Jorge Bardina1, Laura G Rico1, Michael D Ward2, Jolene A Bradford2, Jordi Juncà1,3, Jordi Petriz1. 1. Functional Cytomics Group, Institut de Recerca contra la Leucèmia Josep Carreras (IJC), Campus ICO-Germans Trias i Pujol, Institut Germans Trias i Pujol (IGTP), Universitat Autònoma de Barcelona, UAB, Badalona, Catalonia, Spain. 2. Thermo Fisher Scientific, Eugene, Oregon. 3. Institut Català d'Oncologia, Hospital Germans Trias i Pujol (HGTiP), Badalona, Catalonia, Spain.
Abstract
Translational research has improved the diagnosis and follow-up of hematological diseases and malignancies. However, some classical diagnostics used for research and clinical practice that have remain practically unchanged for decades may be better addressed through advances in flow cytometry technology, whereby more precise measurements may be implemented in a straightforward manner. The current method for semiquantitative analysis of granulocytic alkaline phosphatase (GAP) activity is still based on observer-dependent color-intensity classification. Here, we describe a novel strategy for flow cytometric quantification of GAP activity in which staining and analytical flow cytometry facilitate the detection and quantification of subpopulations of leukocytes with different GAP activities. Our experiments demonstrate the potential of flow cytometry as a simple and highly sensitive approach for measuring GAP activity in unlysed whole blood. Notably, a comparison of flow cytometry and enzyme cytochemistry techniques showed that enzyme activity scores were not similar, indicating that results needs to be interpreted with caution, given that the enzyme-substrate binding affinities may differ, as well as the subjective evaluation of the intensity of the precipitated dye.
Translational research has improved the diagnosis and follow-up of hematological diseases and malignancies. However, some classical diagnostics used for research and clinical practice that have remain practically unchanged for decades may be better addressed through advances in flow cytometry technology, whereby more precise measurements may be implemented in a straightforward manner. The current method for semiquantitative analysis of granulocytic alkaline phosphatase (GAP) activity is still based on observer-dependent color-intensity classification. Here, we describe a novel strategy for flow cytometric quantification of GAP activity in which staining and analytical flow cytometry facilitate the detection and quantification of subpopulations of leukocytes with different GAP activities. Our experiments demonstrate the potential of flow cytometry as a simple and highly sensitive approach for measuring GAP activity in unlysed whole blood. Notably, a comparison of flow cytometry and enzyme cytochemistry techniques showed that enzyme activity scores were not similar, indicating that results needs to be interpreted with caution, given that the enzyme-substrate binding affinities may differ, as well as the subjective evaluation of the intensity of the precipitated dye.