Literature DB >> 32564492

Anesthesia and potential aerosol generation during magnetic resonance imaging in children with COVID-19.

Elizabeth Drum1, Heather McClung Pasqualino1, Rajeev Subramanyam1.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32564492      PMCID: PMC7323391          DOI: 10.1111/pan.13951

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.129


× No keyword cloud information.

INTRODUCTION

The American College of Radiology recommends minimizing magnetic resonance imaging (MRI) in COVID‐19 patients, postponing nonurgent examinations, and using alternative imaging. Sedation/anesthesia are aerosol‐generating procedures (AGP) due to the requirement of bag‐mask ventilation, intubation, and extubation with consequent risk of exposure to healthcare workers. This is complicated by limitation in the use of personal protective equipment (PPE) in the magnet zone (Zone IV). We describe our experience for children requiring anesthesia for emergency MRI during the COVID‐19 outbreak in Philadelphia.

METHODS

This study protocol received an exempt from IRB. Between March 26, 2020, and May 11, 2020, we performed chart review to identify children with laboratory diagnosed or probable COVID‐19 who underwent MRI that necessitated general anesthesia. Electronic medical record query was performed for all anesthesia procedures, and children who had MR procedures under general anesthesia were identified.

RESULTS

A total of 149 MR procedures were performed in the time period. Among this, we identified four children with COVID‐19 who underwent emergency MRI that necessitated general anesthesia (Table 1). The care of the COVID‐19 patients required multidisciplinary conversation and planning. For the management, we divided MRI into zones to reduce exposure to healthcare workers (Figure S1) and identified themes and workflow for safe care of COVID‐19 patients and healthcare workers during MRI and AGP (Table S1). Team members expected to enter Zone IV removed all ferromagnetic material prior to donning PPE. Metal screening for staff and patient was performed ahead of time. We identified a negative pressure room equipped to provide general anesthesia, used high‐quality viral filtration in the breathing circuit, and verified the presence of anesthesia scavenging system to prevent aerosol spread. The transport path for the patient to and from the MR area was clearly defined along with the assistance of hospital security. The PPE used is reported in Table 1.
Table 1

COVID‐19, patient demographics, and the use of N95

Case No.COVID‐19 StatusAge/GenderGenderIndication for MRIType of MRIAnesthetic techniquePPE usedN95 used in magnet zone
1Lab confirmed a 31 moMaleShoulder abscessShoulder; whole bodyIntubation and extubation in NP room

Headcover

Shoe cover

Gown and gloves

Eye protection

N95 mask

Yes
2Probable5 moMaleEvaluate cystic structure, history ventriculitisBrainIntubation and extubation in NP room

Headcover

Shoe cover

Gown and gloves

Eye protection

N95 mask

Yes
3Probable24 moFemaleAbdominal massAbdomen and PelvisIntubation and extubation in NP room

Headcover

Shoe cover

Gown and gloves

Eye protection

N95 mask

Yes
4Probable7 yFemaleStatus post–lung transplant, liver neoplasmBrain; Whole body PET MRIIntubation and extubation in NP room

Headcover

Shoe cover

Gown and gloves

Eye protection

N95 mask

Yes

Probable COVID‐19 status = resident of endemic area based on our hospital threshold of 6 cases/1000 persons.

Abbreviations: MRI, magnetic resonance imaging; NP, negative pressure; PET, positron emission tomography; PPE, personal protective equipment.

Lab, laboratory using polymerase chain reaction on a nasopharyngeal swab.

COVID‐19, patient demographics, and the use of N95 Headcover Shoe cover Gown and gloves Eye protection N95 mask Headcover Shoe cover Gown and gloves Eye protection N95 mask Headcover Shoe cover Gown and gloves Eye protection N95 mask Headcover Shoe cover Gown and gloves Eye protection N95 mask Probable COVID‐19 status = resident of endemic area based on our hospital threshold of 6 cases/1000 persons. Abbreviations: MRI, magnetic resonance imaging; NP, negative pressure; PET, positron emission tomography; PPE, personal protective equipment. Lab, laboratory using polymerase chain reaction on a nasopharyngeal swab.

DISCUSSION

Our routine MRI anesthesia management is with natural airway or laryngeal mask airway. There was a change in the technique with COVID‐19 patients which included airway management in a negative pressure room and expanded PPE to prevent aerosol generation. Although surgical masks are an MR safe alternative, due to AGP this was considered insufficient. As of writing this report, not all types of respirators are tested in the MR environment. Powered air‐purifying respirators (PAPR) are likely not acceptable due to MRI safety concerns. A recent study evaluated the use of European respirators in the MR environment on a three‐dimensionally printed phantom face. They found considerable force/torque in the MR environment that could disrupt the tight mask seal during AGP and were regarded as MR unsafe. This study did not evaluate N95 masks, which are a commonly used respirator in the United States. N95 masks consist of a metal nosepiece that could pose a hazard in the magnet zone of MRI and may not have been evaluated for MR safety. We checked the interaction of the N95 respirator (3M, St Paul, Minnesota, USA) metal piece with the magnet by wearing it and moving into an empty MR room. There was a tug felt when the face with N95 on was close to the bore with no difference in “feel” away from the gauss line (away from the bore). Although on the basis of this alone, we cannot say if N95 is protective to the wearer in the magnet zone but the possibility of its use should be considered until further data are available.

ETHICAL APPROVAL

.Children's Hospital of Philadelphia IRB#20‐017294 Review — Exemption Granted.

CONFLICT OF INTEREST

Rajeev Subramanyam is Associate Editor for Pediatric Anesthesia. Rajeev Subramanyam has research funding from Masimo Foundation, Irvine, CA. Other authors have no disclosures. Figure S1 Click here for additional data file. Table S1 Click here for additional data file.
  2 in total

1.  Intubation and Ventilation amid the COVID-19 Outbreak: Wuhan's Experience.

Authors:  Lingzhong Meng; Haibo Qiu; Li Wan; Yuhang Ai; Zhanggang Xue; Qulian Guo; Ranjit Deshpande; Lina Zhang; Jie Meng; Chuanyao Tong; Hong Liu; Lize Xiong
Journal:  Anesthesiology       Date:  2020-06       Impact factor: 7.892

2.  Respirators and surgical facemasks for COVID-19: implications for MRI.

Authors:  O M Murray; J M Bisset; P J Gilligan; M M Hannan; J G Murray
Journal:  Clin Radiol       Date:  2020-04-07       Impact factor: 2.350

  2 in total
  3 in total

Review 1.  Global research trends in COVID-19 with MRI and PET/CT: a scoping review with bibliometric and network analyses.

Authors:  Nathaly Rivera-Sotelo; Raul-Gabriel Vargas-Del-Angel; Sergey K Ternovoy; Ernesto Roldan-Valadez
Journal:  Clin Transl Imaging       Date:  2021-08-14

Review 2.  Should I irradiate with computed tomography or sedate for magnetic resonance imaging?

Authors:  Michael J Callahan; Joseph P Cravero
Journal:  Pediatr Radiol       Date:  2021-03-12

3.  Changes in paediatric dental clinic after reopening during COVID-19 pandemic in Wuhan: a retrospective study.

Authors:  Jinghui Yang; Guobin Yang; Runze Jin; Guangtai Song; Guohua Yuan
Journal:  BMJ Open       Date:  2022-01-12       Impact factor: 2.692

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.