| Literature DB >> 32537612 |
Abstract
We report the case of a patient who had a nasogastric tube inserted following cardiac surgery that was determined to be appropriately sited on chest X-ray. Following initiation of nasogastric feeding, however, the patient became acutely unwell. Subsequent computed tomography imaging demonstrated that the nasogastric tube had perforated through the posterior nasopharynx and passed through the mediastinum into the abdominal cavity. A laparotomy and washout was required, and following a prolonged intensive care stay with multiple further interventions, the patient ultimately survived to discharge. Pharyngeal wall perforation is a rare but serious complication of attempted nasogastric tube insertion. Risk factors include the need for repeated attempts and patients with an altered mental state. The appropriate steps in confirming the position of nasogastric tubes both clinically and radiologically are reviewed in the context of this rare and serious complication.Entities:
Keywords: critical care; gastrointestinal intubation; general surgery; patient safety; pharynx; radiology
Year: 2020 PMID: 32537612 PMCID: PMC7279965 DOI: 10.1002/anr3.12044
Source DB: PubMed Journal: Anaesth Rep ISSN: 2637-3726