Literature DB >> 32533828

Discriminative Ability and Reliability of Transesophageal Echocardiography in Characterizing Cases of Cardiac Device Lead Vegetations Versus Noninfectious Echodensities.

Merit P George1, Zerelda Esquer Garrigos1, Prakhar Vijayvargiya1, Nandan S Anavekar2, Sushil Allen Luis2, Walter R Wilson1,3, Larry M Baddour1,3, M Rizwan Sohail1,3.   

Abstract

BACKGROUND: Approximately one-third of cases of cardiovascular implantable electronic device (CIED) infection present as CIED lead infection. The precise transesophageal echocardiographic (TEE) definition and characterization of "vegetation" associated with CIED lead infection remain unclear.
METHODS: We identified a sample of 25 consecutive cases of CIED lead infection managed at our institution between January 2010 and December 2017. Cases of CIED lead infection were classified using standardized definitions. Similarly, a sample of 25 noninfected patients who underwent TEE that showed a defined lead echodensity during the study period was included as a control group. TEEs were reviewed by 2 independent echocardiologists who were blinded to all linked patient demographic, clinical, and microbiological information. Reported echocardiographic variables of the infected vs noninfected cases were compared, and the overall diagnostic performance was analyzed.
RESULTS: Descriptions of lead echodensities were variable and there were no significant differences in median echodensity diameter or mobility between infected vs noninfected groups. Among infected cases, blinded echocardiogram reports by either reviewer correctly made a prediction of infection in 6 of 25 (24%). Interechocardiologist agreement was 68%. Sensitivity of blinded TEEs ranged from 31.5% to 37.5%.
CONCLUSIONS: Infectious vs noninfectious lead echodensities could not be reliably distinguished on the basis of size, mobility, and general shape descriptors obtained from a retrospective blinded TEE examination without knowledge of clinical and microbiological parameters. Therefore, a reanalysis of criteria used to support a diagnosis of CIED lead infection may be warranted.
© The Author(s) 2020. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

Entities:  

Keywords:  cardiac implantable electronic device–associated lead infection; echodensities; noninfectious; transesophageal echocardiography; vegetation

Year:  2021        PMID: 32533828     DOI: 10.1093/cid/ciaa472

Source DB:  PubMed          Journal:  Clin Infect Dis        ISSN: 1058-4838            Impact factor:   9.079


  1 in total

1.  Risk of Cardiovascular Implantable Electronic Device Infection in Patients Presenting With Gram-Negative Bacteremia.

Authors:  Supavit Chesdachai; Larry M Baddour; M Rizwan Sohail; Bharath Raj Palraj; Malini Madhavan; Hussam Tabaja; Madiha Fida; Brian D Lahr; Daniel C DeSimone
Journal:  Open Forum Infect Dis       Date:  2022-08-25       Impact factor: 4.423

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.