Literature DB >> 32536526

Reliability of MRI tumor size measurements for minimal invasive treatment selection in small breast cancers.

W B G Sanderink1, M Caballo1, L J A Strobbe2, P Bult3, W Vreuls4, D J Venderink5, I Sechopoulos1, N Karssemeijer1, R M Mann6.   

Abstract

INTRODUCTION: Due to the shift towards minimal invasive treatment, accurate tumor size estimation is essential for small breast cancers. The purpose of this study was to determine the reliability of MRI-based tumor size measurements with respect to clinical, histological and radiomics characteristics in small invasive or in situ carcinomas of the breast to select patients for minimal invasive therapy.
MATERIALS AND METHODS: All consecutive cases of cT1 invasive breast carcinomas that underwent pre-operative MRI, treated in two hospitals between 2005 and 2016, were identified retrospectively from the Dutch cancer registry and cross-correlated with local databases. Concordance between MRI-based measurements and final pathological size was analyzed. The influence of clinical, histological and radiomics characteristics on the accuracy of MRI size measurements were analyzed.
RESULTS: Analysis included 343 cT1 breast carcinomas in 336 patients (mean age, 55 years; range, 25-81 years). Overall correlation of MRI measurements with pathology was moderately strong (ρ = 0.530, P < 0.001), in 42 cases (12.2%) MRI underestimated the size with more than 5 mm. Underestimation occurs more often in grade 2 and grade 3 disease than in low grade invasive cancers. In DCIS the frequency of underestimation is higher than in invasive breast cancer. Unfortunately, none of the patient, imaging or biopsy characteristics appeared predictive for underestimation.
CONCLUSION: Size measurements of small breast cancers on breast MRI are within 5 mm of pathological size in 88% of patients. Nevertheless, underestimation cannot be adequately predicted, particularly for grade 2 and grade 3 tumors, which may hinder patient selection for minimal invasive therapy.
Copyright © 2020. Published by Elsevier Ltd.

Entities:  

Keywords:  Breast cancer; Magnetic resonance imaging (MRI); Pathology; Pre-operative evaluation; Tumor size measurement

Year:  2020        PMID: 32536526     DOI: 10.1016/j.ejso.2020.04.038

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  2 in total

Review 1.  The accuracy of magnetic resonance imaging in predicting the size of pure ductal carcinoma in situ: a systematic review and meta-analysis.

Authors:  Ricardo Roque; Mariana Robalo Cordeiro; Mónica Armas; Francisco Caramelo; Filipe Caseiro-Alves; Margarida Figueiredo-Dias
Journal:  NPJ Breast Cancer       Date:  2022-06-29

2.  Evaluation of Breast Cancer Size Measurement by Computer-Aided Diagnosis (CAD) and a Radiologist on Breast MRI.

Authors:  Ji Yeon Park
Journal:  J Clin Med       Date:  2022-02-22       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.