Literature DB >> 32577854

Misalignment of foveal pit and foveal bulge determined by ultrahigh-resolution SD-OCT in normal eyes.

Yoshitsugu Matsui1, Ryohei Miyata2, Eriko Uchiyama2, Hisashi Matsubara2, Mineo Kondo2.   

Abstract

PURPOSE: The foveal bulge (FB) results from a lengthening of the outer segments of the photoreceptors which then makes the central fovea arcuate in shape. The purpose of this study was to evaluate the morphological features and locations of the FB relative to the foveal pit (FP) in a single B-scan image.
METHODS: One hundred and forty-seven eyes of 147 healthy volunteers were studied. Horizontal and vertical B-scan optical coherence tomographic (OCT) images through the fovea were recorded by an ultrahigh-resolution spectral domain OCT (UHR-SD-OCT) instrument (Bi-μ, KOWA, Japan). The vertex of the FB and the center of the FP were identified with the ImageJ software. The distance between the FB and FP and the height of the FB were measured.
RESULTS: In the horizontal images, the vertex of the FB was on the nasal side of the center of the FP in 97 eyes (66%), on the temporal side in 42 eyes (29%), and the same position in 8 eyes (5%). In the vertical images, the vertex of the FB was superior to the center of the FP in 82 eyes (55%), inferior to the center of the FP in 45 eyes (31%), and the same position in 20 eyes (14%). The mean distance (± SD) between the FB and the FP was + 16.8 ± 30.1 μm in the horizontal images and + 8.27 ± 28.0 μm in the vertical images. The mean height (± SD) of the FB was 77.0 ± 4.78 μm in the horizontal images and 77.9 ± 5.05 μm in the vertical images. The height of the FB in the horizontal images was significantly correlated with refractive error in the multiple regression analysis (P = 0.041).
CONCLUSIONS: These results indicate that the vertex of the FB was not aligned with the center of the FP in the majority of the eyes of normal Japanese individuals in a single B-scan image. Analysis showed that eyes with less severe myopia had the higher height of the FB. This must be considered when interpreting the location of the vertex of the FB and the center of the FP in clinical situations.

Entities:  

Keywords:  Fovea; Foveal bulge; Foveal pit; Macular; Spectral domain optical coherence tomography; Ultrahigh-resolution optical coherence tomography

Year:  2020        PMID: 32577854     DOI: 10.1007/s00417-020-04813-6

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  3 in total

1.  Microstructural changes of photoreceptor layers detected by ultrahigh-resolution SD-OCT in patients with autosomal recessive bestrophinopathy.

Authors:  Kazushige Tsunoda; Gen Hanazono
Journal:  Am J Ophthalmol Case Rep       Date:  2022-09-24

2.  Distance between the center of the FAZ measured automatically and the highest foveal bulge using OCT-angiography in elderly healthy eyes.

Authors:  Takuhei Shoji; Hirokazu Ishii; Junji Kanno; Takanori Sasaki; Yuji Yoshikawa; Hisashi Ibuki; Kei Shinoda
Journal:  Sci Rep       Date:  2021-11-02       Impact factor: 4.379

3.  Detailed analyses of microstructure of photoreceptor layer at different severities of occult macular dystrophy by ultrahigh-resolution SD-OCT.

Authors:  Kazushige Tsunoda; Gen Hanazono
Journal:  Am J Ophthalmol Case Rep       Date:  2022-03-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.