Radiotherapy target volume definition in newly diagnosed high grade glioma using 18F-FET PET imaging and multiparametric perfusion MRI: A prospective study (IMAGG).

Gurvan Dissaux1, Brieg Dissaux2, Osman El Kabbaj3, Dorothy M Gujral4, Olivier Pradier5, Pierre-Yves Salaün6, Romuald Seizeur7, David Bourhis6, Douraied Ben Salem8, Solène Querellou6, Ulrike Schick5.   

Abstract

PURPOSE: The aim of this study was to prospectively investigate tumor volume delineation by amino acid PET and multiparametric perfusion magnetic resonance imaging (MRI) in patients with newly diagnosed, untreated high grade glioma (HGG).
MATERIALS AND METHODS: Thirty patients with histologically confirmed HGG underwent O-(2-[18F]-fluoroethyl)-l-tyrosine (18F-FET) positron emission tomography (PET), conventional Magnetic Resonance Imaging (MRI) as contrast-enhanced (CE) and fluid-attenuated inversion recovery (FLAIR) and multiparametric MRI as relative cerebral blood volume (rCBV) and permeability estimation map (K2). Areas of MRI volumes were semi-automatically segmented. The percentage overlap volumes, Dice and Jaccard spatial similarity coefficients (OV, DSC, JSC) were calculated.
RESULTS: The 18F-FET tumor volume was significantly larger than the CE volume (median 43.5 mL (2.5-124.9) vs. 23.8 mL (1.4-80.3), p = 0.005). The OV between 18F-FET uptake and CE volume was low (median OV 0.59 (0.10-1)), as well as spatial similarity (median DSC 0.52 (0.07-0.78); median JSC 0.35 (0.03-0.64)). Twenty-five patients demonstrated both rCBV and CE on MRI: The median rCBV tumor volume was significantly smaller than the median CE volume (p < 0.001). The OV was high (median 0.83 (0.54-1)), but the spatial similarity was low (median DSC 0.45 (0.04-0.83); median JSC 0.29 (0.07-0.71)). Twenty-eight patients demonstrated both K2 and CE on MRI. The median K2 tumor volume was not significantly larger than the median CE volume. The OV was high (median OV 0.90 (0.61-1)), and the spatial similarity was moderate (median DSC 0.75 (0.01-0.83); median JSC 0.60 (0.11-0.89)).
CONCLUSION: We demonstrated that multiparametric perfusion MRI volumes (rCBV, K2) were highly correlated with CE T1 gadolinium volumes whereas 18F-FET PET provided complementary information, suggesting that the metabolically active tumor volume in patients with newly diagnosed untreated HGG is critically underestimated by contrast enhanced MRI. 18F-FET PET imaging may help to improve target volume delineation accuracy for radiotherapy planning.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  (18)F-FET PET; GTV; High grade glioma; Multiparametric perfusion MRI; Radiotherapy target volume; Tumor volume

Mesh:

Substances:

Year:  2020        PMID: 32580001     DOI: 10.1016/j.radonc.2020.06.025

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  3 in total

1.  Effect of 3D Slicer Preoperative Planning and Intraoperative Guidance with Mobile Phone Virtual Reality Technology on Brain Glioma Surgery.

Authors:  Jun Liu; Xiaodong Li; Xueping Leng; Bo Zhong; Yanhong Liu; Liang Liu
Journal:  Contrast Media Mol Imaging       Date:  2022-05-24       Impact factor: 3.009

2.  Evaluation of FET PET Radiomics Feature Repeatability in Glioma Patients.

Authors:  Robin Gutsche; Jürgen Scheins; Martin Kocher; Khaled Bousabarah; Gereon R Fink; Nadim J Shah; Karl-Josef Langen; Norbert Galldiks; Philipp Lohmann
Journal:  Cancers (Basel)       Date:  2021-02-05       Impact factor: 6.639

3.  Radiotherapy Target Volume Definition in Newly Diagnosed High-Grade Glioma Using 18F-FET PET Imaging and Multiparametric MRI: An Inter Observer Agreement Study.

Authors:  Brieg Dissaux; Doria Mazouz Fatmi; Julien Ognard; Bastien Allard; Nathalie Keromnes; Amina Latreche; Amandine Lepeuve; Ulrike Schick; Vincent Bourbonne; Douraied Ben Salem; Gurvan Dissaux; Solène Querellou
Journal:  Tomography       Date:  2022-08-16
  3 in total