRF membrane was measured using software provided by Li-Cor. The fluorescence intensity of the background was subtracted from that of the matrix. The fluorescence intensity of the CD41 antibody-reactive proteins was expressed as the ratio of the fluorescence intensity of CD41 to that of the corresponding isotype control. Strong correlations between fluorescence intensity and fluorescence dye concentration or suspended platelet count were reported in our previous study, where approximately 80% of near-infrared light (800 nm) was transmitted through a compressed dehydrated PRF membrane [11].

4.3. Immunohistochemical Examination

Freshly prepared PRF matrices were gently, but not fully, compressed using a stainless-steel PRF compression device (PRF stamper; JMR Corp. Ltd., Niigata, Japan); then, they were fixed, divided into seven pieces, dehydrated in a series of ethanol washes, embedded in paraffin, and sectioned for immunohistochemical examination using rabbit polyclonal anti-CD41 antibody (GeneTex, Irvine, CA, USA), horseradish peroxidase-conjugated goat anti-rabbit IgG antibody (Cell Signaling Technology, Danvers, MA, USA), and 3,3′-diaminobenzidine (DAB) substrate solution (Kirkegaard & Perry Laboratories, Inc., Gaithersburg, MD, USA) [7,12].

4.4. Statistical Analysis

The data are presented as box plots (Figure 2) and expressed as the mean ± standard deviation (Figure 3). For the fluorescence intensity data in Figure 2a, SigmaPlot (SigmaPlot 13.0; Systat Software, Inc., San Jose, CA, USA) was used to evaluate the image analysis data as being parametric by both normality (Shapiro–Wilk) and equal variance testing. One-way analysis of variance (ANOVA) was followed by Bonferroni’s multiple-comparisons test. For the length data in Figure 2b, the normality test failed. As such, a non-parametric Kruskal–Wallis one-way ANOVA on ranks was performed. All pairwise multiple comparisons were tested using Tukey’s test. For the comparison of the three parts in Figure 3, a non-parametric Kruskal–Wallis one-way ANOVA on ranks was performed, but no subsequent multiple-comparisons tests were performed. p < 0.05 was considered statistically significant.

5. Conclusions

In PRF matrices, platelet distribution depends to a great extent on the centrifugal force and type of rotor used, rather than on the specific gravity of the platelets. In this study, a buffy coat-like fraction did not form on the interface between the RBC fraction and the plasma/PRF fraction. When an angle rotor was used, an increased centrifugal speed was found to alter the distribution of platelets, changing from a widespread, homogenous distribution to an accumulation of platelets on and below the distal surface of the PRF matrices. However, various types of blood collection tubes are used in clinical settings. Compared with glass tubes, silica-coated plastic tubes facilitate coagulation and distribute platelets widely and homogenously in the resulting PRF matrices, regardless of the centrifugal speed used [12], while silicone-coated glass tubes delay coagulation, an effect which is expected to modify platelet distribution by interfering with the contact of coagulation factor XII with the glass surface. Thus, we should be careful with the devices used.
  20 in total

1.  Glass surface and blood coagulation.

Authors:  J MARGOLIS
Journal:  Nature       Date:  1956-10-13       Impact factor: 49.962

2.  Three-dimensional architecture and cell composition of a Choukroun's platelet-rich fibrin clot and membrane.

Authors:  David M Dohan Ehrenfest; Marco Del Corso; Antoine Diss; Jaafar Mouhyi; Jean-Baptiste Charrier
Journal:  J Periodontol       Date:  2010-04       Impact factor: 6.993

Review 3.  Platelet-rich plasma and its derivatives as promising bioactive materials for regenerative medicine: basic principles and concepts underlying recent advances.

Authors:  Tomoyuki Kawase
Journal:  Odontology       Date:  2015-06-04       Impact factor: 2.634

4.  A proposed protocol for the standardized preparation of PRF membranes for clinical use.

Authors:  Mito Kobayashi; Tomoyuki Kawase; Makoto Horimizu; Kazuhiro Okuda; Larry F Wolff; Hiromasa Yoshie
Journal:  Biologicals       Date:  2012-07-28       Impact factor: 1.856

5.  Advanced platelet-rich fibrin: a new concept for cell-based tissue engineering by means of inflammatory cells.

Authors:  Shahram Ghanaati; Patrick Booms; Anna Orlowska; Alica Kubesch; Jonas Lorenz; Jim Rutkowski; Constantin Landes; Robert Sader; Cj Kirkpatrick; Joseph Choukroun
Journal:  J Oral Implantol       Date:  2014-12       Impact factor: 1.779

6.  Striking Differences in Platelet Distribution between Advanced-Platelet-Rich Fibrin and Concentrated Growth Factors: Effects of Silica-Containing Plastic Tubes.

Authors:  Tetsuhiro Tsujino; Hideo Masuki; Masayuki Nakamura; Kazushige Isobe; Hideo Kawabata; Hachidai Aizawa; Taisuke Watanabe; Yutaka Kitamura; Hajime Okudera; Kazuhiro Okuda; Koh Nakata; Tomoyuki Kawase
Journal:  J Funct Biomater       Date:  2019-09-17

7.  A novel method for harvesting concentrated platelet-rich fibrin (C-PRF) with a 10-fold increase in platelet and leukocyte yields.

Authors:  Richard J Miron; Jihua Chai; Peng Zhang; Yuqing Li; Yunxiao Wang; Carlos Fernando de Almeida Barros Mourão; Anton Sculean; Masako Fujioka Kobayashi; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2019-12-02       Impact factor: 3.573

8.  Acute cytotoxic effects of silica microparticles used for coating of plastic blood-collection tubes on human periosteal cells.

Authors:  Hideo Masuki; Kazushige Isobe; Hideo Kawabata; Tetsuhiro Tsujino; Sadahiro Yamaguchi; Taisuke Watanabe; Atsushi Sato; Hachidai Aizawa; Carlos Fernando Mourão; Tomoyuki Kawase
Journal:  Odontology       Date:  2020-01-30       Impact factor: 2.634

9.  Evidence for Contamination of Silica Microparticles in Advanced Platelet-Rich Fibrin Matrices Prepared Using Silica-Coated Plastic Tubes.

Authors:  Tetsuhiro Tsujino; Akira Takahashi; Sadahiro Yamaguchi; Taisuke Watanabe; Kazushige Isobe; Yutaka Kitamura; Takaaki Tanaka; Koh Nakata; Tomoyuki Kawase
Journal:  Biomedicines       Date:  2019-06-19

10.  Spectrophotometric Determination of the Aggregation Activity of Platelets in Platelet-Rich Plasma for Better Quality Control.

Authors:  Tetsuhiro Tsujino; Kazushige Isobe; Hideo Kawabata; Hachidai Aizawa; Sadahiro Yamaguchi; Yutaka Kitamura; Hideo Masuki; Taisuke Watanabe; Hajime Okudera; Koh Nakata; Tomoyuki Kawase
Journal:  Dent J (Basel)       Date:  2019-06-03
View more
  9 in total

1.  Liquid Platelet-Rich Fibrin and Heat-Coagulated Albumin Gel: Bioassays for TGF-β Activity.

Authors:  Zahra Kargarpour; Jila Nasirzade; Layla Panahipour; Richard J Miron; Reinhard Gruber
Journal:  Materials (Basel)       Date:  2020-08-06       Impact factor: 3.748

2.  Purification of anti-glycoconjugate monoclonal antibodies using newly developed porous zirconia particles.

Authors:  Tetsuya Okuda; Katsuya Kato; Masahiro Kitamura; Shinjiro Kasahara
Journal:  Sci Rep       Date:  2021-02-09       Impact factor: 4.379

3.  Histological and Histomorphometric Evaluation of Applying a Bioactive Advanced Platelet-Rich Fibrin to a Perforated Schneiderian Membrane in a Maxillary Sinus Elevation Model.

Authors:  Liangjing Xin; Shuai Yuan; Zhixiang Mu; Dize Li; Jinlin Song; Tao Chen
Journal:  Front Bioeng Biotechnol       Date:  2020-11-26

4.  Lyophilised Platelet-Rich Fibrin: Physical and Biological Characterisation.

Authors:  Nurul Aida Ngah; George J Dias; Darryl C Tong; Siti Noor Fazliah Mohd Noor; Jithendra Ratnayake; Paul R Cooper; Haizal Mohd Hussaini
Journal:  Molecules       Date:  2021-11-25       Impact factor: 4.411

5.  Effects of autologous concentrated growth factor on gingival thickness in periodontal accelerated osteogenic orthodontics: a 6-month randomized controlled trial.

Authors:  Lei Qi; Weiwen Ge; Ningning Cao; Shoupeng Wang; Yifeng Qian; Xudong Wang; Lei Zhang
Journal:  BMC Oral Health       Date:  2021-11-23       Impact factor: 2.757

6.  A Strategic and Worldwide Cooperative Challenge Required for the Next Generation of Platelet Concentrates.

Authors:  Tomoyuki Kawase
Journal:  Int J Mol Sci       Date:  2022-03-22       Impact factor: 5.923

7.  Tensile Strength Essay Comparing Three Different Platelet-Rich Fibrin Membranes (L-PRF, A-PRF, and A-PRF+): A Mechanical and Structural In Vitro Evaluation.

Authors:  Mara Simões-Pedro; Pedro Maria B P S Tróia; Nuno Bernardo Malta Dos Santos; António M G Completo; Rogerio Moraes Castilho; Gustavo Vicentis de Oliveira Fernandes
Journal:  Polymers (Basel)       Date:  2022-03-29       Impact factor: 4.329

8.  A silk fibroin/chitosan/nanohydroxyapatite biomimetic bone scaffold combined with autologous concentrated growth factor promotes the proliferation and osteogenic differentiation of BMSCs and repair of critical bone defects.

Authors:  Yi Zhou; Xiaoyan Liu; Hongjiang She; Rui Wang; Fan Bai; Bingyan Xiang
Journal:  Regen Ther       Date:  2022-09-02       Impact factor: 3.651

9.  Relative Centrifugal Force (RCF; G-Force) Affects the Distribution of TGF-β in PRF Membranes Produced Using Horizontal Centrifugation.

Authors:  Zahra Kargarpour; Jila Nasirzade; Layla Panahipour; Richard J Miron; Reinhard Gruber
Journal:  Int J Mol Sci       Date:  2020-10-15       Impact factor: 6.208