Literature DB >> 32557969

Comparison of the Accuracy of Image Registration Methods for Merging Optical Scan and Radiographic Data in Edentulous Jaws.

Hyun-Wook Woo1, Hang-Nga Mai2, Du-Hyeong Lee1,2.   

Abstract

PURPOSE: The image registration of optical scans to radiographic images is essential for performing computer-guided implant surgery. This study aimed to evaluate the effect of different image matching conditions on the accuracy of image registration for computer-guided implant surgery in completely edentulous jaws.
MATERIALS AND METHODS: The optical scan image of a completely edentulous study model was registered to the respective cone-beam computed tomography data using three different image matching conditions: small point (SP), large point (LP), and entire surface (ES). For the SP and LP groups, gutta-percha markers (1.0 and 3.0 mm in diameter) were attached to a base template, and a radiopaque impression material was relined on the intaglio surface of template in the ES group. Image registration was performed by 20 operators in the images obtained from each group at an interval of 2 weeks (n = 20 in each group), and the registration accuracy was assessed by calculating the aligned position of the edentulous arch image. One-way analysis of variance with Tukey post hoc tests was used to compare the results among the groups (α = 0.05).
RESULTS: The mean registration error was significantly larger in the SP group (0.52 ± 0.19 mm) than in the LP group (0.29 ± 0.08 mm) and ES group (0.27 ±0.06 mm) (F = 24.689, p < 0.001). No difference was found between the LP and ES groups. The image matching discrepancy was more homogeneously distributed on the arch in the ES group than in the other groups.
CONCLUSION: The accuracy of image registration is affected by the size of the congruent area shown in the optical scan and radiographic images. The entire surface-based matching method is more accurate as compared to the small point-based matching method in the image registration for implant planning in full edentulous jaws.
© 2020 by the American College of Prosthodontists.

Entities:  

Keywords:  Image registration; accuracy; edentulous jaw; image matching; radiopaque

Mesh:

Substances:

Year:  2020        PMID: 32557969     DOI: 10.1111/jopr.13216

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  2 in total

1.  Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study.

Authors:  Xing-Yu Piao; Ji-Man Park; Hannah Kim; Youngjun Kim; June-Sung Shim
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

2.  Effects of Exposure Parameters and Voxel Size for Cone-Beam Computed Tomography on the Image Matching Accuracy with an Optical Dental Scan Image: An In Vitro Study.

Authors:  Hang-Nga Mai; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2021-06-10       Impact factor: 3.411