Literature DB >> 32560984

Evaluation of optimal size of illite adsorbent for 137Cs removal in contaminated artificial lake.

Jong Gil Park1, Weon Shik Han2, Sungwook Choung3, Jeonghwan Hwang1, Youn-Tae Kim4, Tae Kwon Yun1.   

Abstract

Since the Chernobyl and the Fukushima Daiichi disasters, contamination caused by radioactive accidents has attracted increasing attention. The present study evaluated immediate cleanup of 137Cs dissolved in surface water reservoir using an illite adsorbent, simulating an event of 137Cs contamination at Lake Paldang, South Korea. The study was conducted in two parts: (1) calculation of the residence time (tr) of illite adsorbent, and (2) evaluation of the adsorption time (ta) of illite adsorbent. tr was calculated based on physical properties (e.g., density, diameter, shape, and roughness) of the illite adsorbent at designated depth of surface water. Subsequently, ta was measured for 4 illite adsorbents (Korea01-Illite, Korea02-Illite, USA-Illite, and China-Illite) at 100 and 100,000 μg/L Cs, via kinetic adsorption experiment. Upon spraying of illite adsorbents with 50-150 μm diameter to locations where lake depth was between 6.5 m and 25.5 m, tr ranged from 0.132 to 3.300 h ta of 4 illite adsorbents was shorter than 0.6 and 2.5 h, for respective tests using 100 and 100,000 μg/L Cs. Based on the two characteristic times (tr and ta), the optimal particle diameter for the 4 illite adsorbents were evaluated at available lake depths in Lake Paldang. The study revealed that the USA-Illite is the efficient adsorbent at 100 μg/L Cs; in contrast, China-Illite could serve as the effective adsorbent at 100,000 μg/L Cs. Also, it was suggested that adsorbent efficiency had seasonal variations; tr was 2 h longer in winter than summer. In general, the study suggests that in the event of 137Cs contamination at Lake Paldang, Korea01-Illite is likely the best adsorbent to remove 137Cs due to its removal efficiency and accessibility from the illite deposit in Korea.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Adsorption time; Dissolved (137)Cs; Illite adsorbent; Immediate cleanup; Settling velocity

Year:  2020        PMID: 32560984     DOI: 10.1016/j.jenvman.2020.110739

Source DB:  PubMed          Journal:  J Environ Manage        ISSN: 0301-4797            Impact factor:   6.789


  1 in total

1.  Uptake of Radionuclides 60Co, 137Cs, and 90Sr with α-Fe2O3 and Fe3O4 Particles from Aqueous Environment.

Authors:  Natalya V Efimova; Alla P Krasnopyorova; Galina D Yuhno; Dmitry S Sofronov; Mirosław Rucki
Journal:  Materials (Basel)       Date:  2021-05-28       Impact factor: 3.623