Literature DB >> 32541998

[Determination of UV-327 and UV-328 in mouse plasma by high performance liquid chromatography].

M Q Zhu1, R Cui1.   

Abstract

OBJECTIVE: To establish a high performance liquid chromatography (HPLC) method for the determination of ultraviolet (UV) absorbers UV-327 and UV-328 in mouse plasma.
METHODS: N-hexane-acetone (volume ratio 1 ∶1) was added to a mouse plasma sample as the extraction solvent for vortex extraction, and the supernatant was dried at 50 ℃ with nitrogen. Thereafter the residue was redissolved with methanol, centrifuged and filtered. The separation was performed on a Waters SymmetryC18 column (250 mm×4.6 mm, 5 μm), and the concentrations of UV-327 and UV-328 in the mouse plasma were determined by HPLC with an UV detector. The elution was isocratic at a flow rate of 1.0 mL/min with a mobile phase composed of 100% methanol, and the UV detection wavelength was 340 nm. The retention time was used for qualitative analysis, and the internal standard method was used for quantitative analysis using UV-320 as the internal standard.
RESULTS: The calibration curves of UV-327 and UV-328 were linear with correlation coefficients of 0.999 7 over the concentration range of 0.05 to 10.0 mg/L. The limit of detection was 0.01 mg/L, and the limit of quantitation was 0.03 mg/L. The average recoveries at low, medium and high three concentrations (0.50, 1.00, 2.00 mg/L) in the mouse plasma were 91.7%-101.0% for UV-327, and 97.5%-103.9% for UV-328. The intra-day precisions (n=6) of UV-327 were 2.9%-6.6%, and 2.7%-7.4% for UV-328. The inter-day precisions (n=3) of UV-327 were 6.0%-9.3%, and 6.6%-8.6% for UV-328. The extraction recoveries of UV-327 were 98.8%-103.8%, and 99.8%-100.9% for UV-328. The measured relative deviations of UV-327 in the mouse plasma samples placed at room temperature for 6 hours and -40 ℃ for 15 days were 0.9%-3.5% and 7.4%-15.0%, and the measured relative deviations of UV-328 were 2.0%-4.3% and 2.1%-13.8%, respectively. The mouse plasma samples could be stored at room temperature for 6 hours at least and -40 ℃ for 15 days at three spiked concentration levels.
CONCLUSION: The method was simple and fast with high accuracy, precision and sensitivity, and could be applied to the determination of UV-327 and UV-328 in mouse plasma.

Entities:  

Keywords:  High performance liquid chromatography; Mouse; Plasma; UV-327; UV-328

Mesh:

Year:  2020        PMID: 32541998      PMCID: PMC7433428          DOI: 10.19723/j.issn.1671-167X.2020.03.030

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  13 in total

1.  Occurrence and concentrations of benzotriazole UV stabilizers in marine organisms and sediments from the Ariake Sea, Japan.

Authors:  Haruhiko Nakata; Sayaka Murata; Julien Filatreau
Journal:  Environ Sci Technol       Date:  2009-09-15       Impact factor: 9.028

2.  Multi-target determination of organic ultraviolet absorbents in organism tissues by ultrasonic assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry.

Authors:  Xianzhi Peng; Jiabin Jin; Chunwei Wang; Weihui Ou; Caiming Tang
Journal:  J Chromatogr A       Date:  2015-01-23       Impact factor: 4.759

3.  Environmental occurrence and risk of organic UV filters and stabilizers in multiple matrices in Norway.

Authors:  Katherine H Langford; Malcolm J Reid; Eirik Fjeld; Sigurd Øxnevad; Kevin V Thomas
Journal:  Environ Int       Date:  2015-03-30       Impact factor: 9.621

Review 4.  Are there other persistent organic pollutants? A challenge for environmental chemists.

Authors:  Derek C G Muir; Philip H Howard
Journal:  Environ Sci Technol       Date:  2006-12-01       Impact factor: 9.028

5.  Synthetic musk compounds and benzotriazole ultraviolet stabilizers in breast milk: Occurrence, time-course variation and infant health risk.

Authors:  Sunggyu Lee; Sunmi Kim; Jeongim Park; Hai-Joong Kim; Jeong Jae Lee; Gyuyeon Choi; Sooran Choi; Sungjoo Kim; Su Young Kim; Kyungho Choi; Sungkyoon Kim; Hyo-Bang Moon
Journal:  Environ Res       Date:  2015-05-15       Impact factor: 6.498

6.  Detection of benzotriazole UV stabilizers in the blubber of marine mammals by gas chromatography-high resolution mass spectrometry (GC-HRMS).

Authors:  Haruhiko Nakata; Ryu-ichi Shinohara; Sayaka Murata; Mafumi Watanabe
Journal:  J Environ Monit       Date:  2010-10-19

7.  A 52-week repeated dose toxicity study of ultraviolet absorber 2-(2'-hydroxy-3',5'-di-tert-butylphenyl)benzotriazole in rats.

Authors:  Mutsuko Hirata-Koizumi; Hidehiro Ogata; Toshio Imai; Akihiko Hirose; Eiichi Kamata; Makoto Ema
Journal:  Drug Chem Toxicol       Date:  2008       Impact factor: 3.356

8.  Gender-related difference in the toxicity of ultraviolet absorber 2-(3',5'-di-tert-butyl-2'-hydroxyphenyl)-5-chlorobenzotriazole in rats.

Authors:  Mutsuko Hirata-Koizumi; Takashi Matsuyama; Toshio Imai; Akihiko Hirose; Eiichi Kamata; Makoto Ema
Journal:  Drug Chem Toxicol       Date:  2008       Impact factor: 3.356

9.  Simultaneous determination of substituted diphenylamine antioxidants and benzotriazole ultra violet stabilizers in blood plasma and fish homogenates by ultra high performance liquid chromatography-electrospray tandem mass spectrometry.

Authors:  Zhe Lu; Thomas E Peart; Cyril J Cook; Amila O De Silva
Journal:  J Chromatogr A       Date:  2016-07-10       Impact factor: 4.759

10.  A 28-day repeated dose toxicity study of ultraviolet absorber 2-(2'-hydroxy-3',5'-di-tert-butylphenyl) benzotriazole in rats.

Authors:  Mutsuko Hirata-Koizumi; Nobuaki Watari; Daisuke Mukai; Toshio Imai; Akihiko Hirose; Eiichi Kamata; Makoto Ema
Journal:  Drug Chem Toxicol       Date:  2007       Impact factor: 3.356

View more
  1 in total

1.  Degradation of Benzotriazole UV Stabilizers in PAA/d-Electron Metal Ions Systems-Removal Kinetics, Products and Mechanism Evaluation.

Authors:  Dariusz Kiejza; Joanna Karpińska; Urszula Kotowska
Journal:  Molecules       Date:  2022-05-23       Impact factor: 4.927