Literature DB >> 32568694

Nanochannel-driven rapid capture of sub-nanogram level biomarkers for painless preeclampsia diagnosis.

Ye-Eun Kang1, Keum-Yong Seong1, Sang-Gu Yim1, Yechan Lee1, Sung-Min An1, Seung Chul Kim2, Kyujung Kim3, Beum-Soo An1, Kyu-Sup Lee2, Seung Yun Yang4.   

Abstract

Preeclampsia (PE) is a pregnancy-specific hypertensive syndrome recognized as the leading cause of maternal and fetal morbidity and mortality worldwide. Painful blood-collection procedures or low accuracy of non-invasive approaches require faster, patient-friendly, and more sensitive diagnostic technologies. Here we report a painless, highly sensitive detection platform using nanoporous microneedles (nMNs) that enables rapid capture of biomarkers present at sub-nanogram levels. The highly porous nanostructures on the nMN surface were prepared by anodization of aluminum MN and then functionalized by immobilization of capture antibodies to detect target biomarkers based on an immunoassay method. The immuno-functionalized nMN array demonstrated rapid capture of an estrogen (E2) biomarker for PE following a 1-min incubation and exhibited a concentration-dependent change in fluorescence intensity over the E2 range of 0.5 ng mL-1 to 1000 ng mL-1 after treatment with fluorescence-detection antibodies. Remarkably, the nMN patch selectively detected sub-nanogram-levels of E2 in subcutaneous interstitial fluid from rats with increased diagnostic accuracy as compared with commercial immunoassay kits. This bio-functionalized nMN platform showed improved biosensing capability for multiple PE-related biomarkers, including hormones and proteins. Furthermore, this painless method demonstrated efficacy as a point-of-need diagnostic platform using portable smartphone-based fluorescence microscope to obtain fluorescence images of biomarker-captured nMN arrays.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Immunoassay; Microneedle; Painless diagnosis; Preeclampsia

Mesh:

Substances:

Year:  2020        PMID: 32568694     DOI: 10.1016/j.bios.2020.112281

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Microneedle arrays for the treatment of chronic wounds.

Authors:  Lindsay Barnum; Mohamadmahdi Samandari; Tannin A Schmidt; Ali Tamayol
Journal:  Expert Opin Drug Deliv       Date:  2020-10-08       Impact factor: 6.648

Review 2.  Microneedle-Based Device for Biological Analysis.

Authors:  Huiting Lu; Shah Zada; Lingzhi Yang; Haifeng Dong
Journal:  Front Bioeng Biotechnol       Date:  2022-04-21

3.  The relationship between polymorphisms of microRNA and preeclampsia: A protocol for meta-analysis and bioinformatics prediction.

Authors:  Tao Li; Yihong Chen; Yi Lai; Guoqian He; Guolin He
Journal:  Medicine (Baltimore)       Date:  2021-04-09       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.