Literature DB >> 3256742

Mathematical simulation of an amperometric enzyme-substrate electrode with a pO2 basic sensor. Part 2. Mathematical simulation of the glucose oxidase glucose electrode.

K Lemke.   

Abstract

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3256742     DOI: 10.1007/bf02441922

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  13 in total

1.  [A measuring probe for glucose. 2. International state; further measurements, studies and experiences with the glucose probe].

Authors:  P G Reitnauer
Journal:  Z Med Labortech       Date:  1975

2.  Diffusion and the limiting substrate in two-substrate immobilized enzyme systems.

Authors:  J K Leypoldt; D A Gough
Journal:  Biotechnol Bioeng       Date:  1982-12       Impact factor: 4.530

3.  [Galvanic primary cell as a basic sensor for the GOD-glucose electrode].

Authors:  G Zahlmann; K Lemke
Journal:  Z Med Lab Diagn       Date:  1986

4.  Enzyme electrode for L-amino acids and glucose.

Authors:  M Nanjo; G G Guilbault
Journal:  Anal Chim Acta       Date:  1974-12       Impact factor: 6.558

5.  [Blood sugar determination using an enzyme electrode].

Authors:  M Notin; R Guillien; P Nabet
Journal:  Ann Biol Clin (Paris)       Date:  1972       Impact factor: 0.459

6.  Assessment and optimisation of dip-coating procedure for the preparation of electroenzymic glucose transducers.

Authors:  P A Rea; P Rolfe; P J Goddard
Journal:  Med Biol Eng Comput       Date:  1985-03       Impact factor: 2.602

7.  Glycaemic control in pancreatectomized dogs with a wearable artificial endocrine pancreas.

Authors:  M Shichiri; R Kawamori; Y Goriya; Y Yamasaki; M Nomura; N Hakui; H Abe
Journal:  Diabetologia       Date:  1983-03       Impact factor: 10.122

8.  Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell.

Authors:  P Abel; A Müller; U Fischer
Journal:  Biomed Biochim Acta       Date:  1984

9.  A miniature glucose sensor, implantable in the blood stream.

Authors:  T Kondo; K Ito; K Ohkura; K Ito; S Ikeda
Journal:  Diabetes Care       Date:  1982 May-Jun       Impact factor: 19.112

10.  The enzyme electrode.

Authors:  S J Updike; G P Hicks
Journal:  Nature       Date:  1967-06-03       Impact factor: 49.962

View more
  1 in total

1.  Mathematical stimulation of an amperometric enzyme-substrate electrode with a pO2 basic sensor. Part 1. Mathematical model and simulation of the pO2 basic sensor.

Authors:  K Lemke
Journal:  Med Biol Eng Comput       Date:  1988-09       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.