Literature DB >> 32543402

Patient-specific modelling of stent overlap: Lumen gain, tissue damage and in-stent restenosis.

R He1, L G Zhao2, V V Silberschmidt1, Y Liu1, F Vogt3.   

Abstract

This paper investigates the effects of multiple stents, with and without overlap, on the outcome of stent deployment in a patient-specific coronary artery using the finite element method. Specifically, the objective of this study is to reveal the effect of stent overlap on lumen gain, tissue damage and in-stent restenosis in percutaneous coronary intervention. Based on intravital optical coherency tomography imaging, three-dimensional model of a specific patient's coronary artery was developed, with two constituent layers (media and adventitia) and plaque, using Mimics. Hyperelastic models with damage, verified against experimental results, were used to describe stress-stretch responses of arterial layers and plaque. Abaqus CAE was used to create the models for Resolute Integrity™ drug-eluting stents and tri-folded expansion balloons. The results showed that lumen gain was improved by the overlapping stents than a single stent after deployment; however, damage to the media layer was greater, promoting a higher rate of in-stent restenosis. Meanwhile, the lumen gain achieved with the non-overlapping stents was smaller than that with the overlapping ones, due to an increased recoiling effect. Also, non-overlapping stents induced more tissue damage and higher rate of in-stent restenosis than overlapping stents. With respect to long-term clinical outcomes, the study recommended the use of a single stent where possible or multiple stents with minimal overlaps to treat long or angulated lesions.
Copyright © 2020 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Arterial damage; Finite element; In-stent restenosis; Patient-specific artery; Stent overlap

Mesh:

Year:  2020        PMID: 32543402     DOI: 10.1016/j.jmbbm.2020.103836

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  2 in total

1.  Prospective, single-centre evaluation of the safety and efficacy of percutaneous coronary interventions following a decision tree proposing a no-stent strategy in stable patients with coronary artery disease (SCRAP study).

Authors:  Ludovic Meunier; Matthieu Godin; Géraud Souteyrand; Benoît Mottin; Yann Valy; Vincent Lordet; Christian Benoit; Ronan Bakdi; Virginie Laurençon; Philippe Genereux; Matthias Waliszewski; Caroline Allix-Béguec
Journal:  Clin Res Cardiol       Date:  2022-07-01       Impact factor: 6.138

2.  In-Stent Restenosis Progression in Human Superficial Femoral Arteries: Dynamics of Lumen Remodeling and Impact of Local Hemodynamics.

Authors:  Monika Colombo; Yong He; Anna Corti; Diego Gallo; Federica Ninno; Stefano Casarin; Jared M Rozowsky; Francesco Migliavacca; Scott Berceli; Claudio Chiastra
Journal:  Ann Biomed Eng       Date:  2021-04-29       Impact factor: 3.934

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.