Literature DB >> 3255801

Arterial pulsation and lymph formation in an isolated sheep hindlimb preparation.

J G McGeown1, N G McHale, K D Thornbury.   

Abstract

1. Lymph flow was measured by cannulating metatarsal lymphatics in the sheep hindlimb. The region was perfused with warmed, heparinized, oxygenated blood via the tibio-cranial artery cannulated just distal to the hock. Constant and pulsatile perfusion pressures were compared. A cuff was inflated over the metatarsals to maintain venous pressure at 20 mmHg. 2. The lymph flow rates during constant perfusion at 80 mmHg were comparable to control flows in intact metatarsal preparations and oedema (monitored by measuring tissue volume) did not accumulate. Flow records were similar to those obtained from anaesthetized animals, lymph being expelled by regular lymphatic contractions. 3. Pulsatile perfusion using 120/60 mmHg (systolic cuff cycle 0.25 s inflation, 0.5 s deflation) did not increase the rate of lymph flow. Increasing the pulse pressure to 100 mmHg (150/50 mmHg) produced a 20% increase in flow but this was not statistically significant. The cuff deflation time was also increased (1 s inflation, 1 s deflation) using 120/60 mmHg but this had little effect. 4. It may be concluded that arterial pulsation is not important for lymph formation in this preparation.

Entities:  

Mesh:

Year:  1988        PMID: 3255801      PMCID: PMC1190993          DOI: 10.1113/jphysiol.1988.sp017350

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


  13 in total

1.  The effect of blood vessel pulsations on lymph pressure in large lymphatics.

Authors:  R C WEBB; T E STARZL
Journal:  Bull Johns Hopkins Hosp       Date:  1953-12

2.  The role of external compression and movement in lymph propulsion in the sheep hind limb.

Authors:  J G McGeown; N G McHale; K D Thornbury
Journal:  J Physiol       Date:  1987-06       Impact factor: 5.182

Review 3.  Lymph formation and flow.

Authors:  P A Nicoll; A E Taylor
Journal:  Annu Rev Physiol       Date:  1977       Impact factor: 19.318

4.  The effect of intravenous adrenaline and noradrenaline infusion of peripheral lymph flow in the sheep.

Authors:  N G McHale; I C Roddie
Journal:  J Physiol       Date:  1983-08       Impact factor: 5.182

5.  New morphological evidence for a mechanism of lymph formation in skeletal muscle.

Authors:  T C Skalak; G W Schmid-Schönbein; B W Zweifach
Journal:  Microvasc Res       Date:  1984-07       Impact factor: 3.514

6.  Perfusion of the isolated rat hind limb. An analysis of the technique.

Authors:  A Bomzon; S G Naidu
Journal:  J Pharmacol Methods       Date:  1985-12

7.  Pressures associated with lymphatic capillary contraction.

Authors:  P A Nicoll; R D Hogan
Journal:  Microvasc Res       Date:  1978-03       Impact factor: 3.514

8.  Thoracic duct lymph flow during pulsatile and nonpulsatile extracorporeal circulation.

Authors:  I N Anabtawi; C E Womack; R G Ellison
Journal:  Ann Thorac Surg       Date:  1966-01       Impact factor: 4.330

9.  Hemodynamic effects of pulsatile and nonpulsatile flow.

Authors:  F Giron; W C Birtwell; H S Soroff; R A Deterling
Journal:  Arch Surg       Date:  1966-11

10.  Simultaneous measurement of pressure in the interstitium and the terminal lymphatics of the cat mesentery.

Authors:  G Clough; L H Smaje
Journal:  J Physiol       Date:  1978-10       Impact factor: 5.182

View more
  5 in total

1.  The relationship between lymphangion chain length and maximum pressure generation established through in vivo imaging and computational modeling.

Authors:  Mohammad S Razavi; Tyler S Nelson; Zhanna Nepiyushchikh; Rudolph L Gleason; J Brandon Dixon
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-08-04       Impact factor: 4.733

2.  Subatmospheric pressure in the rabbit pleural lymphatic network.

Authors:  D Negrini; M Del Fabbro
Journal:  J Physiol       Date:  1999-11-01       Impact factor: 5.182

Review 3.  Lymphatic Vessel Network Structure and Physiology.

Authors:  Jerome W Breslin; Ying Yang; Joshua P Scallan; Richard S Sweat; Shaquria P Adderley; Walter L Murfee
Journal:  Compr Physiol       Date:  2018-12-13       Impact factor: 9.090

Review 4.  Mechanical forces and lymphatic transport.

Authors:  Jerome W Breslin
Journal:  Microvasc Res       Date:  2014-08-05       Impact factor: 3.514

5.  Fluid pumping of peristaltic vessel fitted with elastic valves.

Authors:  Ki Tae Wolf; J Brandon Dixon; Alexander Alexeev
Journal:  J Fluid Mech       Date:  2021-05-11       Impact factor: 4.245

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.