Literature DB >> 32577662

Relationship between Anti-Spike Protein Antibody Titers and SARS-CoV-2 In Vitro Virus Neutralization in Convalescent Plasma.

Eric Salazar1,2, Suresh V Kuchipudi3,4, Paul A Christensen1, Todd N Eagar1,2, Xin Yi1,2, Picheng Zhao1, Zhicheng Jin1, S Wesley Long1,2,5, Randall J Olsen1,2,5, Jian Chen1,2, Brian Castillo1,2, Christopher Leveque1,2, Dalton M Towers6, Jason Lavinder6, Jimmy D Gollihar7, Jose Cardona7, Gregory C Ippolito6,8, Ruth H Nissly3, Ian M Bird3, Denver Greenawalt3, Randall M Rossi9, Abinhay Gontu3, Sreenidhi Srinivasan10, Indira B Poojary10, Isabella M Cattadori4,5,11, Peter J Hudson4,9,11, Nicole Joselyn12, Laura Prugar12, Kathleen Huie12, Andrew Herbert12, David W Bernard1,2, John Dye12, Vivek Kapur4,9,10, James M Musser1,2,5.   

Abstract

Newly emerged pathogens such as SARS-CoV-2 highlight the urgent need for assays that detect levels of neutralizing antibodies that may be protective. We studied the relationship between anti-spike ectodomain (ECD) and anti-receptor binding domain (RBD) IgG titers, and SARS-CoV-2 virus neutralization (VN) titers generated by two different in vitro assays using convalescent plasma samples obtained from 68 COVID-19 patients, including 13 who donated plasma multiple times. Only 23% (16/68) of donors had been hospitalized. We also studied 16 samples from subjects found to have anti-spike protein IgG during surveillance screening of asymptomatic individuals. We report a strong positive correlation between both plasma anti-RBD and anti-ECD IgG titers, and in vitro VN titer. Anti-RBD plasma IgG correlated slightly better than anti-ECD IgG titer with VN titer. The probability of a VN titer ≥160 was 80% or greater with anti-RBD or anti-ECD titers of ≥1:1350. Thirty-seven percent (25/68) of convalescent plasma donors lacked VN titers ≥160, the FDA-recommended level for convalescent plasma used for COVID-19 treatment. Dyspnea, hospitalization, and disease severity were significantly associated with higher VN titer. Frequent donation of convalescent plasma did not significantly decrease either VN or IgG titers. Analysis of 2,814 asymptomatic adults found 27 individuals with anti-RBD or anti-ECD IgG titers of ≥1:1350, and evidence of VN ≥1:160. Taken together, we conclude that anti-RBD or anti-ECD IgG titers can serve as a surrogate for VN titers to identify suitable plasma donors. Plasma anti-RBD or anti-ECD titer of ≥1:1350 may provide critical information about protection against COVID-19 disease.

Entities:  

Year:  2020        PMID: 32577662      PMCID: PMC7302218          DOI: 10.1101/2020.06.08.138990

Source DB:  PubMed          Journal:  bioRxiv


Introduction

The recently emerged SARS-CoV-2 novel coronavirus causing COVID-19 disease has spread globally and is now responsible for massive human morbidity and mortality. The pathogen was first documented to cause severe respiratory infections in humans in Wuhan, China, beginning in late December, 2019 (1). Soon thereafter, the SARS-CoV-2 virus was characterized as a member of the betacoronavirus genus and recognized to be related to several bat coronaviruses and Severe Acute Respiratory Syndrome (SARS-CoV) and Middle East Respiratory Syndrome (MERS) coronaviruses. SARS-CoV-2 spread was unusually rapid, and COVID-19 disease has now been reported in virtually all major population centers globally. In the United States, more than 1,500,000 COVID-19 cases have been documented and the virus has caused greater than 100,000 deaths nationwide. Many metropolitan regions have been especially affected, including but not limited to Seattle, New York City, Chicago, Miami, and Detroit (2). Management of COVID-19 infection has predominantly involved aggressive support care. Various treatment approaches are being studied, including direct viral replication inhibition (3), anti-inflammatory drugs, and passive antibody therapies. Currently, the only available passive antibody therapy for COVID-19 patients is transfusion of convalescent plasma obtained from recovered patients. The therapy is safe, and clinical trials assessing treatment or prophylactic efficacy are underway (4). Clinical trials assessing the use of hyperimmune IgG may begin soon. The Food and Drug Administration (FDA) has recommended (5) that convalescent plasma with a virus neutralizing antibody titer of ≥1:160 be used for therapeutic transfusion. However, assays to determine viral neutralizing antibody titers are not widely available, in part because they are labor intensive, cumbersome, and require a biosafety level 3 laboratory if live virus is used. Inasmuch as the VN titers in most donor plasma are not known prior to transfusion, a more facile method to identify suitable convalescent plasma donors is needed. This is an especially pressing matter, since an increasing number of COVID-19 patients are being treated globally with convalescent plasma. For example, under an FDA-approved expanded access protocol, nearly 20,000 transfusions have already occurred in the United States (6). The trimeric spike (S) protein made by SARS-CoV-2 is a large molecule that is critical to virus dissemination and pathogenesis. S protein is a densely glycosylated molecule present on the surface of the virus. S protein mediates binding of the SARS-CoV-2 virus to the host angiotensin-converting enzyme 2 (ACE2), thereby acting as the first step in cell entry and infection. Recent work has shown that SARS-CoV-2 and SARS-CoV-1 share the same ACE2 receptor. The molecular mechanism used by S protein to gain entry into host cells is complex and involves a region of the molecule known as the receptor binding domain (RBD). Engagement of S protein with the host receptor results in considerable changes in molecular conformation. The S protein has a critical function in host-cell entry, and thus is a major target for vaccine research and antibody-mediated VN efforts. Many lines of evidence from studies of SARS-CoV-1, MERS, and SARS-CoV-2 show that infected hosts make antibody directed against S protein (7–14). In addition, immunization with S protein can protect laboratory animals against experimental infection with SARS-CoV-1, MERS-CoV, and SARS-CoV-2 (15–19). Similarly, IgG directed against S protein has been reported to have in vitro VN activity. The goal of this study was to test the hypothesis that anti-ECD and/or anti-RBD IgG titer are correlated with VN titer, and thus could be used as a surrogate marker to identify plasma donors with titers above the FDA threshold value of 1:160. To test this hypothesis, we studied plasma and serum samples from 68 recovered COVID-19 patients with documented disease based on a positive molecular test for SARS-CoV-2. VN titer was determined independently in two laboratories using two different in vitro assays. The results show a strong positive correlation between anti-RBD and anti-ECD plasma IgG ELISA titers and the magnitude of in vitro VN. Specifically, we report that there is an 80% probability or greater of a VN titer at or above the FDA recommended level of 1:160 for COVID-19 convalescent plasma with anti-RBD or anti-ECD IgG titers of ≥1:1350. The results provide an important quantitative target for therapeutic and prophylactic treatments. We also find that convalescent donors maintain high-titer anti-RBD and anti-ECD IgG with in vitro VN activity over many weeks. Frequent plasma donations do not cause a significant decrease in antibody or VN titers. Finally, analysis of anti-ECD and anti-RBD IgG titers in 2,814 asymptomatic individuals in a surveillance cohort identified 27 individuals with anti-RBD or anti-ECD IgG titers of ≥1:1350, and evidence of VN ≥1:160. Thus, some asymptomatic individuals may have plasma suitable for therapeutic use and may have a degree of relative immunity against SARS-CoV-2.

Results

Plasma Donor Characteristics

Ninety-three samples from 68 unique COVID-19 convalescent plasma donors were assessed (Table 1). The average age was 45 (range 23 to 78) and 36 donors were female. Most donors had mild to moderate disease, with 44% (30/68) having a symptom severity score of 1, 32% (22/68) having score of 2, 10% (7/68) having a score of 3, 7% (5/68) having a score of 4, and 6% (4/68) having a score of 5. Sixteen donors required hospitalization, with an average length of stay of 4 d (range 2–13 d). Thirteen individuals donated more than once (range 1–7 times) with most (9/13) donating twice only. For all samples assessed, the median interval from symptom onset to donation visit was 32 d (range 17–53 d; IQR 28–36 d), and the median interval from symptom resolution to donation visit was 20 d (range 15–38 d; IQR 17–25 d).
Table 1:

Demographics and Characteristics of Convalescent Plasma Donors and Samples.

Sample #Subject IDGenderAgeSeverityHospitalized?LOS (Days)Symptom Duration (Days)Days Since Symptom OnsetDays Since Symptom ResolutionVisit #ECD (Titer)RBD (Titer)VN (Titer)VN2 (IC50)Clade
1HMH0001M441NONA320171150135032053.2A2a
2HMH0001M441NONA324212NANA64048.6A2a
3HMH0001M441NONA32724315045032053.3A2a
4HMH0001M441NONA33128415080032046.8A2a
5HMH0001M441NONA33431515080032096.3A2a
6HMH0001M441NONA33835645045016069.4A2a
7HMH0001M441NONA3413874504508071.5A2a
8HMH0002M541NONA132815150150401.5A2a
9HMH0003M361NONA72518145013508038.4B
10HMH0003M361NONA7282121504508010.4B
11HMH0003M361NONA733263450800807.6B
12HMH0003M361NONA73528445045008B
13HMH0003M361NONA74033545045032019.8B
14HMH0003M361NONA742356150450201.6B
15HMH0004F542NONA183214113501350320270.7NA
16HMH0004F542NONA183618213501350640128.5NA
17HMH0009F382NONA1230181450450804.8NA
18HMH0011F671NONA1128171050408A2a
19HMH0012F461NONA163014115045032030NA
20HMH0013F431NONA112817113503200320214.2A2a
21HMH0016F471NONA133219140504050320234.2A2a
22HMH0020F412NONA2171515020020NANA
23HMH0028M231NONA1231191150150200.6A2a
24HMH0029F661NONA622161150450809.3A2a
25HMH0032M652NONA1125141450405032094.8NA
26HMH0035M502NONA14281411350320032047.3B
27HMH0035M502NONA14382421350135064072B
28HMH0040M522NONA1229171NANA1280417A2a
29HMH0040M522NONA123523240504050640724.5A2a
30HMH0040M522NONA123725313504050320274A2a
31HMH0045F231NONA93324140501350128063.8A2a
32HMH0049F571NONA122715115045032047NA
33HMH0050M412NONA7302311350135032018.9NA
34HMH0050M412NONA73326215015032021.4NA
35HMH0051F501NONA163014115045016058.4NA
36HMH0052F273YES2173114113501350160100.1A2a
37HMH0053M292NONA102818145045016018.9NA
38HMH0055M613YES3143319113503200320134.1B
39HMH0057F442NONA634281450450160111.5A2a
40HMH0062F241NONA13321911350135010443.9A2a
41HMH0062F241NONA1335222135013501280288.8A2a
42HMH0069F491NONA62822145045080NAA2a
43HMH0069F491NONA6322624504508035.3A2a
44HMH0070F372NONA19381914501350160126.7A2a
45HMH0072F231NONA1329161000NANA
46HMH0072F231NONA133724250500NANA
47HMH0088F291NONA32118105020NAA2a
48HMH0089F422NONA183820145045016095A2a
49HMH0090M331NONA337341150150128051.3A2a
50HMH0099F541NONA120191505010NANA
51HMH0112F471NONA1323114504504078.9A2a
52HMH0113F521NONA9292011350150406.9NA
53HMH0116M271NONA16321614504502011.3NA
54HMH0117F272NONA10302011350135032032.7NA
55HMH0118F501NONA153419113504503208NA
56HMH0119F351NONA625191450450047.3NA
57HMH0120F411NONA31916145080032062.3NA
58HMH0121F511NONA7211411502004025.4NA
59HMH0133M512NONA425211150450320138.8NA
60HMH0135F472NONA123220140504050320174.4NA
61HMH0137F531NONA83830145080002.5NA
62HMH0143F492NONA10372711350320016072.4NA
63HMH0144M485YES3154025113503200640723NA
64HMH0144M485YES3154530240501350640423.1NA
65HMH0144M485YES315503534501350640453.8NA
66HMH0144M485YES31553384405040501280278.3NA
67HMH0156M591NONA622161405013501280814.8NA
68HMH0156M591NONA629232135013501280751.7NA
69HMH0158M332NONA10261611502004033.8NA
70HMH0162F513YES393425115045016028.2NA
71HMH0229M322NONA2140191450135080311.3NA
72HMH0234M402NONA12271511501504025NA
73HMH0245M515YES4143824113504050320145NA
74HMH0249M561NONA82214140504050320415.8NA
75HMH0255M402NONA14311714504504022NA
76HMH0260M442NONA524191405013501280468.5NA
77HMH0262F364YES21631151405040501280262.8A2a
78HMH0265F532NONA113120140504050320188NA
79HMH0313M783YES116362014050405016077.8NA
80HMH0363M561NONA73427145013508026.4NA
81HMH0368F372NONA929201450135016065.4NA
82HMH0369M411NONA21391811504508056.1NA
83HMH0376M524YES7142814113504050128074.8NA
84HMH0376M524YES714321824050405016090.7NA
85HMH0430M444YES41435211405040501280207.4NA
86HMH0576F503YES5241391000NANA
87HMH0580F433YES41229171405040501280752.3A2a
88HMH0580F433YES41235232135013501280421.4A2a
89HMH0598M464YES6293011405040501280365.7NA
90HMH0620M595YES61340271405040501280645.9NA
91HMH0634M535YES13163317140504050640148.1B
92HMH0699M613YES25353014050450640343NA
93HMH0879M504YES5143420140504050160178.1A2a

Abbreviations: F, Female; M, Male; LOS, Length of Stay; ECD, anti-spike ectodomain; RBD, Receptor Binding Domain; VN, Virus Neutralization

We also studied plasma from 16 asymptomatic individuals identified during an institutional surveillance program involving 2,814 individuals (manuscript in preparation). Of these 2,814 individuals, 102 had ELISA titers ≥50 (Supplemental Fig. 2). The average age of these 16 asymptomatic donors was 35 (range 20–49) and half were female (Supplemental Table 1).

VN Titers in Convalescent Plasma Donors

VN titers in samples from COVID-19 convalescent plasma donors were assessed with a traditional microneutralization assay evaluating protection from virus infection as determined by crystal violet staining 3 d post-infection. Plasma samples from the majority of donors (43/68; 63%) had a VN titer ≥1:160, the FDA recommended VN antibody titer for convalescent plasma to be used for therapeutic transfusion purposes. In contrast, 25 of 68 donors (37%) had a plasma titer below this recommended cutoff value (Figure 1A and Table 1).
Fig 1.

Patterns of VN and ELISA titers. A) Violin plot of distribution of VN titers at initial donation. Number of donor cases (total = 68) above and below the VN 160 cut off value are reported. B) Violin plots showing similar patterns of distribution of titers at initial donation for the two VN assays, together with the reciprocal ELISA IgG titers for plasma anti-ECD protein (ECD) and anti-RBD IgG (RBD). C) Pair-wise Pearson correlations showing the correlation coefficient (r) and related significant value (***= p<0.001) above the diagonal, and the bivariate scatterplots (jittered points) with linear regression fit (red line), confidence intervals (grey shading), correlation value (red point) and correlation ellipse (black ellipse) below the diagonal. The density plot (black line) and histogram of each variable is reported along the diagonal. Data are presented in log2-scale of reciprocal titers for VN, anti-ECD IgG and anti-RBD IgG, and in IC50 units for VN2.

Correlation between Two VN Assays

VN titers were assessed blinded (that is, without knowledge of the data generated by laboratory one) in a second laboratory with a different microneutralization assay (VN2) that determined the percentage of infected cells 24 h post-infection using a SARS-CoV-S specific mAb and a fluorescently labeled secondary antibody. The results from the two VN assays were highly correlated (r=0.66, P < 0.001) (Figure 1B and C).

Association between ELISA IgG Titers and VN Titer

Recognizing the urgent need for assays that could serve as a surrogate for VN, we assessed the association between ELISA anti-ECD and anti-RBD IgG titers and VN titers. The results of all four assays (anti-ECD and anti-RBD ELISAs, VN, and VN2) were strongly correlated (Figure 1C). Anti-RBD IgG had a numerically but not statistically greater correlation than anti-ECD (0.67 versus 0.62) with both microneutralization assays. We found that more than 80% of donors had a VN titer ≥1:160 in convalescent plasma when their serum anti-RBD or anti-EDC titers were 1:1350 or higher (Figure 2). Importantly, samples from naïve human plasma specimens obtained before the discovery of SARS-CoV-2 had no detectable titer in any of the four assays (data not shown).
Fig. 2.

Bar plots reporting the prevalence of donors with VN>160 for VN2, ECD or RBD. Probabilities of VN160 were plotted for six range classes, with an interclass interval of 1.8 log2 IC50 values (class 1 - <2; class 2 – 2,12; class 3 −12,42; class 4 – 42-147; class 5 – 147,512; class 6 - >512) or observed classes for ECD (n = 6) and RBD (n = 8) reciprocal ELISA titers. A spline curve (dotted line, smoothness shape=1) has been fitted to the probability values and standard errors (bars) are reported.

Relationship between Antibody Titers and Donor Characteristics

Inasmuch as approximately one-third of donors lacked convalescent plasma with the FDA-recommended VN titer cutoff of ≥1:160, we sought to identify donor characteristics that may be associated with a higher IgG titer. Such characteristics could aid donor recruitment efforts by identifying which recovered patients may have mounted a strong humoral response. We found that the presence of dyspnea during COVID-19 disease, hospitalization requirement, and more severe disease are all positively and significantly associated with higher IgG titers in all assays (Figure 3). Duration of disease symptoms was not associated with titer. Nor was there an association with time of plasma collection, since symptom onset and titer in the donor population occurred more than 14 days after symptom resolution (as required by the FDA). These results suggest that donors had already plateaued in their IgG titer at the time plasma was obtained, as there was no appreciable trend in titer increase over time (Supplemental Figure 1A and B).
Fig. 3.

Boxplots of VN, VN2, anti-ECD and anti RBD titers by A) dyspnea, B) hospitalization and C) disease severity (1= low severity, 5 high severity) at initial plasma donation from the 68 individual donors. The median, minimum, maximum, first and third quartile and extreme values are reported. Barplots showing case counts of donors above and below the VN 160 threshold stratified by whether they self-reported A) occurrence of dyspnea during symptomatic phase of disease; B) hospitalization; and, C) disease severity. Pair-wise t-test (significant comparisons (*=p<0.05, **= p<0.01, ***= p<0.001), odds ratio (OR) and relative risk (RR) with confidence intervals (CI) are also reported.

VN Titers Over Time from the Same Convalescent Plasma Donors

Thirteen individuals donated convalescent plasma more than once (range, 2 to 7 donations). The availability of longitudinal samples from the same plasma donors permitted us to assess the arc of anti-ECD and anti-RBD IgG titers and VN over time within individuals. There was no significant decrease in IgG titers as assessed by the ELISA or VN titer (Supplemental Figure 2), even among donors who donated twice/week for up to seven donations. Thus, we observed stable high titers both within and between individual donors.

Relationship between Infecting Strain Clade and VN Titer

We had available the virus genome sequences obtained from clinical samples (e.g., nasopharyngeal swab, oropharyngeal swab, or sputum) from 25 plasma donors. Eighty-four percent (21/25) of donors had been infected with strain A2a, and the remaining donors had been infected with strain B. Although the number of specimens is small, we tested the hypothesis that a relationship exists between the VN titer and genetic clade of the infecting SARS-CoV-2 strain. No definitive relationship was evident from analysis of the available data (Table 1).

Asymptomatic Individuals and VN Titers

Having established a relationship between IgG titer and in vitro SARS-CoV-2 VN titer, we next determined IgG titers in a sample of 2,814 asymptomatic adults screened under a surveillance protocol. We found that 67 of 2,814 (2.4%) individuals had anti-ECD and anti-RBD IgG ELISA titers of ≥1:150, of which 27 had anti-RBD or anti-ECD IgG titers of ≥1350. Among 16 of the 67 specimens chosen for VN analysis based on a range of titers [150 (n = 5), 450 (n = 5), and 1350 (n = 6)], seven had a VN titer ≥160. All individuals with a VN titer ≥160 had anti-RBD IgG titers of ≥1350. Conversely, with a single exception, all individuals with an anti-RBD IgG titer of ≥1350 had a VN titer ≥160 (Supplemental Table 1). Overall, among the 16 samples tested in this cohort, anti-RBD and anti-ECD ELISA titers also were strongly correlated with in vitro VN titer (R > 0.75, P = 0.001).

Discussion

In the absence of an efficacious vaccine to prevent COVID-19 disease, there is a pressing need for assays that detect neutralizing antibodies against SARS-CoV-2. Here we studied the relationship between anti-RBD and anti-ECD IgG titers present in convalescent plasma obtained from COVID-19 patients and in vitro SARS-CoV-2 VN. We discovered a strong positive association between anti-RBD and anti-ECD plasma IgG titer and in vitro VN titer. The data provide important evidence that anti-ECD and anti-RBD IgG titers are a suitable proxy for VN titer. Given the limited availability of VN assays, which are technically complex, require days to set up, run, and interpret, need a biosafety level 3 laboratory when performed with live native SARS-CoV-2 virus, and the relative ease with which ELISA assays can be implemented and performed in a high throughput fashion, we believe our data provide a guidepost for proxy assessments of VN titers relevant to the COVID-19 pandemic. We found that although both anti-ECD and anti-RBD IgG titers correlate well and significantly with in vitro VN, anti-RBD IgG titer had a tendency for a stronger correlation than anti-ECD IgG titer. This finding is consistent with a study showing clustering of VN epitopes in the SARS-CoV-1 RBD domain (20). Neutralizing monoclonal antibodies mapped to a region of RBD that has a critical role in attachment to the host ACE2 receptor. Given that the RBD is also the important region for ACE2 receptor binding for SARS-CoV-2 (21, 22), it is not surprising that anti-RBD IgG titers correlate well with VN titers. Importantly, our results show that anti-RBD or anti-ECD IgG titers of 1:1350 discriminated the presence of an adequate VN titer as recommended by the FDA for COVID-19 convalescent plasma with a probability of 80%. Future studies are required to determine if a VN titer of ≥1:160 has therapeutic benefit. Regardless, our findings clearly indicate that an anti-RBD IgG titer cutoff can be established that serves as a suitable proxy for VN titer. Our findings greatly expand on recent work showing a relationship between anti-S ELISA and microneutralization titer in 9 samples using a 48-hour post-infection microneutralization assay assessing “whole-well” optical density (11). Suthar et. al. have also demonstrated that RBD-specific IgG endpoint titer correlates well with a focus-reduction neutralization assay (10). Li et al. reported a positive correlation between SARS-CoV-2 VN titer and S-RBD–specific IgG titer, with a serum VN titer of 1:80 as approximately equivalent to a titer of 1:1280 for S-RBD–specific IgG (23). Because of differences in the VN assay used, their titers and those we report here are not equivalent. Harvala et. al. also reported VN and anti-spike ELISA titers were correlated (24), although there were several differences between that study and ours. For example, all donors were male, plasma was collected >28 days after symptom resolution, a different virus strain was used, no repeat donors were studied, and the association with clinical symptoms was not assessed. In addition, they did not study samples obtained during community screening of asymptomatic individuals. Herein, we compared results from two independent neutralization assays run blinded in two independent laboratories. The traditional VN assay (assay one) assessed protection from SARS-CoV-2 virus infection as determined by presence of cytopathic effect three days post-infection. In contrast, assay two (VN2) determines the percentage of SARS-CoV-2 virus-infected cells 24 hrs post-infection as a measure of early virus replication and susceptibility to host-cell infection. These two different approaches to VN assessment, and the robustness of the correlation between the results of the two different assays, adds confidence to our conclusion that anti-RBD IgG and anti-ECD IgG titers measured by ELISA serve as a very reliable surrogate of VN. Of particular note, approximately one-third of convalescent plasma donors in our study did not meet the FDA-recommended cutoff of 1:160 for VN titer. This finding is consistent with the 60% that did not meet the target neutralization threshold of 1:100 recently described in the Harvala study (24). However, the inability to directly compare titers between laboratories highlights an unmet need for the development of international standards to enable comparisons of SARS-CoV-2 serological assays between laboratories. An increasing number of COVID-19 patients are being treated globally with convalescent plasma. For example, under an FDA-approved expanded access protocol, 20,000 transfusions have already occurred in the United States alone (6). Inasmuch as convalescent donor plasma likely will continue to play an important role in treatment of COVID-19 patients as efforts are made to manufacture polyclonal hyperimmune immunoglobulin and neutralizing monoclonal antibodies, we felt it necessary to determine if certain donor characteristics may associate with high VN titer. We found that antibody titers were associated with disease severity and hospitalization status. Among all COVID-19 symptoms and donor characteristics assessed, the presence of dyspnea was the best symptom to discriminate the presence of an adequate IgG antibody titer. Although the sample size is small, we found that even for donors who donated plasma twice/week for up to seven donations, there was no significant decrease in titers as assessed by the IgG ELISAs and VN. We believe these data could inform efforts to recruit plasma donors for therapeutic purposes. The finding that increased COVID-19 disease severity is associated with a more robust humoral immune response is consistent with previous studies of SARS and dengue hemorrhagic fever patients (25), but contrasts with a recent report analyzing COVID-19 patients (26). It is possible that differences in antibody testing platforms could account for the contrasting observations. The list of emergency use authorized antibody testing platforms is rapidly expanding, and test performance, especially as it relates to virus neutralization, will be important to understand (27). Analysis of the available genomes for the SARS-CoV-2 strain pairs infecting convalescent donors and recipients found few differences in the inferred amino acid sequences, and no association between magnitude of humoral immunity, disease severity, or infecting strain genotype. Because our sample size is small, more work is required in this area. Several important matters remain unanswered with respect to anti-S protein IgG antibodies. First, although many believe, and some experimental animal infection data support (28), that antibodies directed against S protein confer protection from SARS-CoV-2 infection or reinfection, this remains unproven in humans. Second, although our data and work by others show a strong relationship between anti-S protein IgG titers and in vitro VN, it will be important to determine if IgG antibody titer against this protein is a significant correlate of protective immunity in humans. This is an especially important topic given the massive efforts globally on using S protein as a vaccine.

Limitations

Our study has several limitations. The study was retrospective, only IgG titers were analyzed, and all VN studies were conducted in vitro. Plasma from the convalescent donors was used for VN assays, whereas serum samples were used for ELISA assays. As such, the findings may not be entirely applicable to all antibody testing platforms or other sample types.

Conclusions

Taken together, the data clearly show that anti-RBD and anti-ECD IgG titers serve as important surrogates for in vitro VN activity. A substantial fraction of convalescent plasma donors may have VN titers below the FDA recommended cutoff of ≥1:160. Dyspnea, hospitalization, and higher disease severity were associated with higher VN titer. Importantly, a small percentage of asymptomatic individuals have virus-neutralizing antibodies, including some with a titer of ≥1:160. In the aggregate, it is reasonable to think that our findings provide impetus for widespread implementation of anti-RBD and anti-ECD IgG antibody titer testing programs. The resulting data could be useful in several settings, including, but not limited to, identification of plasma donors for therapeutic uses (e.g., convalescent plasma transfusion and/or source plasma for fractionation in the manufacture of hyperimmune globulin) (5, 11), assessment of recipients of candidate vaccines, assessment of recipients of passive immune therapies, assessment of previously infected individuals, and identification of asymptomatic individuals with antibody against SARS-CoV-2.

Methods

Convalescent Plasma Donors

Convalescent plasma was obtained by apheresis using the Trima Accel automated blood collection system (Terumo BCT) and processed by standard blood banking protocols under Houston Methodist human subjects protocol PRO00025121. FDA recommendations for COVID-19 convalescent plasma donor collection were followed (5). Each donor had laboratory-confirmed SARS-CoV-2 infection based on a positive RT-PCR test. All plasma was donated by recovered and healthy COVID-19 patients who had been asymptomatic for more than 14 days. Donors were between 18–65 years old. All donors provided written informed consent and tested negative for SARS-CoV-2 at the time of plasmapheresis. If eligible according to standard blood donor criteria, donors were enrolled in a frequent plasmapheresis program. Donors were documented to be negative for anti-HLA antibodies, hepatitis B, C, HIV, HTLV I/II, Chagas disease, WNV, Zika virus, and syphilis per standard blood banking practices. Disease symptoms (fever, chills, productive or non-productive cough, dyspnea, fatigue, myalgias, headache, runny nose, sore throat, nausea, vomiting, diarrhea, abdominal discomfort, loss of smell or taste, and other), disease severity, hospitalization requirement, and hospitalization course were assessed for each donor. A severity score was assigned as follows: 0 = asymptomatic; 1 = mild disease without dyspnea; 2 = moderate disease with dyspnea that did not require hospitalization; 3 = moderate disease with dyspnea that required hospitalization; 4 = severe disease that required supplemental oxygen; 5 = critical disease that required intensive care unit admission and/or intubation/mechanical ventilation. An aliquot of convalescent plasma product was used for virus microneutralization assays. Studies were conducted with the approval of the Houston Methodist Research Institute ethics review board, and with informed patient or legally-authorized representative consent when applicable.

Asymptomatic Donors and VN titers

Samples from asymptomatic individuals were obtained from volunteers screened through an IRB-approved community surveillance protocol (manuscript in preparation). Analysis of 2,814 asymptomatic adults found that 67 (2.4%) had an anti-ECD and anti-RBD IgG ELISA titers of ≥1:150. Sixteen of these 67 specimens were chosen for VN analysis based on the range of titers, including 1:150 (n = 5), 1:450 (n = 5), and 1:1350 (n = 6) (Table S1).

Specimens from SARS-CoV-2 Naïve Donors

Ten naïve human plasma specimens (negative controls) were obtained from samples biobanked in Houston well before SARS-CoV-2 was described in China, the United States, or elsewhere.

RT-PCR Testing for SARS-CoV-2 Infection

Symptomatic patients with a high degree of suspicion for COVID-19 disease were tested in the Molecular Diagnostics Laboratory at Houston Methodist Hospital using an assay filed for under Emergency Use Authorization (EUA) from the U.S. Food and Drug Administration (27). The assay follows the protocol published by the World Health Organization (29) and uses a 7500 Fast Dx instrument (Applied Biosystems) and 7500 SDS software (Applied Biosystems). Testing was performed on nasopharyngeal or oropharyngeal swabs immersed in universal transport media (UTM), bronchoalveolar lavage fluid, or sputum treated with dithiothreitol (DTT).

SARS-CoV-2 ELISAs

Detailed ELISA methods have been recently described (30). The ELISA used to measure anti-spike IgG antibodies in donor serum specimens was performed as follows. Briefly, ECD purified recombinant protein used comprises amino acid residues 1 – 1208, and the RBD comprises amino acids 319 – 591 of SARS-CoV-2 spike protein (GenBank MN908947). Microtiter plates were coated with either purified recombinant SARS-CoV-2 ECD or RBD. Human mAb CR3022 that targets the receptor-binding domain (RBD) of SARS-CoV (31) was used as a positive control. Negative serum control was included on each microtiter plate. Serial dilutions of serum were added, incubated for 1 h, washed, incubated with goat anti-human IgG Fab HRP (Sigma A0293), and washed. ELISA substrate (1-step Ultra TMB, Thermo Scientific cat# 34028) was added, the plates were developed until the top dilution reached the saturation point, and the reaction was stopped with H2SO4. Plates were read at an absorbance of 450 nm. A similar ELISA was used to study anti-spike ECD antibody titers in serum obtained from surveilled asymptomatic individuals. Recombinant proteins were produced as described above. All samples were tested with an initial screen assay and IgG antibody titers were subsequently performed on positive samples. For the screening assay, patient serum samples and negative control samples were diluted 1:50 in PBS containing 2% nonfat milk prior to addition to the plate. Patient sera that were identified as positive by the screening assay were subsequently titered by 1:3 serial dilutions in PBS-M to create 1:50, 1:150, 1:450, 1:1350, and 1:4050 final dilutions. Titer was defined as the last dilution showing an optical density greater than average negative control plus three standard deviations.

SARS-CoV-2 Microneutralization Assay (VN)

The ability of plasma samples to neutralize SARS-CoV-2 host-cell infection was determined with a traditional VN assay using SARS-CoV-2 strain USA-WA1/2020 (NR-52281-BEI resources), as previously described for SARS-CoV (15). The assay was performed in triplicate, and a series of eight two-fold serial dilutions of the plasma or serum were assessed. Briefly, 100 tissue culture infective dose 50 (TCID50) units of SARS-CoV-2 was added to two-fold dilutions of heat inactivated serum or plasma, and incubated for 1 h at 37°C. The virus and plasma mixture was added to Vero E6 cells grown in a 96-well microtiter plate, incubated for 3 d, after which the host cells were treated for 1 h with crystal violet-formaldehyde stain (0.013% crystal violet, 2.5% ethanol, and 10% formaldehyde in 0.01 M PBS). The endpoint of the microneutralization assay was designated as the highest plasma dilution at which all three, or two of three, wells are not protected from virus infection, as assessed by visual examination.

SARS-CoV-2 Microneutralization Assay Two

A second SARS-CoV-2 microneutralization assay (VN2) was adapted from an assay used to study Ebola virus (32). This assay also used SARS-CoV-2 strain WA1. Plasma specimens were diluted in cell culture media in duplicate. Serum from naïve and SARS-CoV-2 convalescent individuals was used as negative and positive controls, respectively. Diluted plasma was mixed with the SARS-CoV-2 WA1 strain, incubated at 37° C for 1 h, then added to Vero-E6 cells at a target MOI of 0.4. Unbound virus was removed after 1 h incubation at 37° C and culture media was added. Cells were fixed 24 h post-infection, and the number of infected cells was determined using SARS-CoV-S specific mAb (Sino Biological 401430-R001) and fluorescently labeled secondary antibody. The percent of infected cells was determined with an Operetta high content imaging system (PerkinElmer) and Harmonia software (33). Percent neutralization for each plasma sample at each dilution was determined relative to untreated, virus only control wells.

SARS-CoV-2 Genome Sequencing and Analysis, and Clade Assignment

Libraries for whole virus genome sequencing were prepared according to version 1 or 3 of the ARTIC nCoV-2019 sequencing protocol (34). Long reads were generated with the LSK-109 sequencing kit, 24 native barcodes (NBD104 and NBD114 kits), and a GridION instrument (Oxford Nanopore). Short reads were generated with the NexteraXT kit and a MiSeq or NextSeq 550 instrument (Illumina). Whole genome alignments of consensus virus genome sequence generated from the ARTIC nCoV-2019 bioinformatics pipeline were trimmed to the start of orf1ab and the end of orf10 and used to generate a phylogenetic tree using RAxML (https://cme.h-its.org/exelixis/web/software/raxml/index.html). Trees were visualized and annotated with CLC Genomics Workbench v20 (Qiagen). SARS-CoV-2 clade assignment was based on procedures described elsewhere (35).

Statistical Analysis

To assess the correlation between VNs, anti-RBD and anti-ECD ELISA titer data, pair-wise Pearson correlations were performed using the entire dataset, i.e. individuals with single and repeated measurements. To identify the prevalence of donors with VN titers ≥1:160, the frequency distribution of these cases by titer classes critical for RBD, ECD, and VN2 was quantified. Generalized Liner model (GLM), using the first plasma donation data only, was performed between the same variables, as a response, and each of the following predictor factors: dyspnea (yes, no), disease severity (five classes as described above), hospitalization (yes, no) gender (male, female), and age combined into five age groups (<=30, 31–40, 41–50, 51–60 and >60). For variables with more than two factors, a post-hoc t-test (with Bonferroni correction) was used to identify significant pair-wise differences. A linear mixed effect (LME) model was used to analyze the relationship between VNs, anti-RBD, and anti-ECD protein titers, as responses, and days since symptoms, as numerical predictors. Here, we used the whole data set and included the individual’s ID as the random factor, to consider multiple sampling. A similar analysis was used for duration of symptoms but using GLM and selecting only the cases at the first visit. Analysis were performed using log2-trasformed numeric data and the R statistical computing platform (http://www.R-project.org, v. 4.0.0).
  23 in total

1.  Antibodies from a Human Survivor Define Sites of Vulnerability for Broad Protection against Ebolaviruses.

Authors:  Anna Z Wec; Andrew S Herbert; Charles D Murin; Elisabeth K Nyakatura; Dafna M Abelson; J Maximilian Fels; Shihua He; Rebekah M James; Marc-Antoine de La Vega; Wenjun Zhu; Russell R Bakken; Eileen Goodwin; Hannah L Turner; Rohit K Jangra; Larry Zeitlin; Xiangguo Qiu; Jonathan R Lai; Laura M Walker; Andrew B Ward; John M Dye; Kartik Chandran; Zachary A Bornholdt
Journal:  Cell       Date:  2017-05-18       Impact factor: 41.582

2.  A human monoclonal antibody blocking SARS-CoV-2 infection.

Authors:  Chunyan Wang; Wentao Li; Dubravka Drabek; Nisreen M A Okba; Rien van Haperen; Albert D M E Osterhaus; Frank J M van Kuppeveld; Bart L Haagmans; Frank Grosveld; Berend-Jan Bosch
Journal:  Nat Commun       Date:  2020-05-04       Impact factor: 14.919

3.  Effect of Convalescent Plasma Therapy on Time to Clinical Improvement in Patients With Severe and Life-threatening COVID-19: A Randomized Clinical Trial.

Authors:  Ling Li; Wei Zhang; Yu Hu; Xunliang Tong; Shangen Zheng; Juntao Yang; Yujie Kong; Lili Ren; Qing Wei; Heng Mei; Caiying Hu; Cuihua Tao; Ru Yang; Jue Wang; Yongpei Yu; Yong Guo; Xiaoxiong Wu; Zhihua Xu; Li Zeng; Nian Xiong; Lifeng Chen; Juan Wang; Ning Man; Yu Liu; Haixia Xu; E Deng; Xuejun Zhang; Chenyue Li; Conghui Wang; Shisheng Su; Linqi Zhang; Jianwei Wang; Yanyun Wu; Zhong Liu
Journal:  JAMA       Date:  2020-08-04       Impact factor: 56.272

4.  Antibody responses to SARS-CoV-2 in patients with COVID-19.

Authors:  Quan-Xin Long; Bai-Zhong Liu; Hai-Jun Deng; Gui-Cheng Wu; Kun Deng; Yao-Kai Chen; Pu Liao; Jing-Fu Qiu; Yong Lin; Xue-Fei Cai; De-Qiang Wang; Yuan Hu; Ji-Hua Ren; Ni Tang; Yin-Yin Xu; Li-Hua Yu; Zhan Mo; Fang Gong; Xiao-Li Zhang; Wen-Guang Tian; Li Hu; Xian-Xiang Zhang; Jiang-Lin Xiang; Hong-Xin Du; Hua-Wen Liu; Chun-Hui Lang; Xiao-He Luo; Shao-Bo Wu; Xiao-Ping Cui; Zheng Zhou; Man-Man Zhu; Jing Wang; Cheng-Jun Xue; Xiao-Feng Li; Li Wang; Zhi-Jie Li; Kun Wang; Chang-Chun Niu; Qing-Jun Yang; Xiao-Jun Tang; Yong Zhang; Xia-Mao Liu; Jin-Jing Li; De-Chun Zhang; Fan Zhang; Ping Liu; Jun Yuan; Qin Li; Jie-Li Hu; Juan Chen; Ai-Long Huang
Journal:  Nat Med       Date:  2020-04-29       Impact factor: 53.440

5.  Characterization of Ebola convalescent plasma donor immune response and psoralen treated plasma in the United States.

Authors:  Christina L Dean; Jay W Hooper; John M Dye; Samantha E Zak; Scott A Koepsell; Laurence Corash; Richard J Benjamin; Steve Kwilas; Shannon Bonds; Anne M Winkler; Colleen S Kraft
Journal:  Transfusion       Date:  2020-03-04       Impact factor: 3.157

6.  Prophylactic and postexposure efficacy of a potent human monoclonal antibody against MERS coronavirus.

Authors:  Davide Corti; Jincun Zhao; Mattia Pedotti; Luca Simonelli; Sudhakar Agnihothram; Craig Fett; Blanca Fernandez-Rodriguez; Mathilde Foglierini; Gloria Agatic; Fabrizia Vanzetta; Robin Gopal; Christopher J Langrish; Nicholas A Barrett; Federica Sallusto; Ralph S Baric; Luca Varani; Maria Zambon; Stanley Perlman; Antonio Lanzavecchia
Journal:  Proc Natl Acad Sci U S A       Date:  2015-07-27       Impact factor: 11.205

7.  Neutralizing epitopes of the SARS-CoV S-protein cluster independent of repertoire, antigen structure or mAb technology.

Authors:  Jody D Berry; Kevin Hay; James M Rini; Meng Yu; Linfa Wang; Francis A Plummer; Cindi R Corbett; Anton Andonov
Journal:  MAbs       Date:  2010-01-27       Impact factor: 5.857

8.  Human monoclonal antibody combination against SARS coronavirus: synergy and coverage of escape mutants.

Authors:  Jan ter Meulen; Edward N van den Brink; Leo L M Poon; Wilfred E Marissen; Cynthia S W Leung; Freek Cox; Chung Y Cheung; Arjen Q Bakker; Johannes A Bogaards; Els van Deventer; Wolfgang Preiser; Hans Wilhelm Doerr; Vincent T Chow; John de Kruif; Joseph S M Peiris; Jaap Goudsmit
Journal:  PLoS Med       Date:  2006-07       Impact factor: 11.069

9.  Remdesivir for the Treatment of Covid-19 - Final Report.

Authors:  John H Beigel; Kay M Tomashek; Lori E Dodd; Aneesh K Mehta; Barry S Zingman; Andre C Kalil; Elizabeth Hohmann; Helen Y Chu; Annie Luetkemeyer; Susan Kline; Diego Lopez de Castilla; Robert W Finberg; Kerry Dierberg; Victor Tapson; Lanny Hsieh; Thomas F Patterson; Roger Paredes; Daniel A Sweeney; William R Short; Giota Touloumi; David Chien Lye; Norio Ohmagari; Myoung-Don Oh; Guillermo M Ruiz-Palacios; Thomas Benfield; Gerd Fätkenheuer; Mark G Kortepeter; Robert L Atmar; C Buddy Creech; Jens Lundgren; Abdel G Babiker; Sarah Pett; James D Neaton; Timothy H Burgess; Tyler Bonnett; Michelle Green; Mat Makowski; Anu Osinusi; Seema Nayak; H Clifford Lane
Journal:  N Engl J Med       Date:  2020-10-08       Impact factor: 91.245

10.  DNA vaccine protection against SARS-CoV-2 in rhesus macaques.

Authors:  Jingyou Yu; Lisa H Tostanoski; Lauren Peter; Noe B Mercado; Katherine McMahan; Shant H Mahrokhian; Joseph P Nkolola; Jinyan Liu; Zhenfeng Li; Abishek Chandrashekar; David R Martinez; Carolin Loos; Caroline Atyeo; Stephanie Fischinger; John S Burke; Matthew D Slein; Yuezhou Chen; Adam Zuiani; Felipe J N Lelis; Meghan Travers; Shaghayegh Habibi; Laurent Pessaint; Alex Van Ry; Kelvin Blade; Renita Brown; Anthony Cook; Brad Finneyfrock; Alan Dodson; Elyse Teow; Jason Velasco; Roland Zahn; Frank Wegmann; Esther A Bondzie; Gabriel Dagotto; Makda S Gebre; Xuan He; Catherine Jacob-Dolan; Marinela Kirilova; Nicole Kordana; Zijin Lin; Lori F Maxfield; Felix Nampanya; Ramya Nityanandam; John D Ventura; Huahua Wan; Yongfei Cai; Bing Chen; Aaron G Schmidt; Duane R Wesemann; Ralph S Baric; Galit Alter; Hanne Andersen; Mark G Lewis; Dan H Barouch
Journal:  Science       Date:  2020-05-20       Impact factor: 47.728

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.