Literature DB >> 3256757

Continuous estimation of parameters in skin electrical admittance from simultaneous measurements at two different frequencies.

L Mørkrid, Z G Qiao.   

Abstract

Mesh:

Year:  1988        PMID: 3256757     DOI: 10.1007/bf02447503

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  11 in total

1.  Analysis for the change of skin impedance.

Authors:  T Yamamoto; Y Yamamoto
Journal:  Med Biol Eng Comput       Date:  1977-05       Impact factor: 2.602

Review 2.  Characteristics of the metal-tissue interface of stimulation electrodes.

Authors:  A M Dymond
Journal:  IEEE Trans Biomed Eng       Date:  1976-07       Impact factor: 4.538

3.  Simultaneous measurement of electrical admittance, blood flow and temperature at the same skin site with a specially designed probe.

Authors:  Z G Qiao; L Mørkrid; S Grimnes
Journal:  Med Biol Eng Comput       Date:  1987-05       Impact factor: 2.602

4.  Three-electrode method to study event-related responses in skin electrical potential, admittance and blood flow.

Authors:  Z G Qiao; L Morkrid; S Grimnes
Journal:  Med Biol Eng Comput       Date:  1987-09       Impact factor: 2.602

5.  Nonlinearity of cardiac pacemaker electrodes.

Authors:  D Jaron; S A Briller; H P Schwan; D B Geselowitz
Journal:  IEEE Trans Biomed Eng       Date:  1969-04       Impact factor: 4.538

6.  Thermoregulatory and rhythm-generating mechanisms governing the sudomotor and vasoconstrictor outflow in human cutaneous nerves.

Authors:  G Bini; K E Hagbarth; P Hynninen; B G Wallin
Journal:  J Physiol       Date:  1980-09       Impact factor: 5.182

7.  A unified approach to represent metal electrode polarization.

Authors:  H H Sun; B Onaral
Journal:  IEEE Trans Biomed Eng       Date:  1983-07       Impact factor: 4.538

8.  Nonlinear AC and DC polarization of platinum electrodes.

Authors:  R W Simpson; J G Berberian; H P Schwan
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

9.  Signal source impedance of implanted pacemaker electrodes estimated from the spectral ratio between loaded and unloaded electrograms in man.

Authors:  L Mörkrid; O J Ohm; E Hammer
Journal:  Med Biol Eng Comput       Date:  1980-03       Impact factor: 2.602

10.  Psychogalvanic reflex and changes in electrical parameters of dry skin.

Authors:  S Grimnes
Journal:  Med Biol Eng Comput       Date:  1982-11       Impact factor: 2.602

View more
  2 in total

1.  Characteristics of phase angle, extrapolated conductance and ion relaxation time in the low-frequency admittance locus plot of human palmar skin.

Authors:  Z G Qiao; L Mørkrid; N K Vøllestad
Journal:  Med Biol Eng Comput       Date:  1994-03       Impact factor: 2.602

2.  Relationships between parameters describing low-frequency electrical admittance locus plot of human palmar skin.

Authors:  Z G Qiao; L Mørkrid
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.