Literature DB >> 32561052

Evaluation of the energy resolution of a prompt gamma-ray imaging detector using LaBr3(Ce) scintillator and 8 × 8 array MPPC for an animal study of BNCT.

Keita Okazaki1, Hiroki Tanaka2, Takushi Takata3, Shinji Kawabata4, Kiyotaka Akabori5, Yoshinori Sakurai3.   

Abstract

To develop boron neutron capture therapy (BNCT), it is desired to measure 10B concentration and obtain a two-dimensional 10B distribution in animal studies. In this research, we develop a prompt gamma-ray imaging detector to measure 10B distribution using a 50 mm × 50 mm x 10 mm LaBr3(Ce) scintillator and a multi-pixel photon counter (MPPC). To measure a two-dimensional 10B distribution, the 478 keV gamma-ray emitted from 10B(n,α)7Li reaction should be measured with the discrimination from 511 keV background gamma rays in each MPPC. Furthermore, as a characteristic of the detector, it is necessary to investigate whether the 478 keV events individually incident on the MPPC can be measured in two dimensions. In this study, we evaluated the energy resolution and performed a two-dimensional distribution measurement using a thermal neutron beam and prompt gamma rays from a boron sample. This system was able to obtain energy resolution as full width at half maximum at 511 keV of 5.0 ± 0.2% in all MPPC pixels, better than the 6.5% energy resolution required to discriminate between 478 and 511 keV gamma rays. When the region of interest (ROI) was set up from -3σ to - σ (first ROI) and -3σ to the median (second ROI) for the Gaussian distribution of a 478 keV gamma-ray peak using a 6.25 ppm sample, the detector count rate of the 478 keV gamma rays was 0.03 and 0.11 cps, respectively, without a collimator. Moreover, the effect due to the overlapping 511 keV gamma ray peak was approximately 2.0% in the first ROI and approximately 3.2% in the second ROI. In addition, the counts of 478 keV gamma rays were visualized in two-dimensional.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  BNCT; Boron imaging; Boron neutron capture therapy; Gamma ray imaging; Prompt gamma ray imaging; Realtime

Year:  2020        PMID: 32561052     DOI: 10.1016/j.apradiso.2020.109214

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  1 in total

1.  Potentialities of High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma-Ray Measurements in BNCT.

Authors:  Leonardo Abbene; Fabio Principato; Antonino Buttacavoli; Gaetano Gerardi; Manuele Bettelli; Andrea Zappettini; Saverio Altieri; Natalia Auricchio; Ezio Caroli; Silvia Zanettini; Nicoletta Protti
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576